NOVO 15 DISCOVERY User Manual

Portable digital radiography systems

Advertisement

Quick Links

INNOVATIVE
COMPACT
RUGGED
Portable Digital Radiography Systems
NOVO User Manual
www. NOVO-DR.com
10 June 2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 15 DISCOVERY and is the answer not in the manual?

Questions and answers

Summary of Contents for NOVO 15 DISCOVERY

  • Page 1 INNOVATIVE • COMPACT • RUGGED Portable Digital Radiography Systems NOVO User Manual www. NOVO-DR.com 10 June 2016...
  • Page 2: Safety Warnings

    Warning - Do not use a damaged appliance! • Check all components upon receipt to assure damage has not occurred during shipment. In the event a component was damaged on delivery, contact NOVO DR immediately. Warning - Proper Installation • To guarantee your safety, ensure that the system is set up and connected as described in this User Guide.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS NOVO User Manual Table of Content 1. Safety Warnings ����������������������������������������������������������������������������������������������������������������������������������������������������������������� 2. Table of Content ���������������������������������������������������������������������������������������������������������������������������������������������������������������� 3. Discovery Operation Guide ������������������������������������������������������������������������������������������������������������������������������������������� • Disclaimer 3.1. Setting up a system – wired mode 3.2. Setting up a system – wireless mode 3.3.
  • Page 4 TABLE OF CONTENTS NOVO Touch Software 6.1. Status Icon 6.2. Detector Icon 6.2.1. Import Radiation Source 6.2.2. Import Detector 6.2.3. Export Detector 6.2.4. New Detector 6.3. Settings Icon 6.3.1. New Detector 6.3.2. Settings 6.3.3. Online/Offline 6.3.4. Detector Calibration 6.3.5. Open 6.3.6.
  • Page 5 6.7.1.1. Most Recent Tab 6.7.1.2. Unsaved Tab 6.7.1.3. Viewing Pane 6.7.1.4. Scroll Bar 6.7.2. Central Panel 6.7.2.1. Main Display Area 6.7.2.2. Search Box 6.7.2.3. Thumbnail Tab 6.7.2.4. Folders Tab 6.7.2.5. Sort By 6.7.2.6. Scroll Bar Info@NOVO-DR.com www.NOVO-DR.com [ 5 ]...
  • Page 6: Discovery Operation Guide

    USER MANUAL - NOVO 15 DISCOVERY | NOVO 15 DISCOVERY 4K | NOVO 22 DISCOVERY | NOVO 22 DISCOVERY 4K Discovery Operation Guide NOVO 15 DISCOVERY SYSTEM NOVO 15 DISCOVERY 4K SYSTEM NOVO 22 DISCOVERY SYSTEM NOVO 22 DISCOVERY 4K SYSTEM...
  • Page 7: Disclaimer

    USER MANUAL - NOVO 15 DISCOVERY | NOVO 15 DISCOVERY 4K | NOVO 22 DISCOVERY | NOVO 22 DISCOVERY 4K Disclaimer: Reading the radiation source manual and working according to the manufacture specifications guidelines is imperative before using NOVO’s systems. Furthermore, the usage of the radiation source must be according to the radiation regulations in the country in which you attempt to use the System.
  • Page 8 USER MANUAL - NOVO 15 DISCOVERY | NOVO 15 DISCOVERY 4K | NOVO 22 DISCOVERY | NOVO 22 DISCOVERY 4K Connect the Detector's Cable both to the Connect the Control Box and to the Detector. Communication Cable to the NOVO Hub.
  • Page 9 USER MANUAL - NOVO 15 DISCOVERY | NOVO 15 DISCOVERY 4K | NOVO 22 DISCOVERY | NOVO 22 DISCOVERY 4K Wireless Mode Turn on the Tablet using the power button. Battery Activate the Detector using the On/Off On/Off Wifi button on the side, confirm that status LED...
  • Page 10 USER MANUAL - NOVO 15 DISCOVERY | NOVO 15 DISCOVERY 4K | NOVO 22 DISCOVERY | NOVO 22 DISCOVERY 4K Carry the radiating source, Control Box and Detector to the inspected area, place the Detector behind the inspected object and place the source in front of it (~30"/~75cm...
  • Page 11: Shutting Down The System

