AIR CONDITIONER
Owner's Manual
Original Instructions
Local air conditioner
Invest Living PAC-09
Thank you for choosing our product.
Please read this Owner's Manual carefully before operation and
retain it for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PAC-09 and is the answer not in the manual?

Questions and answers

Summary of Contents for Invest Living PAC-09

  • Page 1 AIR CONDITIONER Owner's Manual Original Instructions Local air conditioner Invest Living PAC-09 Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference.
  • Page 2: Table Of Contents

    Content Operation Notices The Refrigerant ......................1 Safety Warning ......................2 Operation Environment ....................3 Part's Name ......................4 Operation Guide Operation Introduction for Control Panel ..............5 Buttons on Remote Controller .................7 Introduction for Icons on Display Screen ..............7 Introduction for Buttons on Remote Controller ............8 Function Introduction for Combination Buttons ............10 Operation Guide ....................
  • Page 3: Explanation Of Symbols

    Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 4: The Refrigerant

    Appliance filled with flammable gas R290. Before install and use the appliance, read the owner’s manual first. Before install the appliance, read the installation manual first. Before repair the appliance, read the service manual first. The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
  • Page 5: Safety Warning

    Safety Warning 7KLV DSSOLDQFH FDQ EH XVHG E\ FKLOGUHQ DJHG IURP  \HDUV DQG DERYH DQG SHUVRQV ZLWK UHGXFHG SK\VLFDO VHQVRU\ RU PHQWDO FDSDELOLWLHV RU ODFN RI H[SHULHQFH DQG NQRZOHGJH LI WKH\ KDYH EHHQ JLYHQ VXSHUYLVLRQ RU LQVWUXFWLRQ FRQFHUQLQJ XVH RI WKH DSSOLDQFH LQ D VDIH ZD\ DQG XQGHUVWDQG WKH KD]DUGV LQYROYHG &KLOGUHQ VKDOO QRW SOD\ ZLWK WKH DSSOLDQFH &OHDQLQJ DQG XVHU PDLQWHQDQFH VKDOO QRW EH PDGH E\ FKLOGUHQ...
  • Page 6: Operation Environment

    Safety Warning 'R QRW XVH DQ H[WHQVLRQ FRUG 'R QRW WKURXJK VXQGULHV LQWR WKH DLU GXFW ,I WKHUH DUH VXQGULHs get LQWR WKH DLU GXFW SOHDVH FRQWDFW WKH SURIHVVLRQDOV WR GHDO ZLWK LW Operation Environment 7KH DLU FRQGLWLRQHU PXVW EH RSHUDWHG ZLWKLQ WKH WHPSHUDWXUH range: 16°C ~ 35°C.
  • Page 7: Part's Name

    Part's Name Controller panel Swing louver Guide louver Castor Filter Joint Heat discharge pipe Joint B Joint C Plug of power cord Wire-fixing hook Remote controller NOTICE: Heat discharge pipe and other installation accessories can't be discarded.
  • Page 8: Operation Introduction For Control Panel

    Operation Introduction for Control Panel Name of control panel Dual-8 nixie tube Cool mode indicator + / - button Dry mode indicator Fan speed indicator Fan mode indicator Timer button Mode button SZLQJ button ON/OFF button Fan button Operation of control panel Note: After putting through the power, the air conditioner will give out a sound.
  • Page 9 Operation Introduction for Control Panel Mode button Press this button and the mode will circulate according to below se uence &22/ ' < FAN 8QGHU WKLV PRGH FRROLQJ PRGH LQGLFDWRU LV EULJKW 'XDO QL[ie tube displays set temperature. Temperature setting range is 16°C~30°C. 8QGHU WKLV PRGH GU\LQJ PRGH LQGLFDWRU LV EULJKW 'XDO QL[LH tube won’t display.
  • Page 10: Buttons On Remote Controller

    Buttons on Remote Controller Note: 7KLV UHPRWH FRQWUROOHU LV WKH XQLYHUVDO UHPRWH FRQWUROOHU 6RPH IXQFWLRQ LV QRW DYDLO DEOH IRU WKLV XQLW 212)) EXWWRQ 02'( EXWWRQ  EXWWRQ )$1 EXWWRQ 6:,1* EXWWRQ 6/((3 EXWWRQ 7,0(5 EXWWRQ Introduction for icons on display screen 7LPHU RQ 7LPHU RII 6HQGLQJ VLJQDO...
  • Page 11: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: :KHQ SRZHU LV FRQQHFWHG VWDQG E\ FRQGLWLRQ  \RX FDQ RSHUDWH WKH DLU FRQGLWLRQHU WKURXJK WKH UHPRWH FRQWUROOHU :KHQ XQLW LV RQ HDFK WLPH \RX SUHVV WKH EXWWRQ RQ UHPRWH FRQWUROOHU WKH VHQGLQJ VLJQDO LFRQ RQ WKH GLVSOD\ RI UHPRWH FRQWUROOHU ZLOO EOLQN RQFH ,I WKH DLU FRQ GLWLRQHU JLYHV RXW D EHHS VRXQG LW PHDQV WKH VLJQDO KDV EHHQ VHQW :KHQ XQLW LV RII VHW WHPSHUDWXUH ZLOO EH GLVSOD\HG RQ WKH UHPRWH FRQWUROOHU ,I WKH...
  • Page 12 Introduction for buttons on remote controller )$1 EXWWRQ 3UHVVLQJ WKLV EXWWRQ FDQ VHOHFW IDQ VSHHG FLUFXODUO\ DV $872 63(('  63(('   63(('   63(('  XQDYDLODEOH LQ WKLV DLU FRQGLWLRQHU 6SHHG  LV WKH VDPH ZLWK VSHHG   $872 63(('  HTXDOV WR ORZ IDQ VSHHG 63(('  HTXDOV WR PHGLXP IDQ VSHHG ...
  • Page 13: Function Introduction For Combination Buttons

    Introduction for Buttons on Remote Controller Note: Range of time setting is: 0.5~24h The interval between two motions can't exceed 5s, otherwise the remote con- troller will exit setting status. Function introduction for combination buttons Child lock function Press “+” and “-” buttons simultaneously can turn on or turn off child lock function. When child lock function is started up, LOCK indicator on remote controller is ON.
  • Page 14: Operation Guide

    Operation Guide After putting through the power, press "ON/OFF" button on remote controller to turn on the air conditioner. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN, HEAT. Press "+" or "-" button to set your required temperature. (Temperature can’t be adjusted under auto mode).
  • Page 15: Clean And Maintenance

    Clean and Maintenance WARNING Before cleaning the air conditioner, please turn off the unit and disconnect power. Otherwise, it may cause electric shock. Do not wash air conditioner with water. Otherwise, it may cause electric shock. Do not use volatile liquid (such as thinner or gas) to clean the air conditioner. Otherwise, it may damage the appearance of air conditioner.
  • Page 16 Clean and Maintenance Clean KHDW GLVFKDUJH pipe Remove the KHDW GLVFKDUJH pipe from air conditioner, clean and dry it , and then UHLQVWDOO LW )RU WKH PHWKRG RI LQVWDOODWLRQ DQG UHPRYDO  SOHDVH UHIHU WR WKH instruction for "Installation and disassembly of heat discharge pipe"). Checking before use-season 1.
  • Page 17: Malfunction Malfunction Analysis

