Bus Couplers - PX-TCP1
PX-TCP1 $347.00
P X -T C
P 1
L IN K /A
C T
PE
The PX-TCP1 Modbus TCP Server Bus
Coupler allows connection of up to 64
WD ERR
terminals per assembly, 255 terminals
total, in a Modbus TCP network. The
1
5
COM
PX-TCP1 communicates using high-level
2
6
Modbus commands and supports 512
bytes of input data and 512 bytes of
3
7
Error
output data.
4
8
8
24V 0V
The PX-TCP1 includes one RJ45 Ethernet
10/100 Base-T port for connection to a
Modbus client.
Configuration
Port
1
5
5
5
5
2
6
6
6
6
3
7
7
7
7
4
8
8
8
8
Ethernet
RJ45
Port
Us GNDs
DIN Rail
Locking
Up
Wheel
GNDp
Last Octet
of IP
Address
TM
.PE
DHCP
BootP
www.automationdirect.com
5
1
6
2
7
3
8
4
P X -T C P 1
Us
Up
I/O BUS RUN
I
I
I
I
I
I/O BUS ERR
/
/
/
/
/
/
O
O B
O
I/O Bus
contacts
Bus
Coupler
24V 0V
Power In
24VDC
+
Terminal
+
Power In
24 VAC/VDC
DIN Rail
Release
Tab
Terminal
Power In
0V
PE
PE
Terminal
Power In
PE (Earth
Ground)
PX-TCP1
PX-TCP1
Terminal
Power Bus
Contacts
PX-TCP1 I/O Bus Specifications
Supply Power for I/O Bus
Input Current from Power Supply
Recommended Fuse
I/O Bus Current Supply
Number of Bus Terminals
Supported
Number of Discrete Inputs/
Outputs
Number of Analog Inputs/
Outputs
Maximum Number of Data
Bytes*
* Total number of terminals cannot exceed 512 input bytes and 512 output bytes.
PX-TCP1 Terminal Power Bus Specifications
Supply Power for Terminal Bus
Maximum Current
Number of Power Contacts
PX-TCP1 Modbus Port Specifications
Configuration
Protocol
Data Transfer Rates
Maximum Cable Length
Connector Type
Recommended Cable
General Specifications
Operating Temperature
Storage Temperature
Relative Humidity
Environment Air
Mounting/Orientation
Restrictions
Vibration
Shock
Noise Immunity
Protection Class
Weight
Dimensions (WxHxD)
Agency Approvals*
* To obtain the most current agency approval information, see the Agency Approval Checklist
section on the specific part number's web page.
IMPORTANT!
For the latest prices, please check AutomationDirect.com.
24VDC (-15%/+20%)
70mA + (total I/O bus current) / 4
10A Max
1000mA Max
64 per assembly, 255 w/ I/O Bus Expansion (based on
power
budget)
1020 Inputs and 1020 Outputs with 255 terminals
128 total
512 Input Bytes and 512 Output Bytes
24 VAC/VDC
10A
3 (+24 VAC/VDC, 0V, PE)
DIP switches and PX-CFGSW software
Modbus TCP
10/100 Mbaud
100m between Coupler and switch
Ethernet, RJ45
Shielded, Twisted Pair, Cat5e
32° to 131°F (0° to 55 °C)
-13° to 185°F (-25° to 85 °C)
5% to 95%, non-condensing
No corrosive gases permitted
35mm DIN rail/None
Conforms to EN 60068-2-6
Conforms to EN 60068-2-27
Conforms to EN 61000-6-2
IP20
100g (3.5 oz)
44mm x 100mm x 66.4 mm (1.73 in x 3.94 in x 2.61 in)
UL/cUL File No. E157382, CE
Hot-Swapping Information
Note: This device cannot be Hot Swapped.
Universal Field I/O
tFED-9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PX-TCP1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AutomationDirect PX-TCP1

  • Page 1 For the latest prices, please check AutomationDirect.com. 1-800-633-0405 Bus Couplers - PX-TCP1 PX-TCP1 $347.00 PX-TCP1 I/O Bus Specifications 24VDC (-15%/+20%) Supply Power for I/O Bus 70mA + (total I/O bus current) / 4 Input Current from Power Supply 10A Max...
  • Page 2 See PX-USER-M manual for complete details. Address Selection - RD– RD– The last octet or byte of the IP Address for the PX-TCP1 is set using the large bank of DIP switches BRN/WHT BRN/WHT DIP Switches on the front of the coupler. The smaller bank of DIP switches is used to select the type of address assignment (DHCP, BootP, firm setting).
  • Page 3: System Considerations

