Xylem Mini Fix Tank VF Installation, Operation And Maintenance Manual
Xylem Mini Fix Tank VF Installation, Operation And Maintenance Manual

Xylem Mini Fix Tank VF Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Quick Links

Mini Fix Tank VF
, Operations and Maintenance manual – April 2025
Installation
Complementary Documents:
• PABLRM15 Pump IOM
Original Instructions – English
Keep for future reference.
CAUTION: Read instructions before using this machine
MINI FIX TANK VF IOM
UKLIT0271

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mini Fix Tank VF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Xylem Mini Fix Tank VF

  • Page 1 MINI FIX TANK VF IOM UKLIT0271 Original Instructions – English Keep for future reference. CAUTION: Read instructions before using this machine Mini Fix Tank VF , Operations and Maintenance manual – April 2025 Installation Complementary Documents: • PABLRM15 Pump IOM...
  • Page 2: Table Of Contents

    4.6.2 Connections for Volt free contact and External On / Off or External Level control ........14 4.6.3 Removing the front cover..........................15 4.6.4 Terminals connections ............................ 15 4.6.5 Mini Fix Tank VF Controller Wiring Diagram ....................16 4.6.6 Supplying the Controller with Power ....................... 16 4.6.7 Line Protection ..............................16 4.6.8 RCD (Residual Current Device) ........................
  • Page 3 8.2 Materials in contact with the water ........................29 8.3 Performance / Pump Curves ..........................29 8.4 Dimensions of the Mini Fix Tank VF ........................30 8.5 Weight of the Mini Fix Tank VF Unit ........................31 8.6 Electrical specification ............................31 8.7 Sound output ................................. 31 9.
  • Page 4: Introduction & Safety

    Safety instruction where noncompliance could cause damage to the equipment. Safety instruction where PPE (Personal Protective Equipment) is required. Where shown indicates the location of a Protective Earth bonding point Where shown advises the user to consult the manual Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 5: Instruction For Safe Use

    You must comply with local regulations when disposing of the product or packaging. WARNING: If the Mini Fix Tank VF has been exposed to ionizing radiations, implement the necessary safety measures for the protection of people. When shipping the Pump set, inform the carrier and the recipient accordingly, so that appropriate safety measures can be put in place.
  • Page 6: Handling And Storage

    Protected from vibrations. • • At and ambient temperature between 4°C and +40°C • Do not place heavy loads on top of the unit. • Protect the unit from collisions. Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 7: Technical Description

    3.2 Data plate On the Mini Fix Tank VF, there will be two Name plates on the unit. One supplying information for the Pump installed inside the cabinet and the other is the Model data for the Mini Fix Tank VF Booster Set.
  • Page 8: Mini Fix Tank Pump Data Plate

    Part Number of the pump 3.3 Identification Code / Nomenclature Example: Mini Fix Tank VF Reference Description Mini Fix Tank Product range name Version with volt free output for fault Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 9: Names Of The Main Components

    EN – Original Instructions 3.4 Names of the Main Components For procurement of spare parts or exploded parts diagram, please contact the sales office. Mains water supply 15mm Overflow/Warning 22mm Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 10: Intended Use

    It is prohibited to use this unit to Pump flammable and/or explosive liquids. DANGER: Potentially explosive atmosphere hazard It is prohibited to start and run the unit in environments with potentially explosive atmospheres or with combustible dust. Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 11 Areas which exceeded the ambient temperature rated for the product. Areas that are exposed to the elements and direct sunlight. For information of installation environments • please see section 4 Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 12: Installation

    4.2 Installation Considerations When installing the Mini Fix Tank VF, make sure there is sufficient space above the unit to facilitate the removal of the cabinet lid and access to the Break Tank for maintenance. Additionally, it is advisable to provide adequate space on both the right and left sides of the unit to accommodate the pipework connections going into and out of the Mini Fix Tank VF.
  • Page 13: Installation - Floor Installation

    In addition to the installation recommendations stated for 4.3 Installation – Floor Installation • Check that the chosen Mini Fix Tank VF wall installation area is flat and can support the weight of the Mini Fix Tank VF. The weight of the product can be found in section 8.5.
  • Page 14: Overflow

    4.5.4 Outlet / Discharge connection Connect the Mini Fix Tank VF discharge connection located at the rear of the unit. The connection is 15mm Push fit. It is advised to fit an external isolation valve after the set for added ease of maintenance.
  • Page 15: Cable Entry Into The Cabinet

