Air management system
Table of Contents

Advertisement

Quick Links

User Manual
SIGMA AIR MANAGEMENT SYSTEM
SBU
No.: 901736 07 USE
Manufacturer:
KAESER KOMPRESSOREN SE
96410 Coburg • PO Box 2143 • GERMANY • Tel. +49-(0)9561-6400 • Fax +49-(0)9561-640130
www.kaeser.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIGMA SBU and is the answer not in the manual?

Questions and answers

Summary of Contents for KAESER KOMPRESSOREN SIGMA SBU

  • Page 1 User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE Manufacturer: KAESER KOMPRESSOREN SE 96410 Coburg • PO Box 2143 • GERMANY • Tel. +49-(0)9561-6400 • Fax +49-(0)9561-640130 www.kaeser.com...
  • Page 2 /KKW/CSAM 2.08 en Z1 IBA-901736 /KKW/CSAM 2.08 Z1 20181207 092039...
  • Page 3: Table Of Contents

    Contents Regarding this Document Using this document ......................Copyright .......................... Licensed brands and trademarks ..................Symbols and labels ......................1.4.1 Warnings ......................1.4.2 Potential damage warnings ................1.4.3 Other alerts and their symbols ................Technical Data System data ........................Electrical Data ........................Versions and Options .......................
  • Page 4 Contents 6.9.1 Wiring the control cabinet ................... 6.9.2 Feeding cables and connecting the screening ........... 6.9.3 Laying the cables in the control cabinet ............. 6.9.4 Connecting the cables ..................Initial Start-up Commissioning SBU 200 ....................Commissioning SBU 400 ....................Operation Operation SBU .........................
  • Page 5 List of Illustrations Fig. 1 SBU – Example of possible components ................... Fig. 2 Application examples with converter SBU200-1 DSL ..............Fig. 3 The cable length depends on the data rate and cross-section for a 2-wire cable ...... Fig. 4 Strip the isolation from the network cable ..................
  • Page 6: List Of Illustrations

    List of Illustrations User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 7 List of Tables Tab. 1 Danger levels and their definitions (personal injury) ..............Tab. 2 Danger levels and their definition (damage to property) ............Tab. 3 System data ..........................Tab. 4 Electrical Data ..........................Tab. 5 SBU types for wall mounting ...................... Tab.
  • Page 8: List Of Tables

    List of Tables User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 9: Regarding This Document Using This Document

    Regarding this Document Using this document 1 Regarding this Document Using this document The operating manual contains important information to the entire life cycle of SBU. The operating manual is a component of the product. ➤ Keep the manual in a safe place throughout the life of SBU. ➤...
  • Page 10: Potential Damage Warnings

    Regarding this Document Symbols and labels These show the kind of danger and its source. The possible consequences of ignoring a warning are shown here. If you ignore the warning notice, the "WARNING" signal word indicates a lethal or severe in‐ jury will occur.
  • Page 11 Regarding this Document Symbols and labels Information referring to potential problems is identified by a question mark. The cause is named in the help text ... ➤ ... as is a solution. This symbol identifies important information or measures concerning environmental protec‐ tion.
  • Page 12: Technical Data System Data

    Technical Data System data 2 Technical Data System data ➤ Enter the system data of this product in the following table. System data Value Part number Serial number Tab. 3 System data The part number and serial number is provided on the nameplate. Electrical Data Model SBU 400 —...
  • Page 13 Technical Data Versions and Options Description Converter 7.9691. SBU200-1_OLM2 07000 Converter 7.9681.1 SBU400-1 Converter 7.9681. SBU400-1_PT 10010 Converter 7.9681. SBU400-1_FC 10020 Converter 7.9681. SBU400-1_DHS 10030 Converter 7.9681. SBU400-1_II 10040 Converter 7.9681. SBU400-1_SW 12000 Converter 7.9681. SBU400-1_OLM 14000 Converter 7.9681. SBU400-1_OLM2 17000 Converter 7.9681.
  • Page 14: Components Within The Control Cabinet

