WARNING: CONSULT MANUAL or made unsafe and that there is no risk to persons or property. 1.1.4 The standard builds of all CompAir products are not intended for use in either explosive or WARNING: RISK OF HIGH potentially explosive atmospheres as defined PRESSURE in Directive 94/9/EC.
1 Safety CompAir A shut-off valve must be fitted in the delivery General Safety Precautions air line to enable the compressor unit to be If using compressed air for cleaning purposes, isolated. This is particularly important if more ensure safety regulations are complied with...
Check that the dc link capacitors have Use only lubricating oils and greases fully discharged before starting work on approved by CompAir. Make sure that the the compressor. selected lubricants comply with all relevant safety regulations, especially with regard to...
1 Safety CompAir Always clean up oil spills from both the inside and Precautions must be taken when using acids, outside of the compressor unit before and after alkalis and chemical detergents for cleaning maintenance work. machine parts and components. These materials...
Control System 2 CompAir Control System Controller 2.1.2 A gate drive board isolates the microelectronics in the control unit from the 2.1.1 The microprocessor based compressor power electronic circuits and provides controller and the SR Drive® controller are monitoring and protection for the four...
2 Control System CompAir Earlier Models - 345SR & 475SR CONTROL PANEL MENUS ENTRY MENU SUB MENUS Main Selection Menu Fault History Recall Operational Settings Commissioning - Config Operational settings Scroll up/down last 15 Control mode option Language English faults stored in...
Control System 2 CompAir Later Models - L45SR, L75SR & L120SR CONTROL PANEL MENUS ENTRY MENU SUB MENUS Main Selection Menu Fault History Recall Operational Settings Commissioning - Config Operational settings Scroll up/down last 15 Control mode option Language English...
2 Control System CompAir 2.4.5 Access Code Details Default Settings - General • Customer Code: 2.4.1 Default settings for a number of the operational settings are stored in the SERVICE, HOURS, SERVICE, HOURS. controller. These are suitable for operating the •...
Control System 2 CompAir Default Settings - 345SR, 475SR models Setting Unit Minimum Maximum Step Default Value *P1 for AUTO mode 5·1 13·4 0·1 7·4 *P2 for AUTO mode 5·0 13·0 0·1 7·0 P1 for AUTO mode 5·1 13·4 0·1 7·4...
2 Control System CompAir Default Settings - L45SR, L75SR, L120SR models. Setting Unit Minimum Maximum Step Default Value P1 for AUTO mode 5·1 13·4 (11.9)* 0·1 7·4 P2 for AUTO mode 5·0 13·0 (11.5)* 0·1 7·0 *P1 for AUTO mode 5·1...
Control System 2 CompAir of the set voltage or the phase order is Models L45SR, L75SR and L120SR reversed. The phase monitor will Fitted With Controller No. automatically reset within 500rns when correct C20606-280 conditions are restored. 2.7.1 This controller is fitted to LI20SR compressors 2.8.2...
Page 16
2 Control System CompAir the 'Power fail/supply fault' indicated. This is machine is 'Running'), Trip or Alarm Type 3 ( the standard machine action. active when the machine is Offload and Onload) and Start Inhibit. Overcurrent repeated reset lockout Output status conditions available are...
Page 17
Control System 2 CompAir Normal Display. This ensures that the code is cancelled. If there is no key activity for 60sec, the display returns to Normal Display. The speed display bar graph still shows load relative to normal full load speed i.e. L45SR limited to 3000rpm will show max 60%.
Pressure Range Select Note: Any work on the electrical system This is available on input X01/6 only and is the should be carried out by CompAir or by a default function for this input. trained and certified Distributor. Connecting to the pressure range select input...
Page 19
Electrical System 3 CompAir (separate menu item) for the remote start therefore, that some functions (e. g. Group function to operate. With Remote Start Trip) are energised for healthy and the relay enabled, the keypad start button is disabled will present a closed contact for OK.
