  • Page 1 All In One Heat Pump For Domestic Hot Water Installation & Operation Manual All-In-One Type Air Source Heat Pump Water Heater Model: Eurosun-HPR-200L Eurosun-HPC-200L Eurosun-HPR-270L Eurosun-HPC-270L Thank you very much for purchasing our product, please keep this installation manual carefully and read this manual carefully before you install heat pump.
  • Page 2: Table Of Contents

    All In One Heat Pump For Domestic Hot Water NOTES Dear customers, Thank you for selecting our products! The manual is aim to let you learn more installation, operation and maintenance of heat pump and provides some important safe information for you. It’s quite required to carefully read the whole contents shown in this manual before you install and use heat pump, and please keep this installation manual carefully for purpose of future reference.
  • Page 3: Safety Precautions

    All In One Heat Pump For Domestic Hot Water Safety Precautions Please make sure you have read at least one chapter of safety precautions shown in the manual. This part provides quite important safe points for you and please operate it based on safety precautions. Warning 1.
  • Page 4 III conditions; All-pole disconnect switch), then the disconnect device must be incorporated into the fixed wiring according to the arrangement of wiring rules; 17. The minimum installation room area for products EUROSUN-HPR-200L and EUROSUN-HPC-200L is 69 square meters, and the minimum installation room area for products EUROSUN-HPR-270L and EUROSUN-HPC-270L is 42 square meters, unless the products are used entirely outside;...
  • Page 5 All In One Heat Pump For Domestic Hot Water 31. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 6: General Information

    All In One Heat Pump For Domestic Hot Water General Information I. Measurement Model Weight(kg) Dimension(mm,D×H) Power supply Water connection size Eurosun-HPR-200L φ620mm*1620mm 220V/ 50Hz/ 1 phase 3/4” Eurosun-HPC-270L φ620mm*1850mm 220V/ 50Hz/ 1 phase 3/4” Eurosun-HPR-270L Eurosun-HPC-270L External appearance...
  • Page 7 All In One Heat Pump For Domestic Hot Water III. Features All in one heat pump for sanitary hot water : 1. Has complete isolation between water and electricity, without electric shock problem, more safety; 2. No fuel tubes and storage, no potential danger from oil leakage, fire, explosion, and so on;...
  • Page 8: Refrigerant Circuit

    All In One Heat Pump For Domestic Hot Water Refrigerant circuit Compressor: R290, supplied by GMCC. Evaporator: Copper tube and aluminum fin type heat ex-changer. EXV: Electronic expansion valve, the opening is regulated according to the discharge air temperature of compressor. Fan: Centrifugal fan with three speeds.
  • Page 9: Specifications

    All In One Heat Pump For Domestic Hot Water Specifications Eurosun-HPR-270L Eurosun-HPR-200L Model Eurosun-HPC-270L Eurosun-HPC-200L Power supply 220V~240V/50HZ 220V~240V/50HZ Rated Input Power(Heat pump) 0.70KW 0.70KW Rated Input Current(Heat pump) 3.4A 3.4A Rated Heating Capacity(Heat pump) 2.82KW 2.82KW Rated Input Power(Resistance) 1.8KW...
  • Page 10: Parts Names

    All In One Heat Pump For Domestic Hot Water Parts Names NOTE All the pictures in this manual are for explanation purpose only. They may be slightly different from the heat pump water heater you purchased ( depend on the model ). Please refer to the real sample instead of the pictures of this manual.
  • Page 11 All In One Heat Pump For Domestic Hot Water 6. The noise and exhausting air don’t influence neighbors’ normal life; 7. The place has no combustible air to leak; 8. Easy to install connection pipe and electrical parts; 9. If heat pump installed in those metal parts of the building, electrical insulation must be done well and must comply with technical standard on electrical equipment.
  • Page 12 All In One Heat Pump For Domestic Hot Water for purpose of avoiding scratch and deformation; 4. Do not touch fan with your hands or other objects; 5. Do not move the heat pump at the angle of 75°. III. The Installation of Heat Pump 1.
  • Page 13 All In One Heat Pump For Domestic Hot Water...
  • Page 14 All In One Heat Pump For Domestic Hot Water IV. Products External Dimension Size Model Eurosun-HPR-200L 1570 1055 Eurosun-HPC-200L Eurosun-HPR-270L 1848 1278 Eurosun-HPC-270L...
  • Page 15: Pipe Line Connection