    Malfunction $nalysis Please check below items before asking for maintenance. If the malfunction still FDQ¶W EH HOLPLQDWHG SOHDVH FRQWDFW ORFDO GHDOHU RU TXDOL¿HG SURIHVVLRQDOV Phenomenon Troubleshooting Solution 3RZHU IDLOXUH" :DLW DIWHU SRZHU UHFRYHU\ ,V SOXJ ORRVH" 5HLQVHUW WKH SOXJ :KHWKHU WKH DLU VZLWFK LV WULS $VN SURIHVVLRQDO SHUVRQ WR Air conditioner SHG RII RU IXVH LV EXUQW"...
  • Page 18 Malfunction Analysis Phenomenon Troubleshooting Solution :KHWKHU DLU RXWOHW RU DLU LQOHW LV (OLPLQDWH WKH REVWDFOHV blocked? 8QGHU KHDWLQJ PRGH ZKHWKHU 7KH XQLW ZLOO VWRS EORZLQJ indoor temperature ireaches fan after reaching set set temperature? temperature. ,Q RUGHU WR SUHYHQW FROG DLr 1R DLU EORZHG :KHWKHU KHDWLQJ PRGH is sta- DLU FRQGLWLRQHU ZLOO GHOD\ IRU D...
  • Page 19: Malfunction Code

    Malfunction analysis Malfunction code ERROR Troubleshooting CODE Please contact qualified professionals for service. Please contact qualified professionals for service. Please contact qualified professionals for service. Please contact qualified professionals for service. 1.Check if the unit is under high-temperature and high-humidity environment; if ambient temperature is too high, power off the unit and then energize it for operation after the ambient temperature drops to 35 below.
  • Page 20: Installation Precaution

    Installation Precaution WARNING 2EVHUYH DOO JRYHUQLQJ FRGHV DQG RUGLQDQFHV 'R QRW XVH GDPDJHG RU QRQVWDQGDUG SRZHU FRUG %H FDXWLRQ GXULQJ LQVWDOODWLRQ DQG PDLQWHQDQFH 3URKLELW LQFRUUHFW RSHUDWLRQ WR SUHYHQW HOHFWULF VKRFN FDVXDOW\ DQG RWKHU DFFLGHQWV Selection of installation location Basic requirement ,QVWDOOLQJ WKH XQLW LQ WKH IROORZLQJ SODFHV PD\ FDXVH PDOIXQFWLRQ ,I LW LV XQDYRLGDEOH SOHDVH FRQVXOW WKH ORFDO GHDOHU REMHFWV VSUHDG LQ WKH DLU...
  • Page 21: Requirements For Electric Connection

    Installation Precaution Requirements for electric connection WARNING: Safety precaution 1. Must follow the electric safety regulations when installing the unit. 2. According to the local safety regulations, use qualified power supply circuit. 3. For appliances with type Y attachment,the instructions shall contain the substance of the following.If the supply cord is damaged,it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Page 22: Preparation Before Installation

    Preparation before Installation Note: check if the accessories are available before installation. Accessory list joint A joint B joint C joint D joint E Plastic Cover pipe clip pipe hoop screw wire hook rubber plug heat discharge pipe battery drainage pipe remote controller (AAA 1.5V) user's manual...
  • Page 23: Install Wire Hook

    Install Wire Hook Assemble the wire hook at the back of the unit with screws (the direction of wire hook is as shown in following fig). direction of wire hook is upward wire hook screw direction of wire hook is downward Wind the power cord around the wire hook.
  • Page 24: Removing Collected Water

    Removing Collected Water There are 2 ways to remove collected water: Use the continuous drainage option from the bottom hole Note: When using the continuous drainage option from the bottom hole, drainage pipe before using, otherwise poor drainage will affect normal operation of the unit.
  • Page 25 Removing Collected Water 'UDLQDJH ZD\ DV IROORZV 1. In Cool or Dry mode operating, the condensation water will be drained to the chassis. 2. When the chassis is full with water, the buzzer will give out 8 sounds and "H8" is displayed to remind user to discharge water,the unit will turned off about 2min latter, and all buttons are invalid.
  • Page 26 Removing Collected Water Use the continuous drainage option from the middle hole Note: Water can be automatically emptied into a floor drain by attaching 14mm inner diameter hose (not included). Remove the continuous drain cap 1 by turning it counter clockwise then remove the rubber stopper 2 from the spout.
  • Page 27: Installation And Disassembly Of Heat Discharge Pipe