    Input Bytes and 512 Output Bytes. distance from the client to the PX-TCP1 place of a PX-TCP1 Bus Coupler. Up to 3. Do not exceed the Coupler I/O Bus Power is 330 feet (100 meters) using 24 AWG...
  • Page 4 For the latest prices, please check AutomationDirect.com. 1-800-633-0405 Bus Couplers - PX-TCP1 PX-TCP1 Wiring Connections Standard PX-TCP1 / Bus Coupler Bus Coupler PX-902 Supply Power Supply Power Terminal PX-903 PX 903 Label Label PX-MOD X X MOD X MOD X X X MOD...
  • Page 5 For the latest prices, please check AutomationDirect.com. 1-800-633-0405 Bus Couplers - PX-EIP1 PX-EIP1 $347.00 PX-EIP1 I/O Bus Specifications 24VDC (-15%/+20%) Supply Power for I/O Bus 70mA + (total I/O bus current) / 4 Input Current from Power Supply 10A Max...
  • Page 6 For the latest prices, please check AutomationDirect.com. 1-800-633-0405 Bus Couplers - PX-EIP1 Configuration Port The Service Port connector is located under the flip-cover shown (previous page graphic). This port is used for communication with the software configuration tool. The software configuration tool auto- configures the EtherNet/IP addresses of the I/O terminals while the interface allows the user to: •...
  • Page 7 For the latest prices, please check AutomationDirect.com. 1-800-633-0405 Bus Couplers - PX-EIP1 System Considerations The PX-EIP1 performs as an EtherNet/ must not be exceeded as there is no terminal passes I/O Bus communication. IP server in an EtherNet/IP network. internal overcurrent protection.
  • Page 8 For the latest prices, please check AutomationDirect.com. 1-800-633-0405 Bus Couplers - PX-EIP1 PX-EIP1 Example Network Diagram Cat5e STP cable 16.5 ft. (5m) max. length per segment PX-USB-232 PX-902 PX-903 PX-901 PX-EIP1 PC with PX-CFGSW PX-901 PX-903 PX-901 PX-EIP1 Stride Ethernet...
  • Page 9 For the latest prices, please check AutomationDirect.com. 1-800-633-0405 Bus Couplers - PX-EIP1 PX-EIP1 Wiring Connections Wire connection is made through a spring clamp style terminal. This terminal is designed for a single-conductor solid or stranded wire. Wire connection is made...
  • Page 10 For the latest prices, please check AutomationDirect.com. 1-800-633-0405 Power Budget Planning Managing Power Power Budget Example Resources The example below shows how to calculate the power budget for a typical ProtosX When determining the types and system. This example is constructed...
  • Page 11: Power Requirements

    For the latest prices, please check AutomationDirect.com. 1-800-633-0405 Power Requirements Power Supplied and Consumed These tables show the amount of power supplied by each of the Bus Couplers Power Supplied and the amount of power consumed by 5V(mA) each I/O device. The Power Consumed...
  • Page 12: Wiring Specifications

    For the latest prices, please check AutomationDirect.com. 1-800-633-0405 System Installation and Removal Bus Coupler and Bus Terminal Installation Bus Coupler Installation: 1. Attach a Bus Coupler by snapping it onto 35mm DIN rail and securing it into Insert unit using tongue and groove...
  • Page 13: Installation Considerations

    For the latest prices, please check AutomationDirect.com. 1-800-633-0405 Installation Considerations Terminal Dimensions and Spacing 1.4” Requirements 35mm Use the following diagrams to make sure the Protos X system can be installed 0.8” 20mm in your application. Protos X terminals require 35mm DIN rail for mounting;...
  • Page 14 For the latest prices, please check AutomationDirect.com. 1-800-633-0405 Installation Considerations Terminal Types Protos X Five Basic Terminal Typ TYPE 1 TYPE 2 TYPE 3 TYPE 4 I/O Bus I/O Bus I/O Bus I/O Bus contacts contacts contacts contacts Terminal Terminal...

This manual is also suitable for:

Px-eip1

Table of Contents