    USER MANUAL - NOVO 15 DISCOVERY | NOVO 15 DISCOVERY 4K | NOVO 22 DISCOVERY | NOVO 22 DISCOVERY 4K Shutting Down the System Tap the “X” on the upper right corner of the software. A window with the “Cancel” or “Close” option will pop up on the screen .
  • Page 12: Charging The System Batteries

    USER MANUAL - NOVO 15 DISCOVERY | NOVO 15 DISCOVERY 4K | NOVO 22 DISCOVERY | NOVO 22 DISCOVERY 4K Charging the System's Batteries: The system consists of several batteries: • Control Box Battery • Detector Battery • Tablet Battery •...
  • Page 13 USER MANUAL - NOVO 15 DISCOVERY | NOVO 15 DISCOVERY 4K | NOVO 22 DISCOVERY | NOVO 22 DISCOVERY 4K Charging the Tablet's Battery: Confirm the connection between the Tablet's power cable and the power connection on board the Tablet.
  • Page 14: Rover Operation Guide

    USER MANUAL - NOVO 15 DISCOVERY | NOVO 15 DISCOVERY 4K | NOVO 22 DISCOVERY | NOVO 22 DISCOVERY 4K Rover Operation Guide NOVO 15 ROVER SYSTEM NOVO 22 ROVER SYSTEM...
  • Page 15: Disclaimer

    Reading the radiation source manual and working according to the manufacture specifications guidelines is imperative before using NOVO’s systems. Furthermore, the usage of the radiation source must be according to the radiation regulations in the country in which you attempt to use the System.
  • Page 16 USER MANUAL - NOVO 15 ROVER | NOVO 22 ROVER Connect the Detector's Cable both to the Connect the Control Box and to the Detector. Communication Cable to the NOVO Hub. Attention: Avoid connecting or disconnecting the Detector Cable from the Detector while the Control Box is On.
  • Page 17 USER MANUAL - NOVO 15 ROVER | NOVO 22 ROVER Wireless Mode Turn on the Tablet using the power button. Activate the Detector using the On/Off Battery button on the side, confirm that status LED On/Off Wifi is blinking for ~30 seconds and then that all three LEDs are lit constantly (Battery, Wifi and Status).
  • Page 18 USER MANUAL - NOVO 15 ROVER | NOVO 22 ROVER Carry the X-Ray source (attached to the Control Box) and the Detector to the inspected area. Place the Detector behind the inspected object and place the X-Ray source in front of the inspected object (~30"/~75cm when using the 15WS...
  • Page 19: Shutting Down The System

    USER MANUAL - NOVO 15 ROVER | NOVO 22 ROVER Shutting Down the System Tap the “X” on the upper right corner of the software. A window with the “Cancel” or “Close” option will pop up on the screen .
  • Page 20: Charging The System Batteries

    Battery On/Off Wifi Detector No indication No indication 4 Hours. Battery * If Detector is on, estimated charging time is 8 Hours. Status Attention: Disconnect the NOVO AC power cable before disassembling the system's modules. Info@NOVO-DR.com www.NOVO-DR.com [ 20 ]...
  • Page 21 USER MANUAL - NOVO 15 ROVER | NOVO 22 ROVER Charging the Tablet's Battery: Confirm the connection between the Tablet's power cable and the power connection on board the Tablet. Indication During Charging Indication when Fully Charged Estimated full charge...
  • Page 22: Patrol & Tactical Operation Guide