    All In One Heat Pump For Domestic Hot Water Pipe Line Connection I. Pipe Line Connection Diagram Water Quality Requirements PH value Total hardness Conductivity Sulphate ion Chlorine ion Ammonia ion 7~8.5 < 50ppm <200μV/cm(25℃) None < 50ppm None Sulfate ion Silicon Iron content Sodium...
  • Page 16 All In One Heat Pump For Domestic Hot Water III. Water Pipe Installation Instructions 1. Please don’t use iron pipe connect to heat pump, please use CPVC pipe,PPR pipe or PB pipe; 2. Please according to the drawing shows to install the water pipes,connectors etc.,if the ambient temperature is below 0 ℃, proper insulation must be taken for the water pipes;...
  • Page 17 All In One Heat Pump For Domestic Hot Water water overflows from water outlet, then inspect all pipeline and make sure have no water leakage. If found leakage, you need require it well and fill water into tank again; 7. When intake pressure is below 0.15MPa, a booster pump needed to be installed to connect with inlet water pipe for purpose of obtaining larger water capacity, which can make sure intake pressure is less than 0.15MPa;...
  • Page 18: Connection Of Electric

    Standard for electrical equipment; 1. Power Specification Item Leakage Manual switch Power The finest wire diameter protection Circuit breaker supply (mm2) Model device Size Eurosun-HPR-200L Ground Rated current (continuous Capacity Fuse wire length ≤ 30m) Eurosun-HPC-200L Below 30mA 220V/50Hz 0.1sec Eurosun-HPR-270L ≥20 ≥20A...
  • Page 19 All In One Heat Pump For Domestic Hot Water 2. Leakage Protection WARNING The external power supply box must be installed leakage protection device based on above figure for purpose of your safe; The equipment can be used unless you have confirmed ground wire reliably;...
  • Page 20 All In One Heat Pump For Domestic Hot Water 3. Electric Wiring Diagram...
  • Page 21: Method Of Application

    All In One Heat Pump For Domestic Hot Water Method of Application When using the unit, please operate to the following order: 1. Feeding water: when use the unit for the first time (or reuse it after the tank is empty ), before connect the unit with power, please make sure the tank is full of water.
  • Page 22 All In One Heat Pump For Domestic Hot Water 3. Water draining: before cleaning or moving the unit, please drain out the water in the water heater. The draining method as below picture: After the draining , please screw Close the inlet valve Open the outlet valve the nut of the drainage outlet;...
  • Page 23: Instruction Of Operation

