• ELECTRIC EXTERNAL MOTOVIBRATORS
EN
MVE
CM
C
US
Intertek
II 3 D
CLASS II DIV.2
CM
C
US
Intertek
PN: 10-10108
AIRMATIC
airmatic.com |
215.333.5600
| infocenter@airmatic.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OLI MVE and is the answer not in the manual?

Questions and answers

Summary of Contents for AIRMATIC OLI MVE

  • Page 1 • ELECTRIC EXTERNAL MOTOVIBRATORS Intertek II 3 D CLASS II DIV.2 Intertek PN: 10-10108 AIRMATIC airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 2 6 POLES........................... TAB.46  TAB.48 8 POLES............................ TAB.49  TAB.51 10 POLES..........................TAB.52 MICRO MVE..........................TAB.53 MICRO MVE - 1Ph......................... TAB.54 ADJUSTING THE MASSES....................TAB.55  TAB.57 TIGHTENING TORQUES....................... TAB.58 HANDLING..........................TAB.59  TAB.60 AIRMATIC airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 3 TECHNICAL CATALOGUE Intertek II 3 D CLASS II DIV.2 Intertek AIRMATIC airmatic.com | | infocenter@airmatic.com 215.333.5600...
  • Page 4 However, the operators must follow the safety standards imposed by the regulations in force. Possible modifications of the safety standards that may occur shall be transposed and implemented. The latest version of the present Manual is available on the www.olivibrator.com website. AIRMATIC airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 5 - Class II DIV.2 according to the article NEC 500.5 of the National Electrical Code. The user shall make sure that the working place inside of which the electric vibrator is to be installed was properly set in safety conditions from an explosion risk point of view. AIRMATIC airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 6 Light the area that surrounds the electric vibrator by supplying, for instance, the operators with electric torches suitable for: - Zone 22 cat. II 3 D for ATEX environments. - Class II Div.2 (NEC 500.5) AIRMATIC airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 7: Warranty

    Possible damages or missing items has to be immediately communicated in writing to the Manufacturer, countersigned by the carrier. The products under warranty to be returned for repairs has to be shipped in FREE DESTINATION at our location. AIRMATIC airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 8 If the electric vibrator operates in different conditions with materials different from the previous ones check the compatibility of such use on the basis of the indications given at Chapter 1.3 - INDICATIONS FOR USE. AIRMATIC airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 9 INSTALLATION OPERATION AND MAINTENANCE Intertek II 3 D CLASS II DIV.2 Intertek AIRMATIC airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 10 - - - - - - - (B1) (B1) MODEL MVE Fc.(Kg) Fc.(Lb) MODEL MVE Fc.(Kg) Fc.(Lb) Cos φ Cos φ CAP. CAP. Duty S1 CL.F Ta 40°C Duty S1 CL.F Ta 40°C Fig.2 AIRMATIC M.10 airmatic.com | | infocenter@airmatic.com 215.333.5600...
  • Page 11: Shipping And Packaging

    If the damages are not claimed immediately on receipt of the goods, your request for compensation may not be accepted. The installer is liable for the proper disposal of the packaging according to the legislation in force. AIRMATIC M.11 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 12: Installation

    - The fixing bolts of the electric vibrator and the weldings of the reinforcement beadings or plates. - The anchoring cable or chain. - The electric supply cables. Fig.4a ≥ØS max 0.25mm max 0.01 in Fig.3 Fig.4 Fig.4b Fig.5 Fig.6 AIRMATIC M.12 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 13: Electrical Connections

    - Do not forget to fix the earthing cable (compulsory connection) - Close de cover by applying the gasket and tighten the cable gland so as the power cable is perfectly blocked. (Fig.11) AIRMATIC M.13 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 14 II 3 D CLASS II DIV.2 Intertek M. 14 EARTHING CONNECTION Junction box nuts tightening torque screw ft*lb 1.17 0.87 EQUIPOTENTIAL 1.95 1.45 CONNECTION 2.92 2.17 Fig.7 Fig.8 Fig.10 Fig.9 Fig.11 AIRMATIC M.14 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 15 MVE 41/3 3PH - 230V 50Hz MVE 6/3 1PH - 230V 50Hz MVE 41/3 3PH - 400V 50Hz MVE 41/3 3PH - 460V 60Hz CAVO CAVO CAVO condensatore GIALLO/VERDE VERDE(solo USA) GIALLO/VERDE GIALLO/VERDE VERDE(solo USA) VERDE(solo USA) AIRMATIC M.15 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 16 P E= Earthing connection Q = General switch F = Fuses PTC = PTC E1-E2 = Thermistor control devices motor 1 / motor 2 STP = Shut- down button STR = Start- up button M W1 AIRMATIC M.16 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 17 PE = Earthing connection Q = General switch F = Fuses PTC = PTC E1-E2 = Thermistor control devices motor 1 / motor 2 STP = Shut- down button STR = Start- up button AIRMATIC M.17 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 18 - When this operation was carried out on both sides, replace the covers and fix them using the same screws and washers ensuring that gaskets (OR) are properly placed on their seat. - Check the tightening torques to be used in section TAB page TAB.58 Fig.1 AIRMATIC M.18 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 19: Maintenance

