ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL
ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON
Description
The Raptor addressable sounder is a large
weatherproof horn sounder suitable for
many indoor & outdoor applications.
It is available in red or white and has a
selection of 16 tones, selectable at the
control panel
Termination of field wiring is made to the
backbox for a clean first fix.
Connections - First Fix
The loop wiring connects to terminals in
the back box.
Earth
Not Used
Document No: GLT-271-7-2
Issue No: 008
INSTALLATION MANUAL
Final Fix
Backbox
Positive
In/Out
Negative
In/Out
Page 1
Set the device address (see address
setting)
Fix the BROWN sounder flying lead to
the POSITIVE terminal
Fix the BLUE sounder flying leads to
the RIGHT NEGATIVE terminal
Screw the sounder body to the
backbox.
Sounder Flying Leads
Sounder
Body
Author: NRP Jones
Date: 28/07/2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZRAP/R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zeta ZRAP/R

  • Page 1 ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON INSTALLATION MANUAL Final Fix Description • The Raptor addressable sounder is a large Set the device address (see address setting) weatherproof horn sounder suitable for many indoor &...
  • Page 2: Address Setting

    Protocol Usage The Raptor Sounder and sounder beacon work on the Zeta Fyreye II protocol only. The flasher (if fitted) can be triggered independently to the sounder, if the control panel sup- ports that function.
  • Page 3 One of 16 tones can be chosen for the alarm tone. Tone Description Pattern Frequency Rate 800 & 970 1Hz (500ms-500ms) BS Fire (Default Zeta tone) Alternating 800 & 970 2Hz (250ms-250ms) BS Fire Alternating 800 to 970...
  • Page 4 ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL Flasher Setting The Raptor has a 4 way dip switch for configuring the flasher. Switches 1 to 3 configure the flasher as shown below. Switch 4 is for future use. Setting 1 gives the specified flasher rating.
  • Page 5: Technical Data

    Check that loop is connected with correct polarity Check that sounder flying leads have been connected to the backbox. Check the panel is running the Zeta Fyreye MkII protocol Check panel`s actions (cause & effect) programming is correct. Sounder Is Not Operating...
  • Page 6 ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL Document No: GLT-271-7-2 Author: NRP Jones Page 6 Issue No: 008 Date: 28/07/2022...
  • Page 7 ADDRESSABLE RAPTOR SOUNDER & SOUNDER BEACON - INSTALLATION MANUAL Document No: GLT-271-7-2 Author: NRP Jones Page 7 Issue No: 008 Date: 28/07/2022...
  • Page 8: Other Information

    Type B: For Outdoor Use ZRAPB/R (W) Other Technical Data: See Doc: “Addressable Raptor Product file” held by the manufacturer Zeta Alarms Limited, 72-78 Morfa Road, Swansea SA1 2EN Document No: GLT-271-7-2 Author: NRP Jones Page 8 Issue No: 008...

This manual is also suitable for:

Zrap/wZrapb/rZrapb/w

Table of Contents