    Technical Data Components within the control cabinet Description Converter 7.9684. SBU400-4_SW 12000 Converter 7.9684. SBU400-4_SWII 12010 Tab. 5 SBU types for wall mounting Components within the control cabinet 2.4.1 I/O-Modules (SIGMA AIR MANAGER 4.0 and SBU) The following technical data apply to the I/O block and the individual I/O modules used in SIGMA AIR MANAGER 4.0 and SBU: ■...
  • Page 15: Tab. 7 Technical Data, I/O-Block And Individual Modules

    Technical Data Components within the control cabinet Feature Value Bus Controller X20BC0087-C01 Max. length of the line between SIGMA NETWORK two components [ft.] Potential isolation SIGMA NETWORK I/O-mod‐ 24 V DC power supply X20PS9400 Power supply [V DC], [A] 24 (-15% / +20%), max. 0.7 Potential isolation —...
  • Page 16: I/O Modules (Only Sbu)

    Technical Data Components within the control cabinet 2.4.2 I/O Modules (only SBU) The following technical data apply to the individual I/O modules used only in SBU: Feature Value Connection terminals Push-in terminal Connection cross-section Copper wires ■ Wire/single-core [AWG] ■ AWG 28-14 ■...
  • Page 17: Relay Block

    Technical Data Components within the control cabinet 2.4.2.3 Module 4AIP – X20AP3121 Feature Value Voltage, analogue inputs ■ Max. rated voltage, Phase-Phase [V AC], ■ 480 at 50/60 [Hz] ■ ■ Max. rated voltage, Phase-N [V AC] ■ 1.5xU permanent, 2xU for 1 minute ■...
  • Page 18: Switch 8 Port

    Technical Data Components within the control cabinet Feature Value Connection cross-section Copper wires Copper wires ■ Wire/single-core [AWG] ■ 0.14-1.5 / AWG 24-16 ■ 0.5-4 / AWG 20-12 ■ Flex/fine-core [AWG] ■ 0.14-1.5 / AWG 24-16 ■ 0.5-2.5 / AWG 20-14 ■...
  • Page 19: Sigma Network Switch 4-Port Rj45 - 1-Port Foc

    Technical Data Components within the control cabinet 2.4.5 SIGMA NETWORK Switch 4-port RJ45 – 1-port FOC Feature Value Port RJ45: SIGMA NETWORK Transfer rate [Mbps] 10/100 Characteristics Auto crossing (Auto-MDI(X) ), Auto negotiation, Auto sensing Connections RJ45, 10/100Base-TX Max. length of the line between SIGMA NETWORK two compo‐...
  • Page 20: Ethernet Extender

    Technical Data Components within the control cabinet Feature Value Display elements Status LED Service interfaces Mini USB, slot for MMC memory card, rotary switch Tab. 16 Data, SNW/DP bus controller 2.4.7 Ethernet extender The Ethernet extender makes broadband Ethernet applications possible on existing cables. You can use company-owned 2- and 4-wire cables.
  • Page 21: Control Cabinet

    Technical Data Control cabinet Control cabinet Model SBU 400-1 Material Sheet metal, painted RAL 7035 light-grey Width [in.] Height [in.] Depth [in.] Weight [lb.] Enclosure protection IP54 (IEC 529) Tab. 18 Control cabinet data User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 22: Safety And Responsibility Basic Instructions

    Safety and Responsibility Basic instructions 3 Safety and Responsibility Basic instructions Disregarding these instructions can result in serious injury. ➤ To safely operate this product, carefully read the operating manual and take notice of its contents. The product SBU is manufactured to the latest engineering standards and acknowledged safety regulations.
  • Page 23: User's Responsibilities

    Safety and Responsibility User's responsibilities User's responsibilities 3.4.1 Observe statutory and universally accepted regulations ➤ Observe relevant statutory and accepted regulations during installation, operation and mainte‐ nance of the control cabinet and its components. 3.4.2 User's Responsibilities These are people who, by virtue of their training, knowledge and experience as well as their knowl‐ edge of relevant regulations can assess the work to be done and recognize the possible dangers involved.
  • Page 24: Safe Sbu Operation

