Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Front Glass Wall Note: Please read manual before construction. All drawing are for illustrative purposes only...
Installation, Operation & Maintenance Manual Tools Needed Measuring Tape Marker Pen Circular Saw Water Level Hammer Screwdriver Drill Cresent Wrench Utility Knife Rubber Mallet Ratchet Strap Many steps in the construction require lifting heavy and or bucky items, MrSteam recommends construction be done by no lee than two people Extra Hands All drawing are for illustrative purposes only...
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Details List 1/5 DET 1 K-PT-JAL-226D DET A K-STL117/1800 DET 2 T-STL117/2000XLM01 DET W kmpl MU-TRAPP DET 3 T-STL117/2000-01 DET S TKE-PR-226-12/15 DET T T-SL117/710UK2 DET U1 K-TL94/2200 DET V "...
Page 7
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Details List 2/5 DET Y2 T-PTS-226/28-P DET U2 K-TL94/2000 DET 6 Det.3 jääk T-STL117/2000XL-01 DET Ga/b/c/d Lõigata uhest STL-ist " 34" T-STL117/2000KO-01 38" DET B MU-VIT7040-KLZN DET G MU-VENT-100-PU DET F MU-VENT-100-ZN DET 10/a...
Page 8
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Details List 3/5 DET 10b T-HP44/650XP DET 10c T-HP44/170 DET 12/1 TL-LAMOD-1791/210P DET 12/2 TL-LAMOD-1791/210V DET 12a T-HP44/250XP-XP DET 14 TL-PÕMOD-1730/720 DET 11 TL-STMOD-1760-01 DET 15a TL-LAV90/670XP DET 15b TL-LAV42/90 DET 15c TL-LAV42/770XP...
Page 9
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Details List 4/5 DET 15b TL-LAV90/870 DET 21 U-KL-7/19-PR DET 21c K-HP44/1890 DET 21d K-HP44/780 DET 21a K-HL44/1860 DET 21b 29.53" x 1.73" x 0.71" K-HL44/1860 DET 22 T-STL-2000-XX DET N KAT-HAR-MUST DET 15b...
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) EXTERIOR Details List 5/5 KI-KERL-12-RV2 KI-USA-150-200 " Bit PH2 Torx bits T10 T15 T20 T25 x200 All drawing are for illustrative purposes only...
Page 11
Installation, Operation & Maintenance Manual IMPORTANT NOTE: Build this sauna in place, the sauna RMSBS78A (79” Depth x 89” Diameter) room should not be moved once assembled. Prepare a EXTERIOR suitable base like a patio, concrete pad, gravel base or block base for the sauna room.
Page 12
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) 2x DET W 2x M DET 2 Marking on DET 1 Measurements should be equal DET 3 All drawing are for illustrative purposes only...
Page 13
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Use rubber mallet! 16x M All drawing are for illustrative purposes only...
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Front Glass-Wall Assembly Inside Attention! Place inside upwards Outside Outside will have an extra notch around the edge 4x V min.1” 16x J min.3/4” min.1” Attention! Be extra careful to not hit the glass!!! 4x I min.3/4”...
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Wooden Back Wall Assembly Use rubber mallet! 4x H Pre-drill holes 5/32” Pre-drill holes 5/32” before screws before screws 4x I 2x H All drawing are for illustrative purposes only...
Page 16
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) DET U1 inside Use waterlevel 2x H Make sure the marking on the wall is centered in the notch 1/4” IMPORTANT! Be sure to leave a ~1/4”gap when tightening screws to leave room for adjustment when the outer bands (B) are installed.
Page 17
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Use waterlevel Make sure the marking on th wall is centered in the notch 1/4” 4x H IMPORTANT! Be sure to leave a 1/4”gap when tightening screws to leave room for adjustment when the outer bands (B) are installed.
Page 18
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) DET 3 Remove from their temporary positions Use rubber mallet! IMPORTANT! Leave space IMPORTANT! Be sure to leave a 1/4”gap when tightening screws to leave room for adjustment when the outer bands (B) are installed.
Page 19
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Use the appropriate length screws to fasten the halves together as shown in the diagram. Raise slightly before installing the combined board. Use rubber mallet! Join two boards together (as shown in diagram II) that will bridge the width of the "A"...
Page 20
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) 2x DET 6 IMPORTANT NOTE: DO NOT over tighten. Tighten so straps lay flat with no bends. Remove Bolts shall not bend Strap Place the bands around the barrel on the outer side of the cradle 10A.
Page 21
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Remove all temporary braces Remove all temporary braces 1x DET G 6x K Upper vent 3x DET F 6x K Lower vent 10B. All drawing are for illustrative purposes only...
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) INTERIOR Attention! Leave 5/8” gap. 31 1/8” End View 2x DET 10a 1 3/8” Attention! Leave gap.1 3/8” 6x H 6x H from glass-wall DET 10c Pre-drill holes 5/32" Install 2pc of in the middle of the saunaroom...