    USER MANUAL - NOVO 15 DISCOVERY | NOVO 15 DISCOVERY 4K | NOVO 22 DISCOVERY | NOVO 22 DISCOVERY 4K Patrol & Tactical Operation Guide P a t r o l B a c k p a c k p a c k...
  • Page 23 Reading the radiation source manual and working according to the manufacture specifications guidelines is imperative before using NOVO's systems. Furthermore, the usage of the radiation source must be according to the radiation regulations in the country in which you attempt to use the System.
  • Page 24 USER MANUAL - NOVO 15 PATROL | NOVO 22 PATROL | NOVO 15 TACTICAL Connect the remaining end of the Connect the USB Communication Cable to the USB Comm. connector of the USB Adapter and attach the USB Comm. Comm. Adapter to the Adapter to the back of the Tablet using the Tablet's USB socket.
  • Page 25 USER MANUAL - NOVO 15 PATROL | NOVO 22 PATROL | NOVO 15 TACTICAL Wireless Mode Turn on the Tablet using the power button. Battery On/Off Activate the Detector using the On/Off Wifi button on the side, confirm that status LED...
  • Page 26 USER MANUAL - NOVO 15 PATROL | NOVO 22 PATROL | NOVO 15 TACTICAL Carry the X-Ray source (attached to the Control Box) and the Detector to the inspected area, place the Detector behind the inspected object and place the X-Ray source in front of the inspected object (~30"/~75cm when using the 15WS...
  • Page 27: Shutting Down The System

    USER MANUAL - NOVO 15 PATROL | NOVO 22 PATROL | NOVO 15 TACTICAL Shutting Down the System Tap the "X" on the upper right corner of the software. A window with the "Cancel" or "Close" option will pop up on the screen.
  • Page 28: Charging The System Batteries

    USER MANUAL - NOVO 15 PATROL | NOVO 22 PATROL | NOVO 15 TACTICAL Charging the System's Batteries: The system consists of several batteries: • Control Box Battery • Detector Battery • Tablet Battery • Golden X-ray source Battery (optional)
  • Page 29 USER MANUAL - NOVO 15 PATROL | NOVO 22 PATROL | NOVO 15 TACTICAL Charging the Tablet's Battery: Connect the Tablet's power cable to both the power connection on board the Tablet and your power outlet. Indication During Charging Indication when Fully Charged...
  • Page 30: Urban Operation Guide

    Urban Operation Guide NOVO 15 URBAN SYSTEM...
  • Page 31 Reading the radiation source manual and working according to the manufacture specifications guidelines is imperative before using NOVO's systems. Furthermore, the usage of the radiation source must be according to the radiation regulations in the country in which you attempt to use the System.
  • Page 32 USER MANUAL - NOVO 15 URBAN Activate the Detector using the On/Off button on the side, confirm that status LED Battery is blinking for ~30 seconds and then that On/Off all three LEDs are lit constantly (Battery, Wifi Wifi and Status).
  • Page 33 USER MANUAL - NOVO 15 URBAN Carry the X-Ray source (attached with the Spark) and the Detector to the inspected area, place the Detector behind the inspected object and place the X-Ray source in front of the inspected object (at a distance of ~30"/~75cm from the 15WS detector).
  • Page 34: Shutting Down The System

    USER MANUAL - NOVO 15 URBAN Attention: In case you are experiencing an unstable or lose connection when working in wireless mode, you can improve reception by connecting the Wireless Ranger to the Tablet: If the Touch Software is running, Screw on the Wireless turn it off.
  • Page 35: Charging The System Batteries

    Status Attention: After disconnecting the NOVO Detector Charging cable you will need to shut down the detector. Press the Detector's On/Off button for ~5 seconds until the "Status" LED blinks before letting go of the button. Charging the Tablet's Battery:...
  • Page 36: Novo Touch Software

    NOVO Touch Software...
  • Page 37 A few simple gestures - tap, drag, scroll, swipe, and pinch, are all you need to operate your touch screen monitor. The following manual describes in detail the structure of NOVO’s Touch software and explains how to operate the various functions for an easy to use working experience.
  • Page 38: Status Icon

    USER MANUAL - NOVO TOUCH Top Bar (left) Status Icons The following table describes the meaning of each status icon: Device Icon Description Tablet battery level indication during charging - connected via cable to power Tablet Tablet Battery level indication - battery operation...
  • Page 39: Detector Icon

