  • Page 1 S Series Motors Model S6 Operation & Parts Manual P/N 108004 Rev 5...
  • Page 2: Eu Declaration Of Conformity

    EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements as specified by the EU Directives listed. The product may not be taken into service until it has been established that the drive motor for the centrifugal pump complies with the provisions of all relevant EU Directives.
  • Page 3 EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements as specified by the EU Directives listed. The product may not be taken into service until it has been established that the drive motor for the centrifugal pump complies with the provisions of all relevant EU Directives.
  • Page 4: Declaration Of Conformity

    Declaration of Conformity Finish Thompson Inc. hereby declares that the following electrical equipment fully complies with the applicable health and safety requirements as specified be the UKCA directives listed. The product may not be taken into service until it has been established that the driven Drum and Container Pump complies with the provisions of all relevant UKCA Directives provided pumps manufactured by Finish Thompson are used.
  • Page 5 Declaration of Conformity Finish Thompson Inc. hereby declares that the following electrical equipment fully complies with the applicable health and safety requirements as specified be the UKCA directives listed. The product may not be taken into service until it has been established that the driven Drum and Container Pump complies with the provisions of all relevant UKCA Directives provided pumps manufactured by Finish Thompson are used.
  • Page 6 Finish Thompson, Inc. 921 Greengarden Rd. Erie, PA 16501 U.S.A. Tel. 1-814-455-4478 Fax 1-814-455-8518 www.finishthompson.com fti@finishthompson.com Index Introduction ………………………………………………………………………….. 6 General Terms & Conditions, Warranty ………………………………………………… 7 Safety ……………………………………….………………………………………..8-9 Important Safety Information for Pumping Flammable or Hazardous Substances ………...10 Installation …………………………………………………………………………... 11 Motor Operation………....…….……………...………………………..……12...
  • Page 7: Warranty Registration

    Warranty, General Terms & Conditions 1. The following terms and condition apply to the sale of machinery, components and related services and products, of Finish Thompson, Inc. (hereinafter “the products”) 2. Finish Thompson, Inc. (the manufacturer) warrants only that: a.) its products are free of defects in material, design and workmanship at the time of original purchase; b.) its products will function in accordance with Finish Thompson, Inc.
  • Page 8: Battery Safety Information

    Safety Lithium Ion Battery Advantages The advanced lithium ion batteries contained in the S6 drum pump motor have several major advantages compared to older technologies like nickel cadmium (NiCd) or nickel metal hydride (NiMH). • They have much higher energy density compared to NiCd or NiMH. This results in a significantly lighter battery. The battery used in the S6 is extremely powerful for its compact size and weight.
  • Page 9: Battery Disposal

    • Never place metal objects in the motors charging port. A short circuit could occur allowing the motor’s battery pack to generate excess heat, explode or ignite. • The battery can be recharged at any state of battery discharge. It does not have to be completely discharged before charging and does not suffer the “memory effect”...
  • Page 10 IMPORTANT SAFETY INFORMATION FOR PUMPING FLAMMABLE OR HAZARDOUS SUBSTANCES Read these instructions before operating the pump and motor equipment. The manufacturer will not be responsible for any damage to property or to persons caused by improper use of the equipment. WARNING: It is the responsibility of the user to operate the pump in conformance with OSHA rules for dispensing liquids.
  • Page 11: Installation

    Installation 1. Unpack motor and pump tube from carton. Check for shipping damage. If damage is detected, save the packaging and notify the carrier immediately. 2. If motor and pump tube are boxed separately, the motor will need to be fastened to the pump tube. See figure 1. 3.
  • Page 12: Motor Operation

    Motor Operation Note: The motor has been partially charged and should be fully charged prior to use. Warning: The motor is NOT suitable for hazardous locations or pumping flammable or combustible materials. 1. Verify that the motor switch is in the center “O” OFF position. See Figure 6. Figure 6 2.
  • Page 13: Troubleshooting

    Battery Pack Removal for Recycling If your battery pack will no longer hold a charge, you can either purchase a replacement battery pack or a new S6 motor assembly. To recycle your old battery pack, please follow these instructions: 1. Make sure the motor switch is in the OFF position before beginning. 2.
  • Page 14 Wall Hanger Instructions Figure A Figure B If you ordered the optional Wall Hanger p/n 108287 or received it in one of our kits please follow these instructions for installation & use: 1. If using the 115v or 230v Quick Charger you may store it inside the Wall Hanger. Simply align the charger cables with the slots on the wall hanger making sure the indicator light lines up with the hole on the front of the wall hanger.
  • Page 15: Technical Data

    Technical Data Motor Specifications Performance (on water) Rechargeable Motor (2 speed) Full Speed Specifications Model S6 Low Speed Battery Voltage 12 volts* (10.8 volts) Battery Capacity/Type 5,000 mAh/Lithium Ion Input/Output Power 150/100 Watts Duty Cycle Continuous RPM (low/high speed) 8,000/12,000 14 gpm(53 lpm) @ high speed Maximum Flow 8 gpm (30 lpm) @ low speed...
  • Page 16 Item Quantity Description Part Number Motor cover & fan assembly 108301 Flammables warning label 108148 Switch 107304 Jack cover 108219 Jack nut 108220 DC power jack 107958 Stainless steel flat washer 107974 Battery pack assembly 108302 Flag terminal 107972 Motor & canister assembly 108300 Stainless steel flat washer 107125...