EN
1D48
Carbon monoxide and flammable
gas detector
Thank you for purchasing a carbon monoxide and flammable gas detector. Please read this manual carefully and heed the safety
warnings and instructions before installing, using or repairing the equipment. This will ensure not only the protection of persons, but
also the long life of the equipment.
This product is used to detect both toxic carbon monoxide and flammable gas (e.g. liquefied petroleum gas, natural gas, methane,
etc.). This detector uses catalytic combustion method and electrochemical sensor, which is stable and reliable.
T E C H N IC A L P A R A M E TE R S
Mains power supply
Batteries
Working temperature
Working relative humidity
Concentration display
Dimensions
S T A R T -U P A N D D E S CR IP T IO N O F T H E D E V IC E
-
Connect the device to the power supply, then the light indication
will be displayed and the device will remain in this state for about
3 minutes before the device is ready for operation.
-
The LED indicator shows three states:
Power - green, Alarm - red and Fault - yellow.
G A S C O N C E N T R A T IO N D IS P LA Y
-
The LCD will display the concentration if the carbon monoxide concentration is greater than 30 PPM or the flammable gas
concentration is greater than 5% LEL (Lower Explosive Limit, which is equal to 2500 PPM).
If the carbon monoxide gas concentration is above 1000 PPM or the flammable gas concentration is above 20% LEL (equal to
10,000 PPM), the LCD display will show "HHH", indicating that the concentration is above 999 PPM.
A LA R M
Detection sensitivity in accordance with EN 50194-1:2009 / EN50291-1:2010
50PPM between 60 and 90 min.
100PPM between 10 and 40 min.
300PPM, up to 3 min.
400PPM immediately
-
If the carbon monoxide concentration is above the value, the detector will sound an alarm.
At the same time, the concentration is displayed on the LCD.
-
If the flammable gas concentration is greater than 6%LEL (equivalent to 3000PPM), the detector will sound an alarm.
At the same time, the display shows the concentration.
E R R O N E O U S E V A LU AT IO N
-
If the device detects an error while checking its status, the display will show "FAIL" and the yellow LED will flash.
AC 90 - 240 V / 50 - 60 Hz
9V, rechargeable - recommended (not included)
0-50°C
10%-95%
Carbon monoxide gas: 30PPM~999PPM Flammable gas: 5%~20% LEL
±3.%LEL(2.500PPM~10.000PPM±1, 500PPM)
112x73x42mm
LCD Display
Speaker
LED Indicator
Test button