Download Print this page
Honeywell NOTIFIER DVC-RPU Manual
Honeywell NOTIFIER DVC-RPU Manual

Honeywell NOTIFIER DVC-RPU Manual

Remote paging unit for the dvc system

Advertisement

Quick Links

Remote Paging Unit for the DVC
System
DVC-RPU
Manual
Document 50107425-001
9/9/13
P/N 50107425-001:B1
B1
Rev:
ECN 13-201

Advertisement

loading
Need help?

Need help?

Do you have a question about the NOTIFIER DVC-RPU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Honeywell NOTIFIER DVC-RPU

  • Page 1 Remote Paging Unit for the DVC System DVC-RPU Manual Document 50107425-001 9/9/13 Rev: P/N 50107425-001:B1 ECN 13-201...
  • Page 2 Fire Alarm & Emergency Communication System Limitations While a life safety system may lower insurance rates, it is not a substitute for life and property insurance! (caused by escaping gas, improper storage of flammable materi- An automatic fire alarm system—typically made up of smoke als, etc.).
  • Page 3: Installation Precautions

    HARSH™, NIS™, Notifier Integrated Systems™, and NOTI•FIRE•NET™ are all trademarks; and Acclimate® Plus, FlashScan®, NION®, NOTIFIER®, ONYX®, ONYXWorks®, UniNet®, VeriFire®, and VIEW® are all registered trademarks of Honeywell International Inc. Echelon® is a registered trademark and LonWorks™ is a trademark of Echelon Corporation. ARCNET® is a registered trademark of Datapoint Corporation. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation.
  • Page 4: Software Downloads

    •Brief description of content you think should be improved or corrected •Your suggestion for how to correct/improve documentation Send email messages to: FireSystems.TechPubs@honeywell.com Please note this email address is for documentation feedback only. If you have any technical issues, please contact Technical Services.
  • Page 5: Table Of Contents

    Table of Contents Section 1: General Information....................6 1.1: Product Description ............................6 1.2: Standards and Other Documents........................6 1.3: Related Documentation ..........................7 1.4: Cautions and Warnings ..........................7 Section 2: Overview........................8 2.1: Description..............................8 2.1.1: Features..............................8 2.1.2: Options ..............................8 2.1.3: Specifications............................8 2.2: DVC-RPU Board Layout..........................9 2.2.1: Connections ............................9 2.2.2: Indicators ............................10 2.3: Options: Fiber Option Boards........................11...
  • Page 6: Section 1: General Information

    Section 1: General Information 1.1 Product Description The DVC-RPU is a Remote Paging Unit used with the DVC system for applications that require remote paging or remote control annunciation. Each DVC-RPU assumes one address on the digital audio loop of the DVC using wire media, or fiber media using optional fiber conversion modules. DVC programming allows the DVC-RPU to be configured to fulfill requirements for multiple pag- ing priorities such as emergency, fire, and non-emergency paging, and to use the 24 programmable DVC-KD buttons on the keypad for control and annunciation of points or software zones.
  • Page 7: Related Documentation

    Related Documentation General Information 1.3 Related Documentation The table below provides a list of documents referenced in this manual, as well as documents for other compatible devices. VeriFire Tools help file Included in VeriFire Tools DVC Digital Voice Command Manual 52411 DVC-KD Keypad Product Installation Document 52709...
  • Page 8: Section 2: Overview

    Section 2: Overview 2.1 Description The DVC-RPU consists of a control board and a DVC-KD keypad. A CMIC-RP microphone and well are ordered separately. The DVC-RPU may be mounted in a CAB-RP cabinet (with keyed entry) or a CAB-4 Series cabinet. A monitor module on the SLC of a fire alarm control panel is required when a tamper switch is used to indicate the DVC-RPU’s cabinet door has been opened.
  • Page 9: Dvc-Rpu Board Layout

    DVC-RPU Board Layout Overview Common, non-supervised. Recommended wiring: 14-18 AWG twisted-pair (max. 14 AWG). 2.2 DVC-RPU Board Layout 2.2.1 Connections Board connections for the DVC-RPU are illustrated and identified in Figure 2.1. No Connection Fiber Module Pin Connections J15 J16 No Connection No Connection TB3 - Digital...
  • Page 10: 2: Indicators

    Overview DVC-RPU Board Layout 2.2.2 Indicators LED indicator locations on the DVC-RPU are illustrated in Figure 2.2. Not Used Not Used LED 24 RXA LED 22 TXA LED 23 TXA LED 25 RXA Not Used LED 3 TRBL LED 12 MIC ACT LED 20 PWR LED 1 RESET LED 21 STATUS...
  • Page 11: Options: Fiber Option Boards

    Options: Fiber Option Boards Overview LED Name Color Description LED # Green Illuminated while data is received on Digital Audio Port (DAP) B. Illumination will flicker on wire versions, turning on when activity is detected and off when it is not. LED does not illuminate for fiber media.
  • Page 12 Overview Options: Fiber Option Boards Find the rated dB loss per foot within the cable manufacturer’s specifications. Determine the total attenuation between the two nodes due to the cable. Loss = (loss/ft.) x (length in feet) Establish the dB loss for each connector and splice. Sum all the losses. Total the attenuation factors obtained in steps 1 and 2.
  • Page 13 Options: Fiber Option Boards Overview DVC-RPU Manual P/N 50107425-001:B1 9/9/13...
  • Page 14: Section 3: Installation