    USER MANUAL - NOVO TOUCH Detector Icon Touch and hold the Detector icon to open and select from a dropdown menu: Option Description Import Detector Import a definition File of a detector Export Detector Transfer a definition file to another computer or to an external storing device Import Radiation Source Import definition file of a new radiation source.
  • Page 40: Import Radiation Source

    This file can be imported to the software using this option and from any storage device. Import Detector “Import Detector” is used when you wish to import a definition file of a Detector to a specific NOVO Touch software.
  • Page 41: Export Detector

    The Export definition file is created from the NOVO Touch Software and it can be transfered to a storage device. Once created the specific definition file can be imported to the NOVO Touch software you are working on from the storage device.
  • Page 42: Settings Icon

    USER MANUAL - NOVO TOUCH Settings icon 1. Tap the Settings icon 2. Tap to select from the dropdown menu Set and reset system settings and personal preferences. Settings Go to Settings section for further information Defines system connection status: tapping the “Offline” button will transfer the system to Online/Offline “Offline”...
  • Page 43: Settings

    USER MANUAL - NOVO TOUCH Settings Go to Settings section for further information. Online/Offline This option enables you to disconnect or connect the system from within the software and with no need to shut it down(in battery mode the system will shut down).
  • Page 44: Detector Calibration

    USER MANUAL - NOVO TOUCH Detector Calibration The calibration section enables you to run a calibration procedure to the detector in order to create a definition file, the definition file is correcting the non uniformities and distortions from the taken image and creating an optimal image that is ideal for analysis.
  • Page 45 USER MANUAL - NOVO TOUCH Dark calibration When a fast calibration is needed you can run a dark calibration procedure. Although the image is not optimized, it is still quiet and uniformed and can give detailed information. Calibration with averaging...
  • Page 46: Open

    USER MANUAL - NOVO TOUCH Open Uploading images from a storage device to the software Gallery can be done using the “Open” option. The supported image file types (must be compressed in a zip file) are: “tif”, “tiff”, “jpg”, “jpeg”, “bmp”, “png”.
  • Page 47: Live

    USER MANUAL - NOVO TOUCH Live “Live” mode is allows us to view a live video of the inspected area. The “Live” mode can be used by the operator only when the “Lookout” module is being used for Dual Energy applications (see lookout section).
  • Page 48: About

    USER MANUAL - NOVO TOUCH About “About” option contains general information of the system such as software and system versions, company website, Email for general info, disclaimer and copyrights. 1. Select “About” from the settings dropdown menu 2. Get all software and system information Info@NOVO-DR.com...
  • Page 49 USER MANUAL - NOVO TOUCH X-Ray Screen “X-Ray Screen” is the main screen for controlling and activating the X-Ray procedure. Set exposure time or number of pulses depending on the radiating source Source Pulse / Time Bar you are using...
  • Page 50: Number Of Pulses/Exposure Time Bar

    USER MANUAL - NOVO TOUCH Number of pulses/Exposure Time Bar BWhen preparing to take a shot you may choose the number of pulses or exposure time values to be used with the source. Values will depend on the density of the material the inspected object is made of.
  • Page 51: Connection Status

    USER MANUAL - NOVO TOUCH Connection Status When initializing the software a communication process need to be established between the Tablet and the Control Box/Detector, the connection status window shows the connection procedure until system is ready for use. Once a connection is established you can grab X-Ray images, note that grabbing X-Ray image is disabled when system is initializing connection.
  • Page 52 USER MANUAL - NOVO TOUCH Connection established, ready for work Cable mode Ready status Wireless mode Ready status Info@NOVO-DR.com www.NOVO-DR.com [ 52 ]...
  • Page 53: Organic Detection

    USER MANUAL - NOVO TOUCH Organic Detection The Organic Detection option is used when you need to identify organic and inorganic materials in the inspected object. In order to do so you need to use the Lookout module which is attached to the Golden family X-Ray sources.
  • Page 54: Wireless

