Honeywell INNCOM DIRECT D1-528 Installation Instructions Manual
Honeywell INNCOM DIRECT D1-528 Installation Instructions Manual

Honeywell INNCOM DIRECT D1-528 Installation Instructions Manual

Table of Contents

Advertisement

Quick Links

INNCOM DIRECT D1-528
THERMOSTAT
About this Guide .................................................................. 2
General safety information ............................................... 2
Certification and Regulation ............................................ 2
FCC Part 15 compliant........................................................... 2
Introduction .......................................................................... 2
Features ....................................................................................... 2
Dimensions............................................................................ 3
System Architecture............................................................ 3
Specifications ....................................................................... 4
General ......................................................................................... 4
Electrical ...................................................................................... 4
Sensors ......................................................................................... 4
Environmental Specifications............................................. 4
Weight and Dimensions ........................................................ 4
Display .......................................................................................... 4
Communications ...................................................................... 5
Standards and Approvals ...................................................... 5
Installation ............................................................................ 6
Precautions................................................................................. 6
Before Installation ................................................................... 6
Restricting Access to Network............................................. 7
Location ................................................................................ 7
Mounting ..................................................................................... 7
Wiring Connections ................................................................. 8
Power and Actuator Connections ...................................... 9
Getting Started..................................................................... 11
Home Screen - User Interface............................................. 11
D1-528 LCD ............................................................................... 11
D1-528 Configuration Parameters ................................... 12
Initial Configuration ........................................................... 13
Set the Room ID ........................................................................ 13
Room Copy.................................................................................. 14
Setup HVAC Type ...................................................................... 15
Setup Fan Speed....................................................................... 15
Checking Functionality .......................................................... 16
Room Configuration Complete........................................... 16
Deploy the Property Key ........................................................ 16
Advanced Configuration .................................................... 17
Set the Room ID ........................................................................ 18
Room Copy.................................................................................. 18
Setup HVAC Type ...................................................................... 19
Setup Fan Speed....................................................................... 20
Tune Energy Savings............................................................... 20
dLt (UnOccupied Delta) .................................................. 21
® U.S. Registered Trademark
Copyright © 2024 Honeywell Inc. • All Rights Reserved
INSTALLATION INSTRUCTIONS
Uot (Unoccupied Time)................................................... 21
UrS (Unrented Setback).................................................. 22
Urt (Unrented Time after Unoccupied)..................... 22
Pan ID (PAn) ............................................................................... 23
RF Channel (rF)......................................................................... 23
Ping Device (Pn6)..................................................................... 24
Contractor Mode (Ctr) ............................................................ 24
Limited Energy Management Mode LEn ....................... 25
PIR Motion Sensor Test (Plr)................................................ 25
Door Test (dor)........................................................................... 26
Window Test (Uln) .................................................................... 26
Measured Room Humidity (rH) .......................................... 26
Run Menu Parameters rUn .................................................. 27
Address Parameter (Adr) ...................................................... 32
IO Map Parameter (Io)............................................................ 33
Replacing D1-528................................................................ 34
Factory Boot the D1-528 ................................................... 35
Troubleshooting................................................................... 36
31-00721-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INNCOM DIRECT D1-528 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Honeywell INNCOM DIRECT D1-528

  • Page 1: Table Of Contents

    Room Copy.................. 18 Setup HVAC Type ..............19 Setup Fan Speed............... 20 Tune Energy Savings............... 20 tt (Selectable target temperature range) ....20 dLt (UnOccupied Delta) ..........21 ® U.S. Registered Trademark 31-00721-01 Copyright © 2024 Honeywell Inc. • All Rights Reserved...
  • Page 2: About This Guide

    D1-528 thermostat is a half-wave rectifier device. This Guide provides information about the Installation If we connect it with another half-wave rectifier details of the INNCOM Direct D1-528 thermostat to the device or use the same transformer, INNCOM D1- system integrator, technicians, and end-users. All the...
  • Page 3: Dimensions

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE DIMENSIONS 4.87 inches 4.87 inches (123.84 mm) (123.84 mm) 1.18 inches 1.18 inches 4.7 inches 4.7 inches (30 mm) (30 mm) (119.84 mm) (119.84 mm) Fig. 1 Dimensions SYSTEM ARCHITECTURE REMOTE BUILDING MANAGER IP Ethernet...
  • Page 4: Specifications

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE SPECIFICATIONS Table 3 Sensors Specifications Parameter Description General PIR (motion) 120° View Angle, 10 M line of sight Table 1 General Specifications Lux (ambient light) Gamma Value 0.7. Spectral Parameter Description response 550-650 nm...
  • Page 5: Communications