    All In One Heat Pump For Domestic Hot Water Instruction of operation 1. Control system specifications (1) Operating condition ● Voltage:220V~±10%,50Hz±1Hz. ● Ambient temperature: -7~+43℃ ● Storage temperature: -20~+75℃ ● Relative humidity: 0~95%RH ● Temperature accuracy: ±1℃ (2) Main function ●...
  • Page 24 All In One Heat Pump For Domestic Hot Water 2. Wire controller and operation 1) Controller Instruction symbol status meaning Constantly bright heat pump is on Extinguished Heat pump is off Constantly bright at cooling mode Constantly bright at heating mode Constantly bright need repair Constantly bright...
  • Page 25 All In One Heat Pump For Domestic Hot Water Constantly bright Currently showing Celsius temperature display Show real time display Timer function is on display Currently in the on-time working hours Flashing set start time for working time display Currently at boot time, non-working time Flashing end time of current set working time Constantly bright /...
  • Page 26 All In One Heat Pump For Domestic Hot Water 1. Press at main interface to set the temperature. 2. Press and hold for 3 seconds in the power on/off state to enter the query state. down 3. In the query status, click to status query 4.
  • Page 27 All In One Heat Pump For Domestic Hot Water Under the main interface, press and hold for 10 “ ”+“ seconds to turn on/off the “sterilization” function manually (Parameter 66=1 is valid) ”+“ ” ”+“ Within 5 minutes after power-on, press and hold for 5 “...
  • Page 28 All In One Heat Pump For Domestic Hot Water setting value; press and Immediately release the “ ” button or no button operation in 5 seconds to exit the modification and return to the normal display state. When the parameter value is modified, it flashes for 2 seconds and then returns to the normal display state.
  • Page 29 All In One Heat Pump For Domestic Hot Water at this time. When the cooling/heating mode is switched, the compressor is allowed to start running after at least 3 minutes of stopping. 2.7 Forced speed heating: When following conditions are met at the same time: the controller is in the normal display state and heat pump is in the power-on state.
  • Page 30 All In One Heat Pump For Domestic Hot Water canceling the timing period. When all timed periods are cancelled, it is considered to be in an untimed return time period throughout the day. If the start time of a certain working period is greater than the end time, the end time is considered to be the next day.
  • Page 31 All In One Heat Pump For Domestic Hot Water 2.12 Key lock: When the controller is in the normal display state, the button is locked when there is no button operation for more than 60 seconds. Press any button at this time to unlock. 3.
  • Page 32 All In One Heat Pump For Domestic Hot Water icon flashes 3 times and the buzzer sounds for 3 seconds. Turn off the water pump and the “ ” icon goes out (if the timed water is set before, the “Back Pump” and “Timer” icons are displayed). During this process, press and hold the “cold and hot”...
  • Page 33 All In One Heat Pump For Domestic Hot Water After the pump has been on standby for 12 hours, it is forced to run for 1 minute. 3.6 High temperature sterilization control for Electric heater Manual sterilization mode: While the controller is in normal display state, press and hold the “M”+“∧”+“∨” button for more than 5 seconds at the same time, the heater symbol flashes to indicate that it enters the manual sterilization mode.
  • Page 34 All In One Heat Pump For Domestic Hot Water be higher than or equal to the exhaust high temperature protection value by 110℃ for 10 consecutive seconds, an high exhaust temperature alarm occurs and the compressor stops. At this time, controller shows high temperature fault alarm code "02E". When the exhaust temperature drops back to 90℃, the alarm is released and the normal temperature control function is restored.
  • Page 35 All In One Heat Pump For Domestic Hot Water return water temperature) When the water tank or ambient temperature sensor are faulty, electric heating operation is not allowed. “11E”, “12E”, “13E” ", "14E", "15E", "17E", "18E", "19E". are correspondingly displayed when the coil temperature sensor, ambient temperature sensor, exhaust temperature sensor, inlet water temperature sensor/tank temperature sensor, absorb temperature sensor, and outlet water temperature sensor/return water temperature sensor are faulty.
  • Page 36: Pilot Run Of Heat Pump

    All In One Heat Pump For Domestic Hot Water Pilot run of heat pump Please confirm the followings before pilot run of heat pump 1. The heat pump has been finished well; 2. Assemble pipe and wire are all correct; 3.
  • Page 37 All In One Heat Pump For Domestic Hot Water consumed during the process of protecting inner tank and extending use life. Under some water circumstance, anode rod and water can rise reaction, hot water will be quickly corroded and rise leakage when anode rod has been used up. We suggest check insulation materials every one year, if anode rod is used up, you can inquiry local server center or specific technical department to change a new one;...
  • Page 38 All In One Heat Pump For Domestic Hot Water 7. Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out.
  • Page 39 All In One Heat Pump For Domestic Hot Water connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that the apparatus is mounted securely. Ensure that seals or sealing materials have not degraded to the point that they no longer serve the purpose of preventing the ingress of flammable atmospheres.
  • Page 40: Charging Procedures

    All In One Heat Pump For Domestic Hot Water VII. Removal and evacuation When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be used. However, for flammable refrigerants it is important that best practice is followed since flammability is a consideration.
  • Page 41 All In One Heat Pump For Domestic Hot Water with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of recovered refrigerant.
  • Page 42 All In One Heat Pump For Domestic Hot Water calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release.
  • Page 43: After-Sale Service

    All In One Heat Pump For Domestic Hot Water After-sale Service If your hot water heater can not operate normally, please turn off the unit and cut off the power supply at once, then contact with our service center or technical department.