    USER MANUAL - NOVO TOUCH Wireless Wireless mode is used when you need to work without any cables (Full Wireless Mode) or to work partly with cables (Semi Wireless A Mode and Semi-Wireless B Mode). To select and verify wireless transmission mode, check the wireless button on your screen.
  • Page 55: Averaging

    USER MANUAL - NOVO TOUCH Averaging Averaging is a noise reduction process, It joins a number of consecutive images (no less than two) and displays a single refined averaged image. To activate Averaging – tap the “Averaging” button, a drop down menu will appear.
  • Page 56 USER MANUAL - NOVO TOUCH Averaging (continued) Tap to select a number of consecutive shots from the dropdown menu Or tap the calculator icon to display the calculator and type in a customized number of shots Tap OK when done...
  • Page 57: Detector

    USER MANUAL - NOVO TOUCH Detector Tap the dropdown Icon to select the type of Detector in use (the right type of detector with the suitable calibration file and the right serial number). Note: Make sure that the serial Number (in parenthesis) matches the number on the actual detector you are working with.
  • Page 58: Front Led

    USER MANUAL - NOVO TOUCH Front LED The Front Led dropdown icon controls the Control Box flashlight LEDs. There are two types of flashlight LEDs: White flashlight LED is used when illuminating the environment is needed in low light situations or when a safety beacon is being used during X-Ray activation (choosing this option can be done in the settings window).
  • Page 59: Safety Delay

    USER MANUAL - NOVO TOUCH Safety Delay Delaying the X-ray shot can be done using the Safety Delay module this option will allow to maintain a safety distance. To activate “Safety Delay” tap the “Safety Delay” button, a timer will appear, then tap the timer in order to set the desired delay time and tap OK, time delay will appear at the top left corner of the Safety Delay Button.
  • Page 60: Taking A Shot

    USER MANUAL - NOVO TOUCH Taking a Shot Once the system has established a connection (“Ready”) and all options are set, an X-Ray image can be taken. In order to grab an image tap the “Xray” button. A Pop up window will appear “Are you sure you wish to fire?”...
  • Page 61: Enhancing Screen

    USER MANUAL - NOVO TOUCH Enhancing Screen Manipulations can be done on received images or images from the Gallery using the NOVO image enhancing features. The Image enhancing buttons are very intuitive and easy to use, by using these enhancing features, the image can be optimized and maximum amount of details can be viewed.
  • Page 62: Left Bar

    USER MANUAL - NOVO TOUCH Left Bar Left Bar Leveling Greyscale leveling Genie Advanced propriety image processing tool Sharpen Image sharpening tool Emboss Transform grayscale to 3D tool Measure Accurate measuring tool More Additional NDT tools Note: You can touch and hold most of the icons on the Enhancing page this will open a dropdown menu will allow and access to additional enhancing options.
  • Page 63: Leveling

    You will now be able to view and examine a unique greyscale spectrum of a specific detail. Note: Displaying a 16 bit image, taken with NOVO’s Flat Panel detectors on a computer monitor requires the allocation of a brightness value to a 0-65,536 pixel value range. This is achieved by using a “linear translation”...
  • Page 64: Genie

    USER MANUAL - NOVO TOUCH Genie NOVO’s Genie is an advanced image processing tool comprising of NOVO’s unique proprietary algorithm and cutting edge tools. The Genie is designed to achieve the highest image quality and enhanced details at the shortest amount of time, while allowing a prompt yet comprehensive analysis.
  • Page 65: Sharpen

    USER MANUAL - NOVO TOUCH Sharpen The sharpening tool enhances details while helping to distinguish subtle nuances. A short tap on the “Sharpen” button intensifies the sharpening effect. Touch and hold the Sharpen button to open and select from a dropdown menu:...
  • Page 66 USER MANUAL - NOVO TOUCH Sharpen (continued) Long tap on the “Sharpen” button will open a drop down “Sharpen” options: Touch and hold to access additional Sharpening options Drag bars up or down to sharpen image manually Info@NOVO-DR.com www.NOVO-DR.com [ 66 ]...
  • Page 67: Emboss