    External On / Off or External level control Yellow External On / Off or External level control For more information, please see the diagram in section 4.6.5 Mini Fix Tank VF Controller Wiring Diagram Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 16: Removing The

    Supply Neutral Neutral connection from the incoming power supply. Marked as “L2” on the controller Pump live Live connection to the Pump. Marked as “U” on the controller Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 17: Mini Fix Tank Vf Controller Wiring Diagram

    4.6.8 RCD (Residual Current Device) The Mini Fix Tank VF is not fitted with a residual current device. The user / installer will need to ensure that the power source to the Mini Fix Tank VF is fitted with an RCD.
  • Page 18: Earthing The Mini Fix Tank Vf

    The Mini Fix Tank VF must always be earthed. The installer / user should ensure that the power supply used for the Mini Fix Tank VF includes an earth from the main protective bonding conductors within the building or the supply is fitted with an earth spike.
  • Page 19: Use And Operation

    Button to navigate Down on the HMI / Decrease value / adjust the stop pressure Enter / On Button to accept / Toggle parameter Current / “Amps” button Button to view the current / adjust the current protection Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 20: Led Indicators On The Controller

    Alarm Led Solid Indicates the controller is in Alarm / Error condition 5.2.4 Status Screen To view system information on the Mini Fix Tank VF Controller while the unit is running, please see the below. Description Button combination Unit Range...
  • Page 21: Advanced Menu

    Allows the installer to set a minimum operating pressure pressure under which the device would determine threshold dry-running operation. This alarm is shown as A11 P0.0 to Px.x 0 bar Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 22: Counter / Alarm Logs

    Pump is switched off and not running. • Press to advance to the next counter in the sequence. To view the list of alarms displayed on the Mini Fix Tank VF, please see section 6.2 Mini Fix Tank VF Controller Alarms Relating to Display message Description...
  • Page 23: Art Function (Automatic Reset Test)

    5.6 Low Water / External On On the right side of the Mini Fix Tank VF controller, there is a set of terminals designed for use as either a float switch or an external on/off input. The controller's response can be customized based on the application within the advanced menu.
  • Page 24: Commissioning

    2. That there is no damage to the tank or components 3. Ensure the water tank is clean. 4. With the power supply off. Open the water supply to the Mini Fix Tank VF water tank and fill with water until the ball valve closes and stops further filling.
  • Page 25: Removing Trapped Air Before Starting Up

    When free of air, close the discharge valve, and the controller will detect the rise in pressure, stopping the Pump once the "P Stop" is achieved. Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 26: Troubleshooting

    Nitrogen or dry air The Pump runs but starts and There could be a problem with the Check the float and the tank. stops frequently level float in the in- take tank. Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 27: Mini Fix Tank Vf Controller Alarms

    Pump unit is delayed by 5 s • If parameter 2 = rc2, the Pump unit stops A05 – Steady Defective pressure sensor Contact Xylem or the Authorised distributor Pressure Sensor Faulty Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 28 (Px.x) - • Check to see if the float switch is free to move switch) previously set - during a period and has not become tangled. (txx) Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 29: Maintenance

    2. Reconnect the inlet and fill the tank with fresh clean water. 7.4 Spare parts Spare parts for the Mini Fix Tank VF are available to purchase from Lowara UK. Please contact the sales office for more information or visit the Lowara Spark website for Exploded parts diagrams.
  • Page 30: Technical Information

    8. Technical Information 8.1 Operating / Installation Environment The Mini Fix Tank VF has an IP rating of IP55 and should not be installed in an environment where the unit exposed to direct sunlight and/or near heat sources. IP protection Ambient temperature 4–40°C (39–122°F)
  • Page 31: Dimensions Of The Mini Fix Tank Vf

    EN – Original Instructions 8.4 Dimensions of the Mini Fix Tank VF Overflow/Warning 22mm Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 32: Weight Of The Mini Fix Tank Vf Unit

    Part Number Electrical Motor size Full Load Supply (kW) Current (amps) Mini Fix Tank VF PABLRM15 135A01002 230/1/50 0.37kW 2.5A 8.7 Sound output Noise Emissions Less than 70 dB (A). Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 33: Disposal

    Mini Fix Tank VF – Installation, Operation and Maintenance Manual...
  • Page 34 For more information on how Xylem can help you, go to www.xylem.com Xylem Water Solutions UK Ltd. Millwey Rise Industrial Estate...

Table of Contents