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE Communications Standards and Approvals Table 7 Communications Specifications Table 8 Standards and Approvals Parameter Description UL 873, CAN/CSA C22.2 N°24, file #202540 Wireless ZigBee RF, Deep Mesh FCC ID: GTC202150TXR Communications IC ID: 1609A-202150TXR...
  • Page 6: Installation

    Warning By using this Honeywell literature, you agree that Important Safety Information and Honeywell will have no liability for any damages arising from your use or modification to the literature. You will Installation Precautions defend and indemnify Honeywell, its affiliates, and...
  • Page 7: Restricting Access To Network

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE guidance to mount it in a neutral location. The cost of 7. Check the ratings given in the instructions and on the poor thermostat placement is high, both in loss of product to make sure the product is suitable for your guest comfort and unnecessary energy costs.
  • Page 8: Wiring Connections

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE 1. Loosen the two screws from the base of the box. Plug the 6-pin low voltage harness onto the D1- D1-528 thermostat but don't remove them. 528 thermostat low voltage comm. / device connec- tion header.
  • Page 9: Power And Actuator Connections

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE Table 10 24VAC Harness (INNCOM P/N 62-1464 R) Color Code, Pinout, and Typical Functions Color Typical Function 24 VAC power, valve / fan control wiring from HVAC Violet Fan Power equipment Orange Low Fan...
  • Page 10 INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE D1-528 HAC D1-528 HAC Type set to 3 Type set to 9 D1-528 HAC Type D1-528 HAC Type set to 5, 6 or 12 set to 10 or 11 D1-528 HAC Type set to 7 or 8...
  • Page 11: Getting Started

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE GETTING STARTED Table 11 D1-528 Thermostat User Interface Parameter Description Home Screen - User Interface D1-528 The right 2 dots will always be The D1-528 thermostat user interface contains Communicat displayed when the D1- 528 is...
  • Page 12: D1-528 Configuration Parameters

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE D1-528 Configuration Parameters Table 12 D1-528 LCD details The D1-528 has several parameters that can be used to Sr No Parameter Name configure, test and troubleshoot the D1-528. The below Balcony, Window, Lanai: By default the table lists the available parameters in the D1-528.
  • Page 13: Initial Configuration

    To control or view the operation of the D1-528 in a Room Id room from RBM, you must have the Niagara service running on a PC or Honeywell JACE controller and the D-578 installed and configured from Niagara Workbench EasyOnBoard feature.
  • Page 14: Room Copy

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE NOTE: NOTE: Press the POWER button to cycle between the HI, LOW and MED values. 7. Press DISPLAY to store the value, when the desired Room ID is defined. ºF ºF ºC ºC The D1-528 will beep when the value is stored and the new Room ID number scrolls across the display.
  • Page 15: Setup Hvac Type

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE Setup HVAC Type Setup Fan Speed After the room id is set, press the UP/DOWN arrow FAn appears on the D1-528 to set the desired fan speed button to skip rCp, HAC will appear to set the desired after the HVAC type is set..
  • Page 16: Checking Functionality

    D-578, or powered via PoE (power over ethernet) if the D-578 Edge Router has been installed and the network switch supports PoE. configured , you can open and log into the Honeywell The D-578 has 2 communication channels. Remote Building Manager (RBM) site for your installation and see the rooms online.
  • Page 17: Advanced Configuration

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE ADVANCED CONFIGURATION The D3 Red LED on the D-578 will blink rapidly indicating it is in key distribution mode. The D1-528 has a Service Parameter mode with several The D-578 will begin to broadcast its unique property parameters that can be used to configure, test and key.
  • Page 18: Set The Room Id

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE Table 16. Service Parameter 7. Press POWER to continue. The last 2 digits of the Room ID will be displayed. 01 Parameter Function and LOW will appear. 8. Press the UP/DOWN arrow button to set the value Door Sensor Test (range is 0-99).
  • Page 19: Setup Hvac Type

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE • If no reply is received from the configured 2. Press the UP/DOWN arrow button and select HAC D1-528 after 60 seconds, the D1-528 will beep parameter. and display E11 as error code indicating it never received a reply to the pings.
  • Page 20: Setup Fan Speed

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE Setup Fan Speed For example, if you have selected HVAC Type 1 FCU-4, Fan speed options 1-Low, 2 -Low/High and 3 – The Fan speed is normally set when the D1-528 is Low/Med/High will be available.
  • Page 21: Dlt (Unoccupied Delta)

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE 3. Press the DISPLAY button. V and the current selected dLt value will be Table 19 Selectable target temperature range displayed. 1 - Normal is the default value. 4. Press the UP/DOWN arrow button to select the Parameter desired dLt value 1,2 or 3 as per the below table.
  • Page 22: Urs (Unrented Setback)