    USER MANUAL - NOVO TOUCH Emboss The Emboss tool transforms the grayscale so that it has an overall 3D appearance. The tool facilitates the analysis process while making certain details, that are otherwise hidden, come out. Touch and hold the Emboss button to open and select from a dropdown menu:...
  • Page 68: Measure

    USER MANUAL - NOVO TOUCH Measure The Measure tool enables reliable general measuring options. The calibration function scales image to real size quickly while resolving the magnification factor and human eye limitations. Touch and hold the Measure button to open and select from a dropdown menu:...
  • Page 69 USER MANUAL - NOVO TOUCH Measure (continued) Long tap on the “Measure” button will open a drop down “Measure” options: Touch and hold to access additional measuring options Calibration Measurement In order to calibrate the length measurements of image details we can use the Calibration measurement tool.
  • Page 70 USER MANUAL - NOVO TOUCH Tool Bar Zoom in Obtain a magnified image Zoom out Scale down image Full screen View full screen image Rotate Revolve Image clockwise Region Focus on a specific area of interest within image Negative Reverse Image polarity Info@NOVO-DR.com...
  • Page 71: Zoom In

    The “Zoom In” Button magnifies the displayed image. Each tap increases zoom level by 10% (percentage level steps can be changed in the Settings window). Default zoom level is 73% for NOVO 15 detector and 47% for NOVO 22 detector. The current zoom level is displayed at the bottom right corner of your screen.
  • Page 72 USER MANUAL - NOVO TOUCH Zoom In (continued) Zoom In at 60% Zoom In at 80% Zoom In at 100% Zoom In at 140% Long tap on “Zoom In” button will open a drop down “Zoom In” options: Touch and hold to access additional “Zoom In”...
  • Page 73 USER MANUAL - NOVO TOUCH Zoom In (continued) Zoom Region To select a “Zoom In” region of interest, choose “Zoom Region”, tap the screen then pinch to define the desired area, a white rectangle will mark the borders of the selected region and then zoom in this region.
  • Page 74: Zoom Out

    USER MANUAL - NOVO TOUCH Zoom Out After you have zoomed in, you can zoom out to view the previous zoom level by tapping the “Zoom Out” button. Each tap scales image down by 10% (percentage level steps can be changed in the Settings). The current zoom level is displayed at the bottom right corner of your screen.
  • Page 75 USER MANUAL - NOVO TOUCH Zoom Out (continued) Long tap on “Zoom Out” button will open a drop down “Zoom Out” options: Touch and hold to access additional “Zoom Out” options Zoom in and out with your fingers: You can zoom in and zoom out by using two fingers gesture (same as on Smartphone).
  • Page 76: Full Screen

    USER MANUAL - NOVO TOUCH Full Screen The Full Screen function expands image to fill up your entire screen. Tap the “Full Screen” button to switch to a Full Screen mode. Tap the “Exit Full Screen” button to go back to previous screen.
  • Page 77: Rotate

    USER MANUAL - NOVO TOUCH Rotate The “Rotate” function changes image orientation. Each tap on the “Rotate” button rotates image 90 degrees clockwise. Long tap on the “Rotate” button opens a drop down options that enables also to flip image horizontally and vertically Tap to rotate image.
  • Page 78 USER MANUAL - NOVO TOUCH Rotate (continued) Long tap on the “Rotate” button will open a drop down “Rotate” options: Tap to rotate image. Each tap rotates image 90° clockwise Flip Image Horizontally Flip Image Vertically Info@NOVO-DR.com www.NOVO-DR.com [ 78 ]...
  • Page 79: Region

    USER MANUAL - NOVO TOUCH Region The “Region” function allows you to select a specific inner section within the image and apply enhancing tools to it. To select a region of interest, tap the screen then pinch to define the desired area. An Orange rectangle will mark the borders of the selected region.
  • Page 80: Negative

