Page 1
U SER INS T RU C TION S Installation Operation Maintenance 682M and 682H Seal Coolers Experience In Motion...
Page 2
“warning” is not obeyed. This manual is intended to ensure the safe installation and effective operation of the 682M and 682H seal More specific icons are also used, depending on the coolers. It is highly recommended that all applicable type of hazard.
Design Overview (PPE), according to plant regulations. 5.1. Description Environmental Considerations The 682M and 682H Seal Coolers are shell and tube heat exchangers used to lower the temperature of single CAUTION and dual mechanical seals. The medium to be cooled is...
682HPFF0600 ASME², PED³ 1 The 682*BTN cooler versions are for Flowserve systems internal use only (see page 4) 1 Add suffix -U to part number for ASME U-Stamp (Example: 682MSTN0000-U) 1 Add suffix -P to part number for PED Certification (Example: 682HSNN0000-P) SSIOM001989 (EN/AQ) October 2024 Flowserve.com 4...
682M and 682H Seal Coolers 7.3. Vertical or Horizontal Mounting It is strongly recommended that the 682M and 682H Seal Coolers be mounted in a vertical position to ensure proper cooling efficiencies and simplify maintenance requirements. Even though the 682M and 682H Seal Coolers can...
Seal cooler performance should be periodically 9.3. Remove the center bolt. validated. Baseline temperatures should be gathered 682M: Remove two snap rings located between the coil soon after equipment commissioning and compared fittings and the top cover. with temperature data collected periodically over the operational life of the cooler.
Page 9
Headquarters Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its Flowserve Corporation useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions.