Product Scope & Application The eFloStop is an electronic valve for mains water systems, designed to automatically shut-off water flow in the event of a detected leak. Suitable for installation on indoor hot water systems, this valve meets the relevant standards of the Plumbing Code of Australia and WMTS-476:2016.
Page 3
Step-by-Step Installation Guide 1. Position the valve: eFloStop is non-directional and can be installed on the inlet water supply line in any orientation within 1m of the safe tray, and within 2m of a power plug (if using the optional power supply). 2.
Routine Testing Procedure 1. Manual Test: Hold down the TEST button on the sensor to close the valve, which will stop water flow. The eFloStop alarm will continue to beep and the red LEAK light will flash. Verify the Visual Indicator has turned RED and that water flow has stopped.
Page 5
Optional Power Supply Shut Off Valve Leak (Red LED) Visual Indicator Low Battery (Orange LED) RESET Button Sensor Test Button Alternative Sensor Leak Sensor Positioning Probes 1800 284 287 wattsau.com.au...
Page 6
Operation & Troubleshooting Guide Issue Cause Solution Red Light and Alarm Water in safe tray If water is present, contact (Leak Detected) a plumber. If the tray is dry, hold the RESET button to reset the system. Valve fails to reopen Sensor still detects Ensure the sensor is when RESET button is...