Herutu TW-870R-EXL Instruction Manual

Pokayoke (mistake prevention) tools

Advertisement

Quick Links

POKAYOKE (MISTAKE PREVENTION) TOOLS
TW-870R-EXL
Instruction Manual V1.00
Please use this operation manual correctly on reading well.
Please keep it carefully to be able to read immediately, when required.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TW-870R-EXL and is the answer not in the manual?

Questions and answers

Summary of Contents for Herutu TW-870R-EXL

  • Page 1 POKAYOKE (MISTAKE PREVENTION) TOOLS TW-870R-EXL Instruction Manual V1.00 Please use this operation manual correctly on reading well. Please keep it carefully to be able to read immediately, when required.
  • Page 3: Table Of Contents

    Contents 1. General outline ........................ 1 2. Main part and accessories ....................2 3. Safety concerns ....................... 4 4. Specification ........................5 5. Network communication ....................6 6. Name and function of each part ..................12 7. Setting ..........................13 8.
  • Page 4: General Outline

    "TW-870R-EXL" is a receiver with LAN connection specification of TW-870 series. "TW-870R-EXL" has XPort of Lantronics Corporation as a conversion module for LAN connection. For XPort, if you would like to check the details that can’t be explained in this manual or more details, please refer to the XPort manual published by Lantronics.
  • Page 5: Main Part And Accessories

    TW-870R-EXL 2. Main part and accessories Receiver TW-870R-EXL TW-870R-EXL × 1...
  • Page 6 TW-870R-EXL Option ・AC Adapter ADB24050-C (With connecting cable 1.8m) Cable approx. 1.5m Cable approx. 1.8m ・High-Volume Buzzer TW-870R-BZ01 (Sound Pressure Minimum 103 dB at 1 m (3.3 ft)) Cable Approx. 420mm (16.5ft) / UL1007 24AWG Cable ends are pre-treated with rod terminals.
  • Page 7: Safety Concerns

    TW-870R-EXL 3. Safety concerns Safety concerns (Be sure to read) To prevent human injury of user or damage in property from occurring, be sure to observe the precautions shown below. ■ The degree in safety hazard and damage generated by the wrong usage while ignoring the descriptions is classified by the following displays.
  • Page 8: Specification

    Emission designation Frequency band 2,403MHz-2,478MHz Channel 76CH Modulation way GFSK Communication way Simplex ・Receiver TW-870R-EXL Items Specification RJ-45 Ethernet * 1 Interface 10BASE-T or 100BASE-TX (Auto sense determination) 1 Relay Output (Terminal block:M3(2P)) Contact mechanism MOS-FET/1a Output Rated load voltage AC/DC30V per point Rated load current 0.5A per point...
  • Page 9: Network Communication

    TW-870R-EXL 5. Network communication In order to connect the receiver to the network, you first need to set the network settings according to the network environment. For details of the setting method, refer to the attached "LAN Setting Manual for TW-870R-EXL".
  • Page 10 TW-870R-EXL LED monitor Activity LED Link LED No Activity No Activity Amber Half duplex Amber 10Mbps Green Full duplex Green 100Mbps...
  • Page 11 TW-870R-EXL ●Communication Specification Ethernet Interface (According to XPort specification) Interface RJ-45 Ethernet 10BASE-T or 100BASE-TX(Auto sense determination) Compatibility Ethernet Version 2.0/IEEE802.3 Protocol TCP/IP, UDP/IP Ethernet output data types are classified into two types: “Short data” and “Long data”. Set the data type with DIP switch of the receiver. For details, refer to the setting of receiver in "Setting".
  • Page 12 TW-870R-EXL Formatting short data (19byte) Fastening information, Transmitter Preamble test switch battery Checksum ID number information Data name Description Byte Preamble FFH,FFH,FFH ID number 10 digit is converted to ASCII data(Hexadecimal). Example) ”010100004A” Transmitter ID number (30H,31H,30H,31H,30H,30H30H,30H,34H,41H) 2 byte ASCII data ・When the maximum number of transmissions of the transmitter is...
  • Page 13 TW-870R-EXL Formatting long data (43byte) Data Fastening varied information, according Transmitter Maintenance Transmitter Preamble STX ETX Checksum test switch to the type Data Data ID number battery information transmitter used Data name Description Byte Preamble FFH,FFH,FFH ID number 10 digit is converted to ASCII data(Hexadecimal).
  • Page 14 TW-870R-EXL Communication specification between the receiver CPU and XPort RS-232C communication is carried out between the receiver CPU and XPort. Since the internal communication protocol is as follows, please refer to when checking XPort communication setting. The RS - 232C protocol is as follows:...
  • Page 15: Name And Function Of Each Part

