Page 1
AIR CONDITIONER Owner's Manual Original Instructions Local air conditioner Invest Living PAC-09 Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference.
Content Operation Notices The Refrigerant ......................1 Safety Warning ......................2 Operation Environment ....................3 Part's Name ......................4 Operation Guide Operation Introduction for Control Panel ..............5 Buttons on Remote Controller .................7 Introduction for Icons on Display Screen ..............7 Introduction for Buttons on Remote Controller ............8 Function Introduction for Combination Buttons ............10 Operation Guide ....................
Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
Appliance filled with flammable gas R290. Before install and use the appliance, read the owner’s manual first. Before install the appliance, read the installation manual first. Before repair the appliance, read the service manual first. The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
Part's Name Controller panel Swing louver Guide louver Castor Filter Joint Heat discharge pipe Joint B Joint C Plug of power cord Wire-fixing hook Remote controller NOTICE: Heat discharge pipe and other installation accessories can't be discarded.
Operation Introduction for Control Panel Name of control panel Dual-8 nixie tube Cool mode indicator + / - button Dry mode indicator Fan speed indicator Fan mode indicator Timer button Mode button SZLQJ button ON/OFF button Fan button Operation of control panel Note: After putting through the power, the air conditioner will give out a sound.
Page 9
Operation Introduction for Control Panel Mode button Press this button and the mode will circulate according to below se uence &22/ ' < FAN 8QGHU WKLV PRGH FRROLQJ PRGH LQGLFDWRU LV EULJKW 'XDO QL[ie tube displays set temperature. Temperature setting range is 16°C~30°C. 8QGHU WKLV PRGH GU\LQJ PRGH LQGLFDWRU LV EULJKW 'XDO QL[LH tube won’t display.
Introduction for Buttons on Remote Controller Note: Range of time setting is: 0.5~24h The interval between two motions can't exceed 5s, otherwise the remote con- troller will exit setting status. Function introduction for combination buttons Child lock function Press “+” and “-” buttons simultaneously can turn on or turn off child lock function. When child lock function is started up, LOCK indicator on remote controller is ON.
Operation Guide After putting through the power, press "ON/OFF" button on remote controller to turn on the air conditioner. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN, HEAT. Press "+" or "-" button to set your required temperature. (Temperature can’t be adjusted under auto mode).
Clean and Maintenance WARNING Before cleaning the air conditioner, please turn off the unit and disconnect power. Otherwise, it may cause electric shock. Do not wash air conditioner with water. Otherwise, it may cause electric shock. Do not use volatile liquid (such as thinner or gas) to clean the air conditioner. Otherwise, it may damage the appearance of air conditioner.
Page 16
Clean and Maintenance Clean KHDW GLVFKDUJH pipe Remove the KHDW GLVFKDUJH pipe from air conditioner, clean and dry it , and then UHLQVWDOO LW )RU WKH PHWKRG RI LQVWDOODWLRQ DQG UHPRYDO SOHDVH UHIHU WR WKH instruction for "Installation and disassembly of heat discharge pipe"). Checking before use-season 1.
Malfunction analysis Malfunction code ERROR Troubleshooting CODE Please contact qualified professionals for service. Please contact qualified professionals for service. Please contact qualified professionals for service. Please contact qualified professionals for service. 1.Check if the unit is under high-temperature and high-humidity environment; if ambient temperature is too high, power off the unit and then energize it for operation after the ambient temperature drops to 35 below.
Installation Precaution Requirements for electric connection WARNING: Safety precaution 1. Must follow the electric safety regulations when installing the unit. 2. According to the local safety regulations, use qualified power supply circuit. 3. For appliances with type Y attachment,the instructions shall contain the substance of the following.If the supply cord is damaged,it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Preparation before Installation Note: check if the accessories are available before installation. Accessory list joint A joint B joint C joint D joint E Plastic Cover pipe clip pipe hoop screw wire hook rubber plug heat discharge pipe battery drainage pipe remote controller (AAA 1.5V) user's manual...