    Safety and Responsibility Warranty ➤ Check and ensure that no voltage is present. ➤ Before switching on again make sure that ■ no maintenance personnel are working on the machine, ■ all panels are in place, ■ all access doors are closed. ➤...
  • Page 25 Safety and Responsibility Warranty Correct maintenance and repair means the use of genuine Kaeser spare parts. ➤ Obtain confirmation from KAESER that your specific operating conditions are suitable. User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 26: Design And Function Overview

    Design and Function Overview 4 Design and Function Overview The SBU (SIGMA NETWORK BUS CONVERTER) is an interface expansion for SIGMA AIR MANAGER 4.0. Use SIGMA NETWORK to connect SBU with SIGMA AIR MANAGER 4.0. SBU is offered in different designs. They differ by the number of the factory-installed components. Fig.
  • Page 27: Fig. 2 Application Examples With Converter Sbu200-1 Dsl

    Design and Function Converter SBU200-1 DSL Fig. 2 Application examples with converter SBU200-1 DSL SIGMA AIR MANAGER 4.0 2-wire cable (e.g. PROFIBUS line) or 4- Ethernet line wire line SIGMA NETWORK cable Customer LAN Converter SBU200-1 DSL KAESER compressor with SIGMA NETWORK User Manual SIGMA AIR MANAGEMENT SYSTEM...
  • Page 28: Installation And Operating Conditions

    Installation and Operating Conditions Environment 5 Installation and Operating Conditions Environment Temperature range Ambient temperatures Min. ambient temperature Maximum ambient temperature 0 °C 45 °C Tab. 19 Ambient temperatures Storage temperatures Minimum storage temperature Maximum storage temperature −20°C 70°C Tab. 20 Storage temperatures Note permissible ambient temperatures: 1.
  • Page 29: Installation

    Installation Ensuring safety 6 Installation Ensuring safety Follow the instructions below for safe installation. Warning instructions are located before a potentially dangerous task. Disregard of warning instructions can cause serious injuries! Complying with safety warnings Disregard of safety notes can cause unforeseeable dangers! ➤...
  • Page 30: Identifying The Machines

    Installation Identifying the machines Pay attention to the following when fitting the control cabinet: ■ The fixing materials must be compatible with the type of wall and the weight of the control cabinet (chapter 2 Technical Specification). ■ The control cabinet must be fully accessible. ■...
  • Page 31: Cable Length With Copper Dsl

    Installation Planning the wiring Type Maximum cable length [ft.] Remark SIGMA NETWORK (cop‐ Maximum conductor length be‐ per Ethernet) tween two devices at the SIGMA NETWORK. SIGMA NETWORK fibre- 9800 Maximum conductor length be‐ optic cable tween two SBU with OLM design or option Digital transistor outputs Digital relay outputs...
  • Page 32: Laying Cables

    Installation Laying cables Fig. 3 The cable length depends on the data rate and cross-section for a 2-wire cable Cross-section of AWG diameter [mm] Cross-section [mm 0.08 0.32 0.16 0.46 0.41 0.72 1.31 1.29 Tab. 23 Legend for Fig. 3 With cables of a higher quality and cables with larger cross-sections greater ranges can be ach‐...
  • Page 33: Installing The Rj45 Bus Connector

    Installation Installing the RJ45 bus connector 3. Observe all accepted safety regulations and national legislation applicable to all work carried out on the SIGMA AIR MANAGER 4.0 / SBU. 4. Have SIGMA AIR MANAGER 4.0/SBU connected to the power supply by an authorized and qualified electrician to national legislation and the regulations of the electricity company con‐...
  • Page 34: Fig. 5 Inserting The Network Cable Conductors

    Installation Installing the RJ45 bus connector 1. Stripping the network cable isolation (see Fig. 4). The RJ45 plug and the network cable can be damaged if unlocked under strain. ➤ Always release strain on the RF45 plug prior to unlocking. 2.
  • Page 35: Connecting Lines