    TW-870R-EXL 6. Name and function of each part ・Receiver TW-870R-EXL 1.Power switch For power ON and OFF 2.Terminal block of power Terminal block for power source of DC24V(M3) source 3.DIP Switch 1 For setting DIP switch (6 selection) For setting DIP switch (6 selection) 4.DIP Switch 2...
  • Page 16: Setting

    TW-870R-EXL 7. Setting It needs doing “pairing” a transmitter and a receiver before using. The number of transmitters which can register pairing to one set of a receiver does not have restriction. ID number of receiver is memorized in transmitter. Transmitter transmits the signal included ID number of receiver.
  • Page 17 TW-870R-EXL ●Setting of receiver You can set “relay output time”, “Double count protect time”, “Behavior of buzzer” by 6-position DIP switch. Please set by your operation. When setting or changing DIP switches, be sure to do so with the power OFF.
  • Page 18 TW-870R-EXL DIP switch 3 (Extension unit side) DIP switch 3 - 1 and 2 of the extension unit set the communication speed and flow control of the internal CPU ⇔ XPort. In this receiver, since the setting between built-in CPU and XPort is done at the time of shipment, if there is no special reason, please do not change the setting.
  • Page 19: How To Use

    TW-870R-EXL 8. How to use 1. Power switch of receiver is turned on. Please confirm the LED situation as turning off. When the LED for receiving turns on, the transmitter is not registered by pairing. Please make a pairing with transmitter.
  • Page 20 TW-870R-EXL ●Test switch There is a test switch for checking the battery and communication. When the transmitter transmits the signal by test switch not limit switch, receiver doesn’t output relay output. But LED of the receiver only turns on. Also, transmitter make a checking the battery at pushing the test switch.
  • Page 21 TW-870R-EXL ●Communication Monitor The receiver body has a monitor LED that displays the communication status between the internal CPU and the XPort, and displays the following depending on the communication status. Explanation TXD(Green) The green LED lights up while sending data.
  • Page 22 TW-870R-EXL ●Delete the channel table When radio interference id occurring, you can change the channel used for wireless communications by deleting the channel table. How to delete the channel table: 1.Turn DIP Switch 3-6 on the side of the main unit to ON.
  • Page 23: Note On Use

    TW-870R-EXL 9. Note on use ■Caution for communication ・If the transmitters transmit at the same time without any difference of 1 msec, one receiver can receive up to four transmitters. ・The receiver has a buffer that temporarily holds the data sent from the transmitter. The buffer can store up to 107 short data and 47 long data.
  • Page 24: Dimensional Drawing

    TW-870R-EXL 10. Dimensional drawing ・Receiver TW-870R-EXL...
  • Page 25: After Service And Warranty

    This regulation (hereinafter referred to as the "Regulation") is for post-shipment warranty provided by HERUTU ELECTRONICS CORPORATION (hereinafter referred to as the "Company") so that you can use the Company's product you have purchased with confidence. The Regulation does not apply to special order products (custom products).
  • Page 26 This regulation (hereinafter referred to as the "Regulation") shall be applied to paid repair service (hereinafter referred to as the "Service") provided by HERUTU ELECTRONICS CORPORATION (hereinafter referred to as the "Company"). The Regulation does not apply to special order products (custom products). In addition, purchased products shall be subject to relevant manufacturer's repair regulations, and the Regulation shall not apply.
  • Page 27 TW-870R-EXL Establishment of contract The contract shall be established when the customer approves the quotation presented by the Company and issues an order form before the end of the repair implementation period. Purpose of the Service The Company will provide the Service for the purpose of repairing the function and performance of the Company's product used by the customer if it fails beyond the scope of the warranty specified in the warranty regulation.
  • Page 28 TW-870R-EXL the failure, it will return the Product for repair to the customer. In addition, if the customer does not place an order within three months from the date of creation of the quotation, or if the customer does not accept the quotation and the customer expresses an intention not to carry out the repair, the Company will assume that the customer has canceled the request for the Service, and the Company will return the Product for repair to the customer without carrying out the repair.
  • Page 32 HERUTU ELECTRONICS CORPORATION 422-1 Higashimikata-cho, Chuo-ku, Hamamatsu, Shizuoka, 433-8104 Japan (Sales dept) TEL.+81-53-438-3555 FAX. +81-53-438-3411 Website URL https://www.herutu.co.jp/en/ E-mail info@herutu.co.jp...

Table of Contents