TABLE OF CONTENTS 1. DESCRIPTION OF THE APPLIANCE page 1.1 Description page 2 1.2 Functional elements of the appliance page 2 1.3 Control box page 3 1.4 Probe for temperature check page 3 1.5 Safety temperature sensor page 3 1.6 Connection cable to the electricity mains page 4 1.7 Specifications page 4...
The heating shower wall is made up of the following elements : 1. Panel of heating glass with profiles for wall fastening 2. Control box (outside the shower) 3. Towel bar 4. Electrical connection cable 5. Safety switch (not supplied by VISMARAVETRO)
1.3 Control box The control box is an integral part of the heating wall and must never be removed from the glass pane. The control panel includes the following buttons: 1. Button : turns the appliance on/off. 2. Button : lowers the temperature. 3.
Said cable must be connected by an electrical installer to the mains power supply upon the mandatory installation of a dedicated safety switch. (The safety switch is not supplied by Vismaravetro). 1.7 Specifications Working voltage: 220 - 240 V single phase, 50Hz.
2. ENCLOSURE INSTALLATION Before proceeding with the installation, make sure the position of the cable duct hole on the wall matches the height shown in the following drawing. 2.1 Assembly of the shower enclosure The heating wall is supplied with the control box already fixed to the glass. It is absolutely forbidden to disassemble or loosen the screws that fasten it to the glass panel.
3. WIRING 3.1 Inserting the cable and installing the towel bar The wiring must always be performed by qualified persons (electrical installer) in compliance with standards CEI 64 – 8 and subsequent revisions. In particular, it is necessary to comply with provisions CEI 64-8 / 701 “Special environments and applications : rooms including bathtubs or showers”.
3.2 Connection to the electricity mains WARNING: - It is mandatory for the power line to be always protected by an RCD ( residual current device ) with a tripping current not exceeding 30 mA. - The wall must have its own dedicated switch for turning the appliance on heating and off.
Page 10
3.2.2 Electrical connection in the presence of an external auxiliary contact (not supplied). wall is built so as to enable its turning on and off through remote control. For heating example, it enables the use of the contact of an external thermostat, the contact of a timer or a remote control.
4. TURNING THE APPLIANCE ON AND OFF After having completed the connection to the power mains, the electrical installer shall take care of turning on the appliance for the first time and perform the proper checks to ensure the correct operation of the appliance.
5. MAINTENANCE Before any cleaning, disconnect the heating wall from the electricity mains by placing the double- pole switch of the appliance and the main switch on the control panel in the “OFF” position 5.1 Cleaning the glass panel Please refer to the leaflet “use and maintenance” enclosed to the assembly instructions and included in the packing of the shower enclosure.
EC regulations regarding shower enclosures no. EN 14428 UNI regulations regarding tempered and layered glass no. UNI 12150 Vismaravetro Srl is ISO 9001/2000 certified regarding the quality system, no. IT 47724 Vismaravetro Srl is ISO 14000 certified regarding environmental management, no. IT 36812...
8. WARNINGS AND SAFETY GUIDELINES This instruction manual is an integral part of the product: make sure it always goes along with the product, also if the product is transferred to another owner or user or to another place. In case of its being damaged or lost, please request another copy from the Customer Assistance Service.
Page 15
FOR YOUR SAFETY YOU SHOULD REMEMBER THE FOLLOWING: WARNING: During use, avoid overheating, DO NOT COVER the heating wall with towels, bathrobes, clothes and whatever else might reduce the heat transfer from the glass to the environment. The heating wall must not be connected to the power mains by means of a plug. Do not hang on, pull or push the towel bar or the control box.
Need help?
Do you have a question about the R-SF78 and is the answer not in the manual?