    Installation Connecting lines Fig. 8 Rotating the locking piece to the stop RJ45 plug (view from cable end) Screwdriver 6. Insert a screwdriver with 0.1 in. blade width into the bore and rotate the locking piece clockwise up to the end stop. Contact issues with conductor ends after multiple contact is created.
  • Page 36: Feeding Cables And Connecting The Screening

    Installation Connecting lines 6.9.2 Feeding cables and connecting the screening Fig. 9 Feeding cables Metal screw fitting for screened conduc‐ Plastic cable glands for fibre-optic conduc‐ tors (analogue inputs and outputs, tors. SIGMA NETWORK, PROFIBUS) Ferrite for digital inputs Plastic cable glands for unscreened ca‐ bles (common supply line, equipotential bonding, digital inputs and outputs) 1.
  • Page 37: Laying The Cables In The Control Cabinet

    Installation Connecting lines 6.9.2.1 Attaching the ferrite sleeves Ferrite sleeves may touch each other. Ferrite sleeves may be placed on the plastic gland plate or fastened to the cable at any location. ➤ Feed the conductors for digital inputs through one of the loosely-supplied ferrite sleeves 6.9.3 Laying the cables in the control cabinet 1.
  • Page 38: Initial Start-Up 7.1 Commissioning Sbu 200

    Initial Start-up Commissioning SBU 200 7 Initial Start-up Commissioning SBU 200 Precondition All installation activities and wiring tasks have been properly and completely performed according to chapter 6"Installation" 1. Switch on the safety cut-out in the SBU. 2. Close the control cabinet. 3.
  • Page 39: Operation Sbu

    Operation Operation SBU 8 Operation Operation SBU For details regarding the operation of SBU, please refer to the operating instructions for SIGMA AIR MANAGER 4.0 in chapter Operation. Display elements and interfaces of SBU with DSL An Ethernet extender is included in converter SBU200-1 DSL. The indicator elements and interfa‐ ces are described below.
  • Page 40 Operation Display elements and interfaces of SBU with DSL Location Description Remark LED LINK DSL A LED off: DSL port inactive (green) LED flashes briefly (every 3 s): DSL port searches for link partner LED LINK DSL B LED flashes (1 Hz): Link partner found (green) LED flashes (2 Hz): Initialization of connection LED flashes (4 Hz): ERR on / STAT DSL off = installation error, e.g.
  • Page 41: Fault Recognition And Rectification

    Fault Recognition and Rectification Faults and troubleshooting 9 Fault Recognition and Rectification Faults and troubleshooting For details regarding the fault detection and troubleshooting of SBU, please refer to the oper‐ ating instructions for SIGMA AIR MANAGER 4.0 in chapter Fault Recognition and Rectification.
  • Page 42: 10 Spares, Operating Materials, Service

    Spares, Operating Materials, Service 10.1 Note the nameplate 10 Spares, Operating Materials, Service 10.1 Note the nameplate The nameplate contains all information to identify this product. This information is essential to us in order to provide you with optimal service. ➤...
  • Page 43: 11.1 Decommissioning, Storage And Transport

    Decommissioning, Storage and Transport 11.1 De-commissioning 11 Decommissioning, Storage and Transport 11.1 De-commissioning De-commissioning is necessary, for example, under the following circumstances: ■ SBU is temporarily not needed. ■ SBU is to be moved to another location. 1. Isolate SBU (power supply disconnecting device) from all power phases . 2.
  • Page 44: 12 Annex

    Annex 12.1 Anchor holes for the control cabinet 12 Annex 12.1 Anchor holes for the control cabinet See instructions in chapter 6.4 Fig. 12 Anchor holes for the SBU 400 control cabinet SBU 16 in. 1 in. 12 in. 0.3 in. Ø 12.2 Installation accessories The installation accessories are shown in the operating manual of the SIGMA AIR...
  • Page 45 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 46 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 47 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 48 Annex 12.3 Electrical Diagram electrical component parts list SBU400-1 SBU400-1_PT SBU400-1_FC SBU400-1_DHS model machine power supply 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 24 V ±10 %, DC...
  • Page 49 Annex 12.3 Electrical Diagram electrical component parts list SBU400-1_SW SBU400-1_OLM SBU400-1_DP SBU400-1_SWDP model machine power supply 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 24 V ±10 %, DC...
  • Page 50 Annex 12.3 Electrical Diagram electrical component parts list SBU400-1_OLMDP SBU400-1_OLMSW model machine power supply 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 100-240 V ±10 %, 60 Hz 1) 24 V ±10 %, DC 24 V ±10 %, DC 24 V ±10 %, DC 24 V ±10 %, DC I/O-Module 7.9631.0 7.9631.0...
  • Page 51 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 52 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 53 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 54 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 55 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 56 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 57 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 58 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 59 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 60 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 61 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 62 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 63 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 64 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 65 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 66 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 67 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 68 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 69 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 70 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 71 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 72 Annex 12.3 Electrical Diagram User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 73: I/O Block 6Di & 6Dot & 4 Aii With Relays

