visionLINE PERA-AU Installation And Owner's Manual

Freestanding

Advertisement

PERA - AU
freestanding
INSTALLATION AND OWNERS MANUAL
Version 1 2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PERA-AU and is the answer not in the manual?

Questions and answers

Summary of Contents for visionLINE PERA-AU

  • Page 1 PERA - AU freestanding INSTALLATION AND OWNERS MANUAL Version 1 2022...
  • Page 2: Unit Dimensions

    UNIT DIMENSIONS WOODFIRE COMPLIANCE LABEL This appliance has been TESTED TO AS/NZS4013 for Hardwood by ASFT Report 22021 Date tested: 7 April 2022 VisionLINE Pera Freestanding and Inbuilt OVERALL AVERAGE EFFICIENCY WHEN TESTED IN ACCORDANCE WITH AS/NZS 4012..61% AVERAGE PARTICULATE EMISSION FACTOR WHEN TESTED IN ACCORDANCE WITH AS/NZS 4013..1.0 G/KG...
  • Page 3 The VisionLINE Pera may require an insulating Floor Protector depending on the installation type. It is tested and complies with the minimum Floor Protector requirements of AS/NZS 2918:2018. See below for Hearth Please note: 300mm hearth specifications. projection min. when...
  • Page 4: Install Guide

    VisionLINE fireplaces. operating instructions. • Installation and/or use of any component part not approved by VisionLINE fireplaces. CAUTION • Operating appliance without fully assembling all components. Check building codes prior to installation.
  • Page 5 Manual bag and all of its contents are removed from inside/under the appliance ______________________________________ and given to the party responsible for use and operation. VisionLINE fireplaces recommends the following: • Photographing the installation and copying this checklist for your file.
  • Page 6: Minimum Height Of Flue System Exit

    VisionLINE fireplaces recommends using spigot. either VisionLINE Default flue kits or Please Note - Flue starter spigot removed from unit for VisionLINE AIR insulated flue kits. demonstration purposes only, removal of this spigot is not...
  • Page 7 (Towards the right - FIG 1) SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY The Visionline Pera is designed and tested as an RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE FIG 1 intermittent heating appliance and is not intended to be MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE.
  • Page 8: Combustion Air

    The central air duct must be led outdoors or into a well-ventilated room inside the building (cellar, utility room, etc.). VisionLINE fireplaces recommends the VisionLINE AIR insulated flue system to create a balanced flue ensuring adequate air supply balance. It is critical to have an air tight sealon the connection to the heater to outside air to ensure no loss of vacuum to the air intake which could result in starvation of air and poor performance.
  • Page 9: Troubleshooting

    Fig 10 Fig 11 Troubleshooting With proper installation, operation, and maintenance your wood appliance will provide years of trouble-free service. If Then turn the top brick down Push the top brick towards the back edge of the back you do experience a problem, this troubleshooting guide will assist you or a qualified service person in the diagnosis of brick a problem and the corrective action to be taken.
  • Page 10: Other Rights

    (5) environmental conditions, inadequate ventilation, VisionLINE warrants to the original owner of the VisionLINE appliance at the site of installation, and to any transferee negative pressure, or drafting caused by tightly sealed constructions, insufficient make-up air supply, or taking ownership of the appliance at the site of installation within two years following the date of original purchase, handling devices such as exhaust fans or forced air furnaces or other such causes;...

This manual is also suitable for:

Pera

Table of Contents