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE UrS (Unrented Setback) 1. Press and hold for 4 seconds to enter into service mode. The Unrented Setback (UrS) parameter allows the 2. Press the UP/DOWN arrow button and select Uot selection of Normal, Aggressive or Minimal savings parameter.
  • Page 23: Pan Id (Pan)

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE 1. Press and hold for 4 seconds to enter into service 2. Press the UP/DOWN arrow button and select PAn mode. parameter. 2. Press the UP/DOWN arrow button and select Urt parameter. ºF ºF ºC ºC...
  • Page 24: Ping Device (Pn6)

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE 410E - Read Major Version 410F - Read Minor Version 4145 - Read AGC Level. This will typically be 0. You need not care about the values that appear. What is important is that you see the reply values appearing and the D1-528 beeping.
  • Page 25: Limited Energy Management Mode Len

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE c. Press the F/C button. mode will automatically be disabled. If the room gets Str (store) will be displayed. unrented during this time, LEM mode will be dis- abled. d. Press DISPLAY to store the change.
  • Page 26: Door Test (Dor)

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE 4. Walk around the room and if your motion is detected report balcony position and that has been bound by the D1-528 motion sensor, the D1-528 will beep to the same Room ID, PAN ID and RF Channel as and increase the displayed value.
  • Page 27: Run Menu Parameters Run

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE Run Menu Parameters rUn Table 24. Run parameters The D1-528 has Run parameters that let you reset or Parameter Value Function reboot the D1-528 and perform a range of in room tests. The PIR, Door, Window tests can also be performed as P5 Address Trace.
  • Page 28 INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE Using the rUn menu: bL 2--- 0--- 2--- 0 IrA 2--- 1--- 0 ---0 1. Press and hold for 4 seconds to enter into service CbL 2--- 0 ---1--- 2 mode. APP 2--- 0--- 2--- 0 2.
  • Page 29: Eer - Read And Display Nvram Of The D1-528

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE 2. Press the DOWN arrow button to select rUn As an example, you need to read a PC502.4G (address parameter. 216) in a room and make sure it does NOT have its Room Gateway related P5 servers enabled. You don’t 3.
  • Page 30: 6R.a - Cbl32 Registry Group 9 Thermo/Hvac Editor

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE 2. Press the DOWN arrow button to select EEr If you want to view and edit/change a NVRAM memory parameter. location in the D1-528, you need to first enable elevated access for this by executing rUn Parameter 31 with Value 41: 1.
  • Page 31 INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE 2. Press the DOWN arrow button to select 6r.A 5. Press the UP/DOWN arrow button to select the parameter. desired 9:X Key. For example, if you want to view 9:1 Occupancy, change the displayed value to 1.
  • Page 32: Address Parameter (Adr)

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE 8. If you want to change the value, use the UP/DOWN If the target received the command, it should adopt arrow buttons to select the desired value, then press the defined settings and address and RESET. On DISPLAY.
  • Page 33: Io Map Parameter (Io)

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE IO Map Parameter (Io) A “Reverse Bind” is used for these devices where you initiate configuration from the target device by pressing Use the Io parameter to activate an IO Map in a target a button to make the device send a Bind Request.
  • Page 34: Replacing D1-528

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE • For any CBL32 device, press a button on the device 2 times quickly (Tap-Tap), then press the button for 4-7 seconds to accept the Bind. The CBL32 device should RESET and broadcast a “0x00031” Sound Buzzer VFI. If the D1-528 receives this it will beep as feedback that the bind was successful.
  • Page 35: Factory Boot The D1-528

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE FACTORY BOOT THE D1-528 If you look at the lower right corner of the D1-528 display, there will be NO communication Dots present immediately after the D1-528 started up. But once the NOTE: D1-528 has received the Property Key and has started...
  • Page 36: Troubleshooting

    INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE TROUBLESHOOTING Error/Trouble condition Probable cause Solution • Verify the 10 pin harness is fully connected/plugged into the 10 pin connector on the back of the D1-528. • Verify 24VAC is present/available on the HVAC unit low voltage interface terminal R (24VAC) and C (Common).
  • Page 37 INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE E11 Error code while The D1-528 in the room you are trying • Check if the correct Room ID is performing a Room Copy to copy from is not powered, or is defined for the Copy From D1-528...
  • Page 38 INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE E12 Error code while The room copy started (so the copy to • The copy from D1-528 is installed too performing a Room Copy D1-528 established a connection with far from the copy to D1-528, or there...
  • Page 39 Honeywell makes no representations or warranties with respect to this document. In no event shall Honeywell be liable for technical or editorial omissions or mistakes in this document, nor shall it be liable for any damages, direct or incidental, arising out of or related to the use of this document. No part of this document may be reproduced in any form or by any means without prior written permission from Honeywell.