Page 23
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) ATTENTION! Heater Guard May Not Meet The Safety Distances Of All Heaters And Should Not Be Used If The Heater Does Not Fit! Don’t over tighten DET 10/2 2x M Fasten the opposite 4x H sides in the same way!
Page 24
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) Pre-drill holes 5/32" Pre-drill holes 5/32" 1x DET 12/2 1x DET 12/1 2x H 2x H Pre-drill holes 5/32" Pre-drill holes 5/32" 2x M 2x M Pre-drill holes 5/32" Pre-drill holes 5/32"...
Page 25
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) ATTENTION Refer to shingle installation manual provided in package. 1x DET 14 Use waterlevel 4x H Pre-drill holes 5/32" Pre-drill holes 5/32" 2x DET 11 6x H All drawing are for illustrative purposes only...
Page 26
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) ATTENTION Heater Guard May Not Meet The Safety Distances of All Heaters and Should Only be used with the supplied MrSteam heater 2x DET 15a Pre-drill holes 5/32" 2x J Pre-drill holes 1/8"...
Installation, Operation & Maintenance Manual LOCATING THE CONTROL DO NOT install the control on the outside of outdoor steam rooms 1. For outdoor rooms the control must be installed inside the sauna room. 2. Mount the control on a vertical wall. 3.
Page 28
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) 2x M ATTENTION 1x DET 21 1.1” The door must open outwards. If you need the door handle to be on the Use waterlevel opposite side, rotate door 2x DET 21c 180 degrees.
Page 29
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) ATTENTION Refer to shingle installation manual provided in package. 5x H 46 1/2” 5x H 2x DET 22 DET N End View End View 3/8” 3/8” All drawing are for illustrative purposes only...
Page 30
Installation, Operation & Maintenance Manual RMSBS78A (79” Depth x 89” Diameter) ATTENTION Refer to shingle installation manual provided in package. Shingles overlap to top DET O Cut and use Refract DET N into 3 pieces on other end DET N 9x DET 25 9x DET 25 18x H...
Sauna by MrSteam Installation & Service Instructions Electric Shock Hazard - High voltage exists within this equipment.There are no user serviceable parts in this equipment. All installation and service to this equipment should be performed by qualified licensed personnel in accordance with local and national codes.
Sauna by MrSteam Installation & Service Instructions Section 2: Securing Heater to the Wall Do not use the sauna room or heater for drying clothes, bathing The Mr. Sauna heater must mounted on a flat wall, as shown in the room instructions.The suits, etc.
Page 36
Sauna by MrSteam Installation & Service Instructions Heater Model Height From Floor “A” To ensure safe operation, ensure the mounting bracket is level and SCA04A ” secured to the wall using the 6 screws provided. SCA06A ” SCA09A ” Secure the Mounting Bracket to the Wall Using the 6...
Page 37
Sauna by MrSteam Installation & Service Instructions 8. Remove the heat shield from the heater and secure it in place using the 3 screws provided. All drawing are for illustrative purposes only...
Sauna by MrSteam Installation & Service Instructions Section 3: Electrical Wiring All wiring must be accomplished by a licensed electrical contractor. Refer to the Heater Specification Chart to determine the wire size and circuit protection required.The complete sauna consisting of heater and temp/time control should be properly grounded according to NEC requirements.
Sauna by MrSteam Installation & Service Instructions Section 4: Sauna Rocks Installing the Rocks Use only with rocks supplied with 1. Verify that the heater is securely the heater. The Sauna heater must not be operated mounted to the wall according to unless the rock compartment in the top of instructions.
Sauna by MrSteam Installation & Service Instructions Section 5: Maintenance and Cleaning Saunas expose the users to elevated temperatures. If used improperly or by The sauna heater should be cleaned occasionally with a damp cloth. Never use any solvents or bleaches. The rocks should be removed once a inappropriate persons, exposure to heat can be year for cleaning.
Sauna by MrSteam Installation & Service Instructions Control Unit To prevent damage to the control unit or an inoperable condition: • Do not mount control unit inside the sauna room • The control unit is protected against water splashed, however it should not come into direct contact with water •...
Sauna by MrSteam Installation & Service Instructions Section 9: Using the Sauna 1. Turn on power to the sauna at the breaker. 2. Turn on power to the control unit by putting the control unit switch into the Temperature Units I positions.
Sauna by MrSteam Installation & Service Instructions Trouble Shooting If an error occurs, the heater will turn off and the control will display an error message while beeping. Error Code Problem Solution Temperature Sensor is not recognized Ensure the temperature probe is installed and connected correctly Check the wire between the control and the control unit is not Temperature sensor short circuit damaged...
Need help?
Do you have a question about the mr.steam RMSBS78A and is the answer not in the manual?