    USER MANUAL - NOVO TOUCH Negative The “Negative” function reverses image polarity; the lightest areas become the darkest, and vice-versa. To apply – Tap the “Negative” button. Note: to select or change polarity as a default go to Settings >Default Polarity...
  • Page 81: Right Bar

    USER MANUAL - NOVO TOUCH Right Bar Save Save original and processed images to Gallery Original Return to the original image saved in the Gallery Undo Cancel the last change made Redo cancel a previous “Undo” Delete Delete file from Gallery...
  • Page 82 USER MANUAL - NOVO TOUCH Save Images grabbed and processed images created can be saved to the Gallery (image database) by tapping the “Save” button. Once the “Save” button is tapped, the following “Image Information” screen will appear: Tap X to return previous screen...
  • Page 83 USER MANUAL - NOVO TOUCH Original Tap the “Original” button to revert to the original image saved in the Gallery. Note: Unless saved – your modifications will be permanently lost. The system does not display a warning message when the “Original” button is tapped.
  • Page 84 USER MANUAL - NOVO TOUCH Undo By tapping the “Undo” button you will cancel the last change made and restore image to its previous state. Tap “Undo” to cancel your last action Emboss button tapped once Undo Original image Redo By tapping the “Redo”...
  • Page 85 USER MANUAL - NOVO TOUCH Delete Tap the “Delete” button to permanently remove file from the Gallery. Upon tapping the button, a pop- up notification will appear and confirming the “Delete” action will be required. Once confirmed, the saved file will be permanently erased.
  • Page 86 USER MANUAL - NOVO TOUCH Annotations Tap the “Annotations” button to display the annotation toolbar. To save your annotations, tap the “Annotations“ button in oerdr to exit the annotations screen, then tap “Save”. “Annotations” toolbar overview: Tool What it does Tap the button then tap or pinch screen to select or adjust an existing annotation.
  • Page 87 USER MANUAL - NOVO TOUCH Annotations (continued) Tap to add text to your image. Text-color, font and Tap to add a straight arrow to the image. Arrowhead filling can be changed. Tap “Apply” when done should point towards the segment you wish to highlight...
  • Page 88 USER MANUAL - NOVO TOUCH Annotations (continued) Select Tap the “Select” Button then touch and hold screen to open and select from a dropdown menu with additional options. Touch and hold screen in an annotation free zone to open and select from a...
  • Page 89 USER MANUAL - NOVO TOUCH Annotations (continued) Select (continued) Touch and hold on an existing annotation: Touch and hold an existing annotation to open and select from a dropdown menu Option Description Delete annotation Delete annotation Delete all annotations Delete all annotations...
  • Page 90 USER MANUAL - NOVO TOUCH Annotations (continued) Select (continued) Annotation Properties: Option Description Line Change width and style of the line Mathematical actions between annotation and background behind the Rop2 annotation Fill Change fill style of rectangle or ellipse Font...
  • Page 91: Settings

    USER MANUAL - NOVO TOUCH Settings The “Settings” window enables adjusting basic functionalities of the software and the system according to the operators needs. The Setting options are set as default and are saved in every new initial operation. Zoom Step...
  • Page 92: Zoom Step

    USER MANUAL - NOVO TOUCH Zoom Step Tap to select or change your Zoom intervals settings - the ratio an image is scaled up or down with each tap on the zoom buttons. Tap the dropdown icon Tap to select or change...
  • Page 93: Language

    USER MANUAL - NOVO TOUCH Language Tap to select or change your Language settings. Tap the dropdown icon Tap to select or change your Language settings Measurement Units Tap to select your Measurement Units you want to use: Metric or Imperial.
  • Page 94: Multi Tablet

    USER MANUAL - NOVO TOUCH Multi Tablet Tap to enable or disable Multi Tablet mode. Enabling the Multi Tablet operation mode allows sharing real time images with additional distant viewer options such as another Tablet. When enabling Multi Tablet mode on all tablets an image share message will pop up on the secondary Tablet each time grabbing an image with the main Tablet is in process.
  • Page 95: Siren