    Annex 12.4 I/O block 6DI & 6DOT & 4 AII with relays 12.4 I/O block 6DI & 6DOT & 4 AII with relays Enter the wiring information of the actual application into the following tables. User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 74: Tab. 25 Sample Entry In Assignment Table I/O Block With Relays

    Annex 12.4 I/O block 6DI & 6DOT & 4 AII with relays Sample entry in assignment table Tab. 25 Sample entry in assignment table I/O block with relays User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 75: Tab. 26 Assignment I/O Block - Module 1: X1 Di1.X - 20Di6371 - 6X Di 24Vdc

    Annex 12.4 I/O block 6DI & 6DOT & 4 AII with relays Module 1: X1 DI1.x Tab. 26 Assignment I/O block – Module 1: X1 DI1.x – 20DI6371 – 6x DI 24VDC User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 76 Annex 12.4 I/O block 6DI & 6DOT & 4 AII with relays Module 2: X2 DOT2.x (wiring when shipped) User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 77 Annex 12.4 I/O block 6DI & 6DOT & 4 AII with relays User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 78: Tab. 27 Assignment I/O Block - Module 2: X2 Dot2.X - X20Do6322 - 6X Relays

    Annex 12.4 I/O block 6DI & 6DOT & 4 AII with relays Tab. 27 Assignment I/O block – Module 2: X2 DOT2.x – X20DO6322 – 6x relays User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 79: Tab. 28 Assignment I/O Block Modules 3 & 4 - X3 & X4 Aii3.X - X20Ai4632-1 - 4X Aii 0-22Ma 16Bit & X20Pd2113

    Annex 12.4 I/O block 6DI & 6DOT & 4 AII with relays Modules 3 & 4: X3 & X4 AII3.x Tab. 28 Assignment I/O block Modules 3 & 4 – X3 & X4 AII3.x – X20AI4632-1 – 4x AII 0-22mA 16Bit & X20PD2113 User Manual SIGMA AIR MANAGEMENT SYSTEM...
  • Page 80: Module 6Di - Digital Inputs

    Annex 12.5 Module 6DI – Digital inputs 12.5 Module 6DI – Digital inputs Enter the wiring information of the actual application into the following table. If you require more than table, please use this table to create photocopies. User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 81: Tab. 29 Assignment Module 6Di - X20Di63716X - Di 24Vdc

    Annex 12.5 Module 6DI – Digital inputs Module __: X__ DI__.x Tab. 29 Assignment Module 6DI – X20DI63716x – DI 24VDC User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 82: Module 2Dii - Digital Inputs Impulse

    Annex 12.6 Module 2DII - Digital inputs impulse 12.6 Module 2DII - Digital inputs impulse Enter the wiring information of the actual application into the following table. If you require more than table, please use this table to create photocopies. User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 83: Tab. 30 Assignment Module 2Dii - X20Di2377

    Annex 12.6 Module 2DII - Digital inputs impulse Module __: X__ DII__.x Tab. 30 Assignment Module 2DII – X20DI2377 User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 84: Module 6Dot - Digital Outputs 24Vdc 0.5A

    Annex 12.7 Module 6DOT – Digital outputs 24VDC 0.5A 12.7 Module 6DOT – Digital outputs 24VDC 0.5A Enter the wiring information of the actual application into the following table. If you require more than table, please use this table to create photocopies. User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 85: Tab. 31 Assignment Module 6Dot - X20Do6322 - 6X Dot 24Vdc 0,5A

