A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
• C r i t i c a l a n d e x p e d i t e d s e r v i c e s
• I n s t o c k / R e a d y - t o - s h i p
Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate, representative, or authorized distributor for any manufacturer listed herein.
$
375
.00
In Stock
Qty Available: 1
Used and in Excellent Condition
Open Web Page
https://www.artisantg.com/78539-2
• We b u y y o u r e x c e s s , u n d e r u t i l i z e d , a n d i d l e e q u i p me n t
• F u l l - s e r v i c e , i n d e p e n d e n t r e p a i r c e n t e r
Iec three phase ac motors (aluminum frame) (8 pages)
Summary of Contents for Baldor Reliance VM7010A
Page 1
Baldor VM7010A AC Motor In Stock Qty Available: 1 Used and in Excellent Condition Open Web Page https://www.artisantg.com/78539-2 A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
Page 3
Any trademarks used in this manual are the property of their respective owners. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 4
Table of Contents Section 1 General Information ................1−1 Overview .
Page 5
Section 1 General Information ii Table of Contents MN408 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
This manual describes general guidelines that apply to most of the motor products shipped by Baldor. If you have a question about a procedure or are uncertain about any detail, Do Not Proceed. Please contact your Baldor distributor for more information or clarification.
Page 7
Baldor distributor or an Authorized Baldor Service Center. Receiving Each Baldor Electric Motor is thoroughly tested at the factory and carefully packaged for shipment. When you receive your motor, there are several things you should do immediately.
Page 8
3. Measure and record the resistance of the winding insulation (dielectric withstand) every 30 days of storage. a. If motor insulation resistance decreases below the minimum resistance, contact your Baldor District office. b. Place new desiccant inside the vapor bag and re−seal by taping it closed.
Page 9
A decrease in resistance indicates moisture in the windings and necessitates electrical or mechanical drying before the motor can be placed into service. If resistance is low, contact your Baldor District office. 3. Regrease the bearings as instructed in Section 3 of this manual.
Page 10
II 3 G IP______ Marking of Sira__________________ Explosion Protection IECEx__________________ MFG. BY BALDOR ELECTRIC FORT SMITH, AR 72901 European Conformity Mark ATEX Equipment Group and Category (II3) Type of Atmosphere: G-Gas, D-Dust (G) Place of Manufacture Specific Conditions of Use: If the motor certificate number is followed by the symbol “X”, this indicates that the motor has specific...
Page 11
1−6 General Information MN408 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
The standard motor base is designed for horizontal or vertical mounting. Adjustable or sliding rails are designed for horizontal mounting only. Consult your Baldor distributor or authorized Baldor Service Center for further information.
Page 13
Frame Mounting Holes Some motors have standardized frames containing 6 or 8 mounting holes. 6 hole frames are not suitable for field reversal of mounting from F−1 to F−2, etc. Figure 2-2 indicates the proper mounting holes to use. Figure 2-2 6 & 8 Hole Motor Frame Mounting For short frame designations 182, 213, Top View Allows F-1 to F-2 Conversion on 8 hole...
Page 14
Doweling & Bolting After proper alignment is verified, dowel pins should be inserted through the motor feet into the foundation. This will maintain the correct motor position should motor removal be required. (BaldorSReliance motors are designed for doweling.) 1. Drill dowel holes in diagonally opposite motor feet in the locations provided. 2.
Page 15
Conduit Box For ease of making connections, an oversize conduit box is provided. Most conduit boxes can be rotated 360 in 90 increments. Auxiliary conduit boxes are provided on some motors for accessories such as space heaters, RTD’s etc. AC Power Motors with flying lead construction must be properly terminated and insulated.
Page 16
Note: Main power leads for CE Marked Motors may be marked U,V,W – for standard configurations, please consult connection diagrams. Caution: The space heaters are designed to operate at or below the maximum surface temperature stated on the nameplate. If the marked ambient and/or voltage are exceeded this maximum surface temperature can be exceeded and can damage the motor windings.
Figure 2-4 Typical Motor Performance VS Voltage Variations Maximum Full -Load Torque Current Full -Load Power Current Factor Efficiency Efficiency −5 −10 −15 Power Maximum Factor Torque −20 −15 −10 −5 Voltage Variations (%) Initial Lubrication BaldorSReliance motors are shipped from the factory with the bearings properly packed with grease and ready to operate.
Class I Division 1 / Zone 1 [Equipment Group I (mining) or II (surface), Equipment Protection Level (EPL) Gb, Mb ] Baldor offers a range of motors suitable for installation in a Division 1 or Zone 1 environment. These motors are known as explosion proof or flameproof.
Page 20
Flameproof motors, internationally referred to as Ex d use a protection concept similar to that used in Class I Division 1 motors, with minor differences in the flameproof joints and cable entry designs. Flameproof and explosion proof motors are both type tested. Representative motors are connected to a reference gas and ignited in laboratory conditions to verify that the flame is not transmitted outside the motor enclosure and to determine the maximum internal pressure encountered.
Page 21
Consult Baldor Electric Company for flameproof joint construction details. Use only BaldorSReliance supplied parts. Baldor does not recommend reclamation of parts. Since this protection method also relies on temperature being maintained, make sure that any rewinding uses the original electrical designs, including any thermal protection that may be present.
Maintenance & Troubleshooting WARNING: UL and EX Listed motors must only be serviced by UL or EX Approved Authorized Baldor Service Centers if these motors are to be returned to a hazardous and/or explosive atmosphere. General Inspection Inspect the motor at regular intervals, approximately every 500 hours of operation or every 3 months, whichever occurs first.
Page 23
Relubrication intervals are for ball bearings. For vertically mounted motors and roller bearings, divide the relubrication interval by 2. ** For motors operating at speeds greater than 3600 RPM, contact Baldor for relubrication recommendations. Table 3-3 Service Conditions Severity of Service...
Page 24
Relubrication Procedure Be sure that the grease you are adding to the motor is compatible with the grease already in the motor. Consult your Baldor distributor or an authorized service center if a grease other than the recommended type is to be used.
Page 25
Sample Relubrication Determination Assume - NEMA 286T (IEC 180), 1750 RPM motor driving an exhaust fan in an ambient temperature of 43 C and the atmosphere is moderately corrosive. 1. Table 3-2 list 9500 hours for standard conditions. 2. Table 3-3 classifies severity of service as “Severe”. 3.
Excessive humming High Voltage. Check input line connections. Eccentric air gap. Have motor serviced at local Baldor service center. Motor Over Heating Overload. Compare actual amps Locate and remove source of excessive friction in (measured) with nameplate rating.
Page 27
Suggested bearing and winding RTD setting guidelines for Non−Hazardous Locations ONLY Most large frame AC Baldor motors with a 1.15 service factor are designed to operate below a Class B (80C) temperature rise at rated load and are built with a Class H winding insulation system. Based on this low temperature rise, RTD (Resistance Temperature Detectors) settings for Class B rise should be used as a starting point.
Page 28
Baldor District Offices Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 29
World Headquarters P.O. Box 2400 Fort Smith, AR 72901−2400 (479) 646−4711 Fax (479) 648−5792 www.baldor.com 2009 Baldor Electric Company All rights reserved. Printed in USA MN408 8/12 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Need help?
Do you have a question about the Reliance VM7010A and is the answer not in the manual?
Questions and answers