    USER MANUAL - NOVO TOUCH Siren An Audible Siren is automatically activated during an X-ray shoot. By tapping the “Siren” button you can select the sound source – the Control Box, the Tablet or both. Tap the dropdown icon Tap to select...
  • Page 96: Control Device

    USER MANUAL - NOVO TOUCH Control Device Tap to choose which device you are working with: Control Box, Spark or Split Cable. Grab External Image Tap to shoot a still photo of the inspected object with your Lookout module. The photos can facilitate real time evaluation or can be saved for future analysis.
  • Page 97: Detector

    Tap the dropdown icon X-ray Source NOVO’s systems can operate with a large range of radiation sources: CP, Iridium, pulsed (including the entire Golden Engineering X-Ray sources) etc. The system can either work with synchronized sources or non-synchronized sources.
  • Page 98: Gallery

    USER MANUAL - NOVO TOUCH Gallery The “Gallery” window enables the operator to view all images saved in the software (new and old) and other images uploaded from an external memory device. The Gallery is divided into Folders, each folder can have one or multiple images.
  • Page 99: Left Panel

    USER MANUAL - NOVO TOUCH Left Panel Most Recent Tab View the most recent images taken Unsaved Tab View unsaved images Viewing Pane View Most Recent/Unsaved images, as selected Scroll Bar Scroll up and down the viewing pane Tap to select a...
  • Page 100: Central Panel

    USER MANUAL - NOVO TOUCH Central Panel Main Display Area View images Search box Search images according to a Letter or phrase Thumbnails Tab View images inside a folder Folders Tab View Folders Sort By Select a sorting option to view images...
  • Page 101 USER MANUAL - NOVO TOUCH Thumbnails tab and Folders tab Using the following tab gives the operator a way to switch between folders and their internal thumbnails. Tap to select a preferred viewing mode – Folders or Thumbnails Sort By “Sort By”...
  • Page 102: Image Options

    USER MANUAL - NOVO TOUCH Image Options Touch and hold on an image to open and select from a dropdown menu: Option Description Enhance Tap the “Enhance” option or double tap the image to go to the Enhancing screen Image Data...
  • Page 103 USER MANUAL - NOVO TOUCH Rename Enter a new file name. Tap “OK” when done Move Enter a new folder name or tap the dropdown menu icon to select an existing one. Tap “OK” when done Info@NOVO-DR.com www.NOVO-DR.com [ 103 ]...
  • Page 104 USER MANUAL - NOVO TOUCH Delete Tap “Yes” to permanently delete a saved file. Otherwise tap “NO” Share The “Share” button provides the option to save image/images to an external storage device therefore sharing information with another systems. The image/images can be saved in various formats such as: TIFF - 16bpp (*.tif), PNG –...
  • Page 105: Folder Options

    USER MANUAL - NOVO TOUCH Folder Options Touch and hold on a folder to open and select from a dropdown menu: Option Description Open Folder Display all images in the folder Rename Folder Rename folder Delete Folder Delete folder Share Save folder to an external storing device Info@NOVO-DR.com...
  • Page 106: Open Folder

    USER MANUAL - NOVO TOUCH Open Folder Open a folder to view all images located in the folder. Rename Folder Enter a new folder name. Tap “OK” when done Info@NOVO-DR.com www.NOVO-DR.com [ 106 ]...
  • Page 107: Delete Folder

    USER MANUAL - NOVO TOUCH Delete Folder Tap “Yes” to permanently delete a folder. Otherwise tap “NO” Share The folder “Share” button provides the option to save an entire folder as a zip file to an external storage device therefore sharing information with another systems.
  • Page 108 Portable Digital Radiography Systems NOVO DR Ltd. | Info@NOVO-DR.com | www. NOVO-DR.com...

This manual is also suitable for:

15 discovery 4k22 discovery 22 discovery 4k