    Annex 12.7 Module 6DOT – Digital outputs 24VDC 0.5A Module __: X__ DOT__.x Tab. 31 Assignment Module 6DOT – X20DO6322 – 6x DOT 24VDC 0,5A User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 86: Module 4Aii - Analogue Inputs 0-22Ma

    Annex 12.8 Module 4AII – Analogue inputs 0-22mA 12.8 Module 4AII – Analogue inputs 0-22mA Enter the wiring information of the actual application into the following table. If you require more than table, please use this table to create photocopies. User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 87: Tab. 32 Assignment 4Aii - X20Ai4632-1 - 4X Aii 0-22Ma 16Bit & X20Pd2113

    Annex 12.8 Module 4AII – Analogue inputs 0-22mA Module __ & __: X__ & X__ AII __.x Tab. 32 Assignment 4AII – X20AI4632-1 – 4x AII 0-22mA 16Bit & X20PD2113 User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 88: Module 4Air - Analogue Inputs Pt100

    Annex 12.9 Module 4AIR – Analogue inputs PT100 12.9 Module 4AIR – Analogue inputs PT100 Enter the wiring information of the actual application into the following table. If you require more than table, please use this table to create photocopies. User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 89: Tab. 33 Assignment Module 4Air - X20At4222

    Annex 12.9 Module 4AIR – Analogue inputs PT100 Module __: X__ AIR __.x Tab. 33 Assignment Module 4AIR – X20AT4222 User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 90: Module 2Aoi - Analogue Outputs 0-20Ma

    Annex 12.10 Module 2AOI – Analogue outputs 0-20mA 12.10 Module 2AOI – Analogue outputs 0-20mA Enter the wiring information of the actual application into the following table. If you require more than table, please use this table to create photocopies. User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 91: Tab. 34 Assignment Module 2Aoi - X20Ao2632

    Annex 12.10 Module 2AOI – Analogue outputs 0-20mA Module __: X__ AOI__.x Tab. 34 Assignment Module 2AOI – X20AO2632 User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 92: Module 4Aip - Power Measurement

    Annex 12.11 Module 4AIP – Power measurement 12.11 Module 4AIP – Power measurement Enter the wiring information of the actual application into the following table. If you require more than table, please use this table to create photocopies. User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 93: Tab. 35 Assignment Module 1Aip - X20Ap3121

    Annex 12.11 Module 4AIP – Power measurement Module __: X__ AIP__.x Tab. 35 Assignment Module 1AIP – X20AP3121 User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 94: Relay 6X - Digital Outputs Relay 1 Converter 6A

    Annex 12.12 Relay 6x - Digital outputs Relay 1 Converter 6A 12.12 Relay 6x - Digital outputs Relay 1 Converter 6A Enter the wiring information of the actual application into the following table. If you require more than table, please use this table to create photocopies. User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 95 Annex 12.12 Relay 6x - Digital outputs Relay 1 Converter 6A Module __: X__ DOT__.x User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 96: Tab. 36 Assignment Relay 6X - X20Do6322 - 6X Dot 24Vdc 0,5A

    Annex 12.12 Relay 6x - Digital outputs Relay 1 Converter 6A Tab. 36 Assignment relay 6x – X20DO6322 – 6x DOT 24VDC 0,5A User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...
  • Page 97: Hub

    Annex 12.13 Hub 12.13 Enter the wiring information of the actual application into the following table. If you require more than table, please use this table to create photocopies. Switch __: K __ Input Conductor Destination Port 1 Port 2 Port 3 Port 4 Port 5...
  • Page 98 Annex 12.13 Hub User Manual SIGMA AIR MANAGEMENT SYSTEM No.: 901736 07 USE...

This manual is also suitable for:

Sigma sbu200-1Sigma sbu200-1 dslSigma sbu200-1 swSigma sbu200-1 olmSigma sbu400-4 swSigma sbu400-4 swii ... Show all

Table of Contents