  • Page 1 FCMF8-R INTELLIGENT TEMPERATURE, HUMIDITY AND CO SENSOR Mounting and operating instructions...
  • Page 2: Table Of Contents

    ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS MOUNTING INSTRUCTIONS IN STEPS OPERATING INSTRUCTIONS VERIFICATION OF INSTALLATION TRANSPORT AND STORAGE WARRANTY AND RESTRICTIONS MAINTENANCE MIW-FCMF8-R-EN-001 - 24 / 08 / 2020 2 - 9 www.sentera.eu...
  • Page 3: Safety And Precautions

    In case there are any questions that are not answered, please contact your technical support or consult a professional. MIW-FCMF8-R-EN-001 - 24 / 08 / 2020 3 - 9 www.sentera.eu...
  • Page 4: Product Description

    FCMF8-R INTELLIGENT TEMPERATURE, HUMIDITY AND CO SENSOR PRODUCT DESCRIPTION The FCMF8-R are intelligent multifunctional sensors featuring adjustable temperature, relative humidity and CO ranges. Their algorithm controls a single analogue / modulating output based on the measured T, rH and CO values, which can be used to directly control an EC fan or an actuator powered damper.
  • Page 5: Operational Diagrams

    Minimum Maximum Maximum range alert alert range T [°C] / rH [%] / CO [ppm]* LED indications - T (default), rH or CO MIW-FCMF8-R-EN-001 - 24 / 08 / 2020 5 - 9 www.sentera.eu back to the table of contents...
  • Page 6: Wiring And Connections

    Mount the internal enclosure into the wall using appropriate connecting elements (not included in the set). Mind the correct position and mounting dimensions shown in Fig. 2 and Fig. 3. MIW-FCMF8-R-EN-001 - 24 / 08 / 2020 6 - 9 www.sentera.eu...
  • Page 7 Customise the factory settings to the desired ones via the 3SModbus software or the Sensistant configurator. For the default factory settings, see the Modbus register map. MIW-FCMF8-R-EN-001 - 24 / 08 / 2020 7 - 9 www.sentera.eu back to the table of contents...
  • Page 8: Operating Instructions

    When the red LED is on, the measured value (temperature, relative humidity or ) is below the minimum measurement range value or above the maximum value. Blinking red LED indicates loss of communication with a sensor (Fig. 6 - 3). MIW-FCMF8-R-EN-001 - 24 / 08 / 2020 8 - 9 www.sentera.eu...
  • Page 9: Verification Of Installation

    In case of heavy pollution, clean with a non-aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. MIW-FCMF8-R-EN-001 - 24 / 08 / 2020 9 - 9 www.sentera.eu...