    Section 3: Installation 3.1 Fiber Option Modules The DVC-RPU will require fiber option modules if it is part of a fiber DAL (Digital Audio Loop) segment. The standoffs between the DVC-RPU board and the keypad provide room to install the modules without removing the keypad.
  • Page 15: Dvc-Rpu Keypad (Dvc-Kd)

    DVC-RPU Keypad (DVC-KD) Installation 3.2 DVC-RPU Keypad (DVC-KD) 1. Screw the four 2-3/4” male/female 4-40 metal standoffs (included, p/n 42163) onto the DVC-RPU standoff studs on the back side of the DVC-KD. 2. Carefully attach the DVC-KD pin connector (included, p/n 08589) to the DVC- RPU board at J6.
  • Page 16: Cabinet Mounting

    Installation Cabinet Mounting 3.3 Cabinet Mounting The DVC-RPU and its local microphone and well, CMIC-RP, mount in the CAB-RP cabinet. It can also be mounted in a CA-1 chassis in a CAB-4 Series cabinet, using the CMIC-RP as its local microphone and well.
  • Page 17: 2: Cab-4 Series Cabinet

    Wiring Installation 3.3.2 CAB-4 Series Cabinet The DVC-RPU mounts in a CA-1 chassis for CAB-4 installations. This chassis occupies one row of a CAB-4 series enclosure. The left side accommodates the DVC-RPU, and the right side houses a CMIC-1, which consists of a MIC-1 microphone and well. Refer to the CMIC-1 document for the mounting instructions.
  • Page 18: 2: Digital Audio Ports A And B

    Installation Wiring 3.4.2 Digital Audio Ports A and B Wire Terminals Digital Audio Ports A and B (DAP A and DAP B) support a direct connection with digital audio loop devices that have wire DAP terminals. See “Digital Audio Ports A and B - TB2, TB3” on page 8 as well as the Wiring Guide, p/n 52916ADD, for cable types and associated distances between ports.
  • Page 19: 3: Push-To-Talk Indicator

    Wiring Installation Fiber Connections (Using Fiber Option Modules) When a fiber option module is used to convert the DVC-RPU’s wire digital audio port to a fiber port, the DVC-RPU will provide a direct connection to any fiber DAL device. Refer to “Options: Fiber Option Boards”...
  • Page 20: 5: Ul Power-Limited (Class 2) Wiring Requirements

    Installation Reading and Setting the DAL Address 3.4.5 UL Power-limited (Class 2) Wiring Requirements DVC-RPU circuit wiring is all power-limited (Class 2), and it may enter or exit the cabinet together. However, when the DVC-RPU is in a cabinet with another product that has non-power- limited wiring, all of the DVC-RPU’s circuitry must be separated from any non-power-limited cir- cuitry in the cabinet.
  • Page 21 Reading and Setting the DAL Address Installation DVC-RPU Manual P/N 50107425-001:B1 9/9/13...
  • Page 22: Section 4: Operation

    Section 4: Operation 4.1 Using the DVC-KD Keypad on the DVC-RPU The DVC-KD allows the DVC-RPU to accept and route live paging, with LED status indicators for paging and other functions. The DVC-KD contains push-button switches and indicators of two types: •...
  • Page 23: 2: 24 User-Programmable Buttons In The Two Right Columns

    Paging Operation Press this button to read or program the DVC-RPU’s DAL (Digital Audio Loop) address. Refer to “Reading and Setting the DAL Address” on page 20 for instructions. All-Call Level Buttons Press this button to initiate All Call paging at the level indicated on the label. The user creates the button labels, using terms that clarify the function, such as Remote Page, Fire Page, or General Page.
  • Page 24 Operation Paging Remove the microphone from its cradle. Press the DVC-KD button for the desired paging zone (for example, Level 1 ALL CALL). The green LED at the ALL CALL button will light steady. Press the push-to-talk button on the microphone. If there is a pre-announce tone, it will play at this time and the Pre-Announce LED will light as it plays.
  • Page 25 Paging Operation DVC-RPU Manual P/N 50107425-001:B1 9/9/13...
  • Page 26: Index

    Index Numerics TR-RP trim ring 16 24VDC Power 8 User-programmable Buttons 23 CAB-RP 8 CMIC-RP 8 VeriFire Tools 8 DAA2 18 DAX 18 Digital Audio Ports A and B 8 DS-DB 18 DS-RFM 12 DVC-KD 8 Indicators 22 Labels 15 Pre-defined Buttons 22 Slide-in labels 15 DVC-RPU...
  • Page 27: Manufacturer Warranties And Limitation Of Liability

    Manufacturer Warranties and Limitation of Liability Manufacturer Warranties. Subject to the limitations set forth herein, Manufacturer warrants that the Products manufactured by it in its Northford, Connecticut facility and sold by it to its authorized Distributors shall be free, under normal use and service, from defects in material and workmanship for a period of thirty six months (36) months from the date of manufacture (effective Jan.
  • Page 28 World Headquarters 12 Clintonville Road Northford, CT 06472-1610 USA 203-484-7161 fax 203-484-7118 www.notifier.com...