Summary of Contents for smartmicro UMRR-12 TYPE 48
Page 1
RADIO RADIO EUT: FCC ID: FCC Title 47 CFR Part 15 Date of issue: 2023-08-21 UMRR-12 Type 48 B W34UMRR1230X2 Annex acc. to FCC Title 47 CFR Part 15 relating to s.m.s, smart microwave sensors GmbH UMRR-12 Type 48 B Annex no.
Page 2
RADIO EUT: FCC ID: FCC Title 47 CFR Part 15 Date of issue: 2023-08-21 UMRR-12 Type 48 B W34UMRR1230X2 User manual/ Functional description of the test equipment (EUT) V1.23 TÜV NORD Hochfrequenztechnik GmbH & Co. KG Tel.: +49 221 8888950 LESKANPARK, Building 10, Waltherstr.
USER MANUAL UMRR-12 TYPE 48 1 CONTENT Content ........................... 2 Abbreviations ........................3 Introduction ........................4 General description ......................5 Sensor description ....................5 Transmit Signal ......................5 General Performance Data ..................6 Software and Firmware Version ................8 Hardware ........................9 UMRR sensor ......................
USER MANUAL UMRR-12 TYPE 48 2 ABBREVIATIONS Analog-to-Digital Converter Analog Front-End Controller Area Network Digital Signal Processing; Digital Signal Processor EEPROM Electrically Erasable Programmable Read-only Memory FMCW Frequency Modulated Continuous Wave GPIO General Purpose Input Output MMIC Monolithic Microwave Integrated Circuit...
3 INTRODUCTION This document is a short documentation of the general purpose universal medium range radar (UMRR) UMRR-12 Type 48 radar sensor with type 48 antenna. Page 4 of 22 | 21. August 2023 Proprietary - This document may be subject to change without notice. The...
USER MANUAL UMRR-12 TYPE 48 4 GENERAL DESCRIPTION SENSOR DESCRIPTION The main task of the UMRR is the detection of any reflectors in the field of view, to measure the distance, the relative speed and the angle to the shortest reflector (and to other reflectors), to detect motion and to track (filter) the results over time.
USER MANUAL UMRR-12 TYPE 48 GENERAL PERFORMANCE DATA After power up or reset, the sensor readings are within specified performance within 60 seconds. At the first starting stage within 35 seconds, another waveform will be initialized before it switches to Waveform 6.
Page 9
USER MANUAL UMRR-12 TYPE 48 Table 4-1: General performance data Environmental Ambient Temperature -40 ... +80 degree C Shock Vibration Pressure / Transport altitude 0…10.000 Mechanical Weight 1290 Dimensions See 5.2 Housing Identification Antenna Identification DSP Board Identification General Power Supply 7 ...
USER MANUAL UMRR-12 TYPE 48 SOFTWARE AND FIRMWARE VERSION The software in UMRR-12 Type 48 radar processor has Version 6. Page 8 of 22 | 21. August 2023 Proprietary - This document may be subject to change without notice. The...
An example picture of a UMRR (universal medium-range radar) sensor (housing type 070707) is shown in the figures below. Figure 1: Housing type 070707 of UMRR-12 Type 48 front Page 9 of 22 | 21. August 2023 Proprietary - This document may be subject to change without notice. The...
Page 12
USER MANUAL UMRR-12 TYPE 48 Figure 2: Housing type 070707 of UMRR-12 Type 48 rear Page 10 of 22 | 21. August 2023 Proprietary - This document may be subject to change without notice. The information shall remain the exclusive property of s.m.s, smart microwave sensors GmbH.
USER MANUAL UMRR-12 TYPE 48 SENSOR DIMENSIONS All values given in mm. Figure 3: UMRR-12 Type 48 Housing 070707 dimensions (top view front) Page 11 of 22 | 21. August 2023 Proprietary - This document may be subject to change without notice. The...
Page 14
USER MANUAL UMRR-12 TYPE 48 Figure 4: Housing 070707 from the left side (left picture) and from the right side (right picture) Page 12 of 22 | 21. August 2023 Proprietary - This document may be subject to change without notice. The...
Page 15
USER MANUAL UMRR-12 TYPE 48 Figure 5: UMRR-12 Type 48 Housing 070707 dimensions (top view back) Page 13 of 22 | 21. August 2023 Proprietary - This document may be subject to change without notice. The information shall remain the exclusive property of s.m.s, smart microwave sensors GmbH.
USER MANUAL UMRR-12 TYPE 48 6 CABLES AND CONNECTORS SENSOR CONNECTOR The sensor connector is a 12-pin male (plug) circular bayonet type connector (water proof IP67, series LF10WBRB-12PD, manufacturer Hirose, Japan). A female counterpart (socket), e.g. LF10WBP-12S, is used to connect to the sensor. The pin numbering of the socket is shown in Figure 6 the pin description is given in Table 6-1.
For the RS485 data interface there is a 120 Ohms resistor on board of the sensor. A number of cable sets for initial operation and test purposes are offered by Smartmicro, to deliver a fast set-up of a sensor system. Among those preconfigured ready-to-run cables as well as cable stumps (pig tail cables or various lengths) which carry the connector on one side and open wires on the other.
USER MANUAL UMRR-12 TYPE 48 • Phase 2: This phase is used to compensate for negative edge phase error. For the UMRR sensor, this segment is programmable from 2 to 8 TIME QUANTA (TQ) and can be shortened by resynchronization.
USER MANUAL UMRR-12 TYPE 48 7 DESIGNATED USE The UMRR general purpose medium range radar is suitable for any application where the distance to and relative radial speed of large objects has to be measured. Typical applications are: Robotics: measure shortest distance to obstacle.
USER MANUAL UMRR-12 TYPE 48 8 COMPLIANCE DECLARATION OF COMPLIANCE FOR USA / FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 21
USER MANUAL UMRR-12 TYPE 48 The device have been evaluated under FCC Bulletin OET 65C (01-01) and found to be compliant to the requirements as set forth in CFR 47 Sections, 2.1093 addressing RF exposure from radio frequency devices. The device meet the applicable government requirements for exposure to radio frequency waves Page 19 of 22 | 21.
USER MANUAL UMRR-12 TYPE 48 FCC-LABEL An example of FCC-label is shown as following: Figure 9: Sample of FCC Label COMPLIANCE STATEMENT FOR CANADA / ISED 8.3.1 DECLARATION OF COMPLIANCE IN ENGLISH This device complies with Industry Canada licence-exempt RSS standard(s).
USER MANUAL UMRR-12 TYPE 48 8.3.2 DÉCLARATION DE CONFORMITÉ EN FRANCAIS Le present appareil est conforme aux CNR d’Industrie Canada applicables aus appareils radio exempts de licence. Léxploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisaeur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
To the extent permitted by applicable law, smartmicro disclaims (i) any and all liability arising out of the application or use of the product or the data contained herein, (ii) any and all liability of damages exceeding direct damages, including - without limitation - indirect, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of the suitability of the product for particular purposes.