    All electric vibrators are originally lubricated in the Factory. The electric vibrators that use ball bearings (pre-lubricated and shielded) doesn’t require lubrication. For the versions using roller bearings it is envisaged the grease replacement after 5000 working hours if the AIRMATIC M.19 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 20 Clean only with a moist cloth. The frequency of the cleaning operations is directly related to the nature of the product handled and to the equipment in which the electric vibrator is installed. Do not use high pressure water jet to clean the electric vibrator. AIRMATIC M.20 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 21 The surface temperature of the electric vibrator exceeds the burn threshold. There is a burning hazard. The external surface of the electric vibrator can’t be touched during normal operation; in case of maintenance, it is necessary to wait for the temperature to lower under 55°C (130°F). AIRMATIC M.21 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 22: Scrapping The Machine

    (EN, UNI) available. N.B. With reference to the “MACHINE DIRECTIVE 2006/42/CE” the declaration given below is to be understood as: “declaration of incorporation” in accordance with art 4.2 par. 1 and Attachment II.B. AIRMATIC M.22 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 23 Manufacturer. The technical documentation is lodged at OLI SpA, Via Canalazzo, 35 – 41036 Medolla (MO) Italy. Giorgio Gavioli Medolla 07/05/2012 (Legal Representative) AIRMATIC M.23 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 24 SPARE PARTS Intertek II 3 D CLASS II DIV.2 Intertek CODE: OLMVEUS01 | REV:5 | DATE:03/2016 AIRMATIC airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 25 18 Junction box cover 44 Split cover band 19 Junction box cover washer 45 Gasket for split cover clamp 20 Junction box cover screw 46 Anti-rotation plate 21 Junction box 47 V-RING 22 Mass retaining Seeger AIRMATIC R.25 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 26 Manual. - Never grease the bearing before the 2) Bearing noise period indicated in the Manual. - Lubricated again and possibly replace the bearing. - Use only the lubricant indicated on the Manual. AIRMATIC R.26 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 27 DRAWINGS AND CHART Intertek II 3 D CLASS II DIV.2 Intertek AIRMATIC airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 28 -SPARE PARTS II 3 D CLASS II DIV.2 Intertek TAB. 28 TAB. 28 AIRMATIC TAB.28 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 29 -SPARE PARTS II 3 D CLASS II DIV.2 Intertek TAB. 29 TAB. 29 AIRMATIC TAB.29 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 30 -SPARE PARTS II 3 D CLASS II DIV.2 Intertek TAB. 30 TAB. 30 AIRMATIC TAB.30 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 31 -SPARE PARTS II 3 D CLASS II DIV.2 Intertek TAB. 31 TAB. 31 AIRMATIC TAB.31 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 32 -SPARE PARTS II 3 D CLASS II DIV.2 Intertek TAB. 32 TAB. 32 AIRMATIC TAB.32 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 33 -SPARE PARTS II 3 D CLASS II DIV.2 Intertek TAB. 33 TAB. 33 AIRMATIC TAB.33 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 34 -DRAWINGS II 3 D CLASS II DIV.2 Intertek TAB. 34 TAB. 34 FIG. A FIG. B ØG AIRMATIC TAB.34 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 35 -DRAWINGS II 3 D CLASS II DIV.2 Intertek TAB. 35 TAB. 35 FIG. C FIG. D AIRMATIC TAB.35 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 36 -DRAWINGS II 3 D CLASS II DIV.2 Intertek TAB. 36 TAB. 36 FIG. E FIG. F AIRMATIC TAB.36 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 37 -DRAWINGS II 3 D CLASS II DIV.2 Intertek TAB. 37 TAB. 37 FIG. G ØG ØG ØG FIG. I AIRMATIC TAB.37 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 