    Installation and Disassembly of Heat Discharge Pipe 1. Installation of the heat discharge pipe in sliding window 1. Rotate joint A and joint B clockwise into the two ends of heat discharge pipe. clockwise joint B clockwise heat discharge pipe joint A 2.
  • Page 28 Installation and Disassembly of Heat Discharge Pipe 2. Installation of the heat discharge pipe in immovable window: 1. Rotate joint A and joint B clockwise into the two ends of heat discharge pipe. clockwise joint B clockwise heat discharge pipe joint A 2.
  • Page 29 Installation and Disassembly of Heat Discharge Pipe 2. Installation of the heat discharge pipe in immovable window 4. Insert joint A of heat discharge pipe (the side with "TOP" is upwards) into the groove until you hear a sound. clasp the side with "TOP"...
  • Page 30 Installation and Disassembly of Heat Discharge Pipe Note of Installingheat discharge pipe The discharge pipe is suggested to be installed according to below figure by the manufacturer. under 51 inchs correct about 24 inchs User can adjust the installation method of the discharge pipe basing on the requirement, while the similar installation methods as below which will lead to unsmoothly air-out are not allowed.
  • Page 31 Installation and Disassembly of Heat Discharge Pipe Disassemble heat discharge pipe 1. Disassembly of the heat discharge pipe in sliding window: 1. Remove joint A: 2. Remove joint B: Press the clasp and lift joint A upwards to remove joint B from joint C. remove it.
  • Page 32 Installation and Disassembly of Heat Discharge Pipe 2. Remove the heat discharge pipe from the Joint D. Anti-clockwise 3. When heat discharge pipe is removed, Install the plastic cover into Joint D in case of the insect into the house . Clockwise Plastic Cover...
  • Page 33: Operation Test

    Operation Test 3XW WKURXJK WKH SRZHU VXSSO\ DQG WKHQ SUHVV 212)) EXWWRQ RQ UHPRWH FRQWUR OOHU WR VWDUW WKH XQLW 3UHVV PRGH EXWWRQ WR VHOHFW DXWR FRROLQJ GU\LQJ IDQ RU KHDWLQJ IXQFWLRQ DQG WKHQ FKHFN LI WKH XQLW RSHUDWHV QRUPDOO\ ,I DPELHQW WHPSHUDWXUH LV EHORZ ƒ& WKH XQLW FDQ W RSHUDWH LQ FRROLQJ PRGH Electric Schematic Diagram 7KH (OHFWULF VFKHPDWLF GLDJUDP DUH VXEjHFW WR FKDQJH ZLWKRXW QRWLFH 3OHDVH...
  • Page 34: Specialist's Manual

    Specialist’s Manual Aptitude requirement for maintenance man(repairs should be done only be specialists). a. All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. b.
  • Page 35 Specialist’s Manual Refrigeration equipment Checking Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance.
  • Page 36: Leak Detection Methods

    Specialist’s Manual Ensure that the apparatus is mounted securely. Ensure that seals or sealing materials have not degraded to the point that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications. NOTE : The use of silicon sealant can inhibit the effectiveness of some types of leak detection equipment.
  • Page 37: Charging Procedures

    Specialist’s Manual The refrigerant charge shall be recovered into the correct recovery cylinders. For appliances containing flammable refrigerants, the system shall be “flushed” with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant systems. For appliances containing flammable refrigerants, flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum.
  • Page 38 Specialist’s Manual f) Make sure that cylinder is situated on the scales before recovery takes place. g) Start the recovery machine and operate in accordance with manufacturer's instructions. h) Do not overfill cylinders. (No more than 80 % volume liquid charge). i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
  • Page 39 In such cases, Invest Living Scandinavia AB is responsible for costs that may arise in connection with the return and delivery of replacement products.
  • Page 40 Invest Living Scandinavia AB Add: Gyllings väg 9 Tel: +46 491 403000 E-mail: info@investliving.se www.investliving.se...