Install Wire Hook Assemble the wire hook at the back of the unit with screws (the direction of wire hook is as shown in following fig). direction of wire hook is upward wire hook screw direction of wire hook is downward Wind the power cord around the wire hook.
Removing Collected Water There are 2 ways to remove collected water: Use the continuous drainage option from the bottom hole Note: When using the continuous drainage option from the bottom hole, drainage pipe before using, otherwise poor drainage will affect normal operation of the unit.
Page 25
Removing Collected Water 'UDLQDJH ZD\ DV IROORZV 1. In Cool or Dry mode operating, the condensation water will be drained to the chassis. 2. When the chassis is full with water, the buzzer will give out 8 sounds and "H8" is displayed to remind user to discharge water,the unit will turned off about 2min latter, and all buttons are invalid.
Page 26
Removing Collected Water Use the continuous drainage option from the middle hole Note: Water can be automatically emptied into a floor drain by attaching 14mm inner diameter hose (not included). Remove the continuous drain cap 1 by turning it counter clockwise then remove the rubber stopper 2 from the spout.
Installation and Disassembly of Heat Discharge Pipe 1. Installation of the heat discharge pipe in sliding window 1. Rotate joint A and joint B clockwise into the two ends of heat discharge pipe. clockwise joint B clockwise heat discharge pipe joint A 2.
Page 28
Installation and Disassembly of Heat Discharge Pipe 2. Installation of the heat discharge pipe in immovable window: 1. Rotate joint A and joint B clockwise into the two ends of heat discharge pipe. clockwise joint B clockwise heat discharge pipe joint A 2.
Page 29
Installation and Disassembly of Heat Discharge Pipe 2. Installation of the heat discharge pipe in immovable window 4. Insert joint A of heat discharge pipe (the side with "TOP" is upwards) into the groove until you hear a sound. clasp the side with "TOP"...
Page 30
Installation and Disassembly of Heat Discharge Pipe Note of Installingheat discharge pipe The discharge pipe is suggested to be installed according to below figure by the manufacturer. under 51 inchs correct about 24 inchs User can adjust the installation method of the discharge pipe basing on the requirement, while the similar installation methods as below which will lead to unsmoothly air-out are not allowed.
Page 31
Installation and Disassembly of Heat Discharge Pipe Disassemble heat discharge pipe 1. Disassembly of the heat discharge pipe in sliding window: 1. Remove joint A: 2. Remove joint B: Press the clasp and lift joint A upwards to remove joint B from joint C. remove it.
Page 32
Installation and Disassembly of Heat Discharge Pipe 2. Remove the heat discharge pipe from the Joint D. Anti-clockwise 3. When heat discharge pipe is removed, Install the plastic cover into Joint D in case of the insect into the house . Clockwise Plastic Cover...
Specialist’s Manual Aptitude requirement for maintenance man(repairs should be done only be specialists). a. All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. b.
Page 35
Specialist’s Manual Refrigeration equipment Checking Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance.
Specialist’s Manual Ensure that the apparatus is mounted securely. Ensure that seals or sealing materials have not degraded to the point that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications. NOTE : The use of silicon sealant can inhibit the effectiveness of some types of leak detection equipment.
Specialist’s Manual The refrigerant charge shall be recovered into the correct recovery cylinders. For appliances containing flammable refrigerants, the system shall be “flushed” with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant systems. For appliances containing flammable refrigerants, flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum.
Page 38
Specialist’s Manual f) Make sure that cylinder is situated on the scales before recovery takes place. g) Start the recovery machine and operate in accordance with manufacturer's instructions. h) Do not overfill cylinders. (No more than 80 % volume liquid charge). i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
Page 39
In such cases, Invest Living Scandinavia AB is responsible for costs that may arise in connection with the return and delivery of replacement products.
Page 40
Invest Living Scandinavia AB Add: Gyllings väg 9 Tel: +46 491 403000 E-mail: info@investliving.se www.investliving.se...