38 2 POLI II 3 D 3000 rpm 50 Hz CLASS II DIV.2 3600 rpm 60 Hz Intertek TAB. 38 TAB. 38 AIRMATIC TAB.38 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 39 2 POLI II 3 D CLASS II DIV.2 3000 rpm 50 Hz 3600 rpm 60 Hz Intertek TAB. 39 TAB. 39 AIRMATIC TAB.39 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 40 2 POLI II 3 D 3000 rpm 50 Hz CLASS II DIV.2 3600 rpm 60 Hz Intertek TAB. 40 TAB. 40 AIRMATIC TAB.40 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 41 2 POLI 1Ph II 3 D CLASS II DIV.2 3000 rpm 50 Hz 3600 rpm 60 Hz Intertek TAB. 41 TAB. 41 AIRMATIC TAB.41 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 42 2 POLI 1Ph II 3 D 3000 rpm 50 Hz CLASS II DIV.2 3600 rpm 60 Hz Intertek TAB. 42 TAB. 42 AIRMATIC TAB.42 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 43 4 POLI II 3 D 1500 rpm 50 Hz CLASS II DIV.2 1800 rpm 60 Hz Intertek TAB. 43 TAB. 43 TAB. 43 AIRMATIC TAB.43 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 44 4 POLI II 3 D 1500 rpm 50 Hz CLASS II DIV.2 1800 rpm 60 Hz Intertek TAB. 44 TAB. 44 TAB. 44 AIRMATIC TAB.44 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 45 4 POLI II 3 D 1500 rpm 50 Hz CLASS II DIV.2 1800 rpm 60 Hz Intertek TAB. 45 TAB. 45 TAB. 45 AIRMATIC TAB.45 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 46 6 POLI II 3 D 1000 rpm 50 Hz CLASS II DIV.2 1200 rpm 60 Hz Intertek TAB. 46 TAB. 46 AIRMATIC TAB.46 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 47 6 POLI II 3 D 1000 rpm 50 Hz CLASS II DIV.2 1200 rpm 60 Hz Intertek TAB. 47 TAB. 47 AIRMATIC TAB.47 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 48 6 POLI II 3 D 1000 rpm 50 Hz CLASS II DIV.2 1200 rpm 60 Hz Intertek TAB. 48 TAB. 48 AIRMATIC TAB.48 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 49 8 POLI II 3 D CLASS II DIV.2 750 rpm 50 Hz 900 rpm 60 Hz Intertek TAB. 49 TAB. 49 AIRMATIC TAB.49 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 50 8 POLI II 3 D 750 rpm 50 Hz CLASS II DIV.2 900 rpm 60 Hz Intertek TAB. 50 TAB. 50 AIRMATIC TAB.50 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 51 8 POLI II 3 D CLASS II DIV.2 750 rpm 50 Hz 900 rpm 60 Hz Intertek TAB. 51 TAB. 51 AIRMATIC TAB.51 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 52 10 POLI II 3 D 600 rpm 50 Hz CLASS II DIV.2 720 rpm 60 Hz Intertek TAB. 52 TAB. 52 AIRMATIC TAB.52 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 53 MICRO MVE II 3 D 3000 rpm 50 Hz CLASS II DIV.2 3600 rpm 60 Hz Intertek TAB. 53 TAB. 53 AIRMATIC TAB.53 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 54 MICRO MVE 1Ph II 3 D 3000 rpm 230 V 50 Hz CLASS II DIV.2 TAB. 54 TAB. 54 3600 rpm 115 V 60 Hz Intertek AIRMATIC TAB.54 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 55 MVE SIZE 20-50 (50 Hz) MVE SIZE 20-50 (60 Hz) MVE SIZE 20-50 (60 Hz) MVE SIZE 60-110 (50-60 Hz) MVE SIZE 60-90 (60 Hz) Fc. 100% 100% 100% Fc. 80% Fc. 50% AIRMATIC TAB.55 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 56 -MASS ADJUSTING II 3 D CLASS II DIV.2 Intertek TAB. 56 AIRMATIC TAB.56 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 57 -MASS ADJUSTING II 3 D CLASS II DIV.2 Intertek TAB. 57 AIRMATIC TAB.57 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 58 FLANGE -FRAME COVER - FRAME COVER - FLANGE FLANGE -FRAME Ft -Lb Ft - Lb Ft -Lb Ft -Lb Ft -Lb 18.4 18.4 18.4 38.4 Size 10 / MICRO MVE MASS Ft -Lb AIRMATIC TAB.58 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 59 -HANDLING II 3 D CLASS II DIV.2 Intertek TAB. 59 TAB. 59 ≥ 45° ≥ 45° ≥ 45° AIRMATIC TAB.59 airmatic.com | 215.333.5600 | infocenter@airmatic.com...
  • Page 60 -HANDLING II 3 D CLASS II DIV.2 Intertek TAB. 60 TAB. 60 CODE: OLMVEUS01 | REV:5 | DATE:03/2016 PN:10-10108 AIRMATIC TAB.50 airmatic.com | 215.333.5600 | infocenter@airmatic.com...

Table of Contents