Do you have a question about the 1000123 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for RCT 1000123
Page 1
(oil, water and others on request) Radio range up to 500 m š Display optionally in percent or liters (4 digits) š Warning at level below 20 percent š Battery and signal monitoring of the š Radio transmitter unit Remote Control Technology RCT. Simplify monitoring.
Page 2
Power supply LCD Display Wall mount bracket Fig. 1 | Scope of delivery ITEM INFORMATION RCT Item No. 1000123 / 1000384 Name LCD DISPLAY Receiver Included • RF Receiver LCD (4-digit display) • Power supply • Wall mount bracket • Instruction manual...
LPG tanks, e.g. in the living area or office. The device receives the coded signal (868.45 MHz) from up to four RCT radio transmitters type LEVELview.BASIC.LPG (others on request) within a radius of up to 500 m. The levels can be displayed either as percentage (up to 4 tanks) or in liters (4- digit display for 1 tank).
Description of the device Signal reception Red warning LED Tank display in % Reset button (inside, can be pressed with a pointed object) Power supply connection Fig. 2 | Description of the device Symbols on the display with tank icon Tank: Signal fail Fig.
Page 5
Now compare the displayed value with the real fill level in the tank. In the case of deviations, check the correct setting and installation of the sensor and transmitter. Further information can be found in the operating instructions for the transmitter. RCT. Simplify monitoring.
Page 6
1 on the display. Note: Before programming a further transmitter, all activated RCT Radio transmitters within radio range should be temporarily disconnected from the battery so that the receiver is not mistakenly programmed to the signal of a wrong Radio transmitter.
Page 7
Example: With a total tank volume of 10 000 L, the change in level by 1 % corresponds to a liter display in 100 L steps. RCT. Simplify monitoring.
Page 8
The reference value is 50 % of the total tank volume in liters (max. 9 999 liters ÷ 2 = 5 000 liters). Example: Tank with a total tank volume of 3 000 liters. Reference value = 3 000 L ÷ 2 = 1 500 L „...
Page 9
Set the display to the current liter display “h=xxxx” by briefly pressing the reset button. Then press once for a long time (at least 5 seconds). You will enter the setting mode for the reference value which can be changed as described on page 8. RCT. Simplify monitoring.
Resetting the receiver With a complete reset (= resetting the device to the factory settings), all entries and memory location assignments are deleted. Before resetting, disconnect all active RCT radio transmitters within radio range from the battery. Resetting the liter settings If you have entered a liter value, switch to the display of the liter value “h=xxxx”...
On the back of the receiver there are two attachment holes in the housing. Use them to hang the receiver on the hooks of the wall mounting bracket. Finally, connect the power supply unit to the socket. RCT. Simplify monitoring.
Page 12
As an option Using an external receiving antenna The external receiving antenna (item 1000635 External receiving antenna 868 MHz) can be retro- fitted at any time if required. It is an active compo- nent and amplifies the received signal by 30 dB. This enables a greater range or bridging of unfavorable structural conditions.
Page 13
Receiver out of transmitters radio range „ Place receiver at a different place/use external receiving antenna/use multi- plexer to bridge longer range If you have any questions or problems, please contact your specialist supplier or the manufacturer. RCT. Simplify monitoring.
Warranty All RCT products are subject to strict quality control. If you still have reason to complain, please contact your dealer or the manufacturer. The statutory warranty in Germany covers the first two years from the date of purchase.
Radio receiver - LCD display Tank icon, consisting of the following devices: Ÿ 1000384 (1000123) RF Receiver internal antenna - LCD Display Tank icon and Ÿ Power supply adapter: Voltkraft Item No. 518305 PA 300 or Friwo Modell FW35/13DR.EU05-025...
Page 16
Your contacts If you have any questions about mounting, installation or operation or would like to get more information about our products, please contact your specialist supplier or contact RCT directly as the manufacturer. Remote Control Technology GmbH Turmstraße 15...
Need help?
Do you have a question about the 1000123 and is the answer not in the manual?
Questions and answers