Page 20
3 Electrical System CompAir outputs - see following diagrams for The on load output will energise when the connection information. compressor is on load. 3.1.4 Configurable Output Functions Low Temperature Alarm Group Fault A Low Temperature Alarm output will energise when the Low Temperature Alarm is active.
Page 21
Electrical System 3 CompAir Fig. 3.1 - Electrical Connection Diagram - 345SR, L45SR (1 of 3) DL0062AA...
Page 22
3 Electrical System CompAir Fig. 3.2 - Electrical Connection Diagram - 345SR, L45SR (2 of 3) DL0062AA...
Page 23
Electrical System 3 CompAir Fig. 3.3 - Electrical Connection Diagram - 345SR, L45SR (3 of 3) DL0062AA...
Page 24
3 Electrical System CompAir Fig. 3. 4 - Electrical Connection Diagram - 475SR, L75SR (1 of 3) DL0062AA...
Page 25
Electrical System 3 CompAir Fig. 3.5 - Electrical Connection Diagram - 475SR, L75SR (2 of 3) DL0062AA...
Page 26
3 Electrical System CompAir Fig. 3.6 - Electrical Connection Diagram - 475SR, L75SR (3 of 3) DL0062AA...
Page 27
Electrical System 3 CompAir Fig. 3.7 - Electrical Connection Diagram - L45SR (1 OF 3) With Phase Failure Relay DL0062AA...
Page 28
3 Electrical System CompAir Fig. 3.8 - Electrical Connection Diagram - L45SR (2 OF 3) With Phase Failure Relay DL0062AA...
Page 29
Electrical System 3 CompAir Fig. 3.9 - Electrical Connection Diagram - L45SR (3 OF 3) With Phase Failure Relay DL0062AA...
Page 30
3 Electrical System CompAir Fig. 3.10 - Electrical Connection Diagram - L75SR (1 of 3) With Phase Failure Relay DL0062AA...
Page 31
Electrical System 3 CompAir Fig. 3.11 - Electrical Connection Diagram - L75SR (2 of 3) With Phase Failure Relay DL0062AA...
Page 32
3 Electrical System CompAir Fig. 3.12 - Electrical Connection Diagram - L75SR (3 of 3) With Phase Failure Relay DL0062AA...
Page 33
Electrical System 3 CompAir 3.1.8 Fig. 3.13 - Electrical Connection Diagram - L120SR (1 of 4) DL0062AA...
Page 34
3 Electrical System CompAir Fig. 3.14 - Electrical Connection Diagram - L120SR (2 of 4) DL0062AA...
Page 35
Electrical System 3 CompAir Fig. 3.15 - Electrical Connection Diagram - L120SR (3 of 4) DL0062AA...
Page 36
3 Electrical System CompAir Fig. 3.16 - Electrical Connection Diagram - L120SR (4 of 4) DL0062AA...
Page 37
Electrical System 3 CompAir SM1188 Fig. 3.17 - Electrical Connection Diagram - L45SR With Phase Monitoring / Phase Failure PCB - (1 of 4) DL0062AA...
Page 38
3 Electrical System CompAir SM 1189 Fig. 3.18 - Electrical Connection Diagram - L45SR With Phase Monitoring / Phase Failure PCB - (2 of 4) DL0062AA...
Page 39
Electrical System 3 CompAir SM 1190 Fig. 3.19 - Electrical Connection Diagram - L45SR With Phase Monitoring / Phase Failure PCB - (3 of 4) DL0062AA...
Page 40
3 Electrical System CompAir SM 1191 Fig. 3.20 - Electrical Connection Diagram - L45SR With Phase Monitoring / Phase Failure PCB - (4 of 4) DL0062AA...
Page 41
Electrical System 3 CompAir SM 1192 Fig. 3.21 - Electrical Connection Diagram - L75SR With Phase Monitoring / Phase Failure PCB - (1 of 4) DL0062AA...
Page 42
3 Electrical System CompAir SM 1193 Fig. 3.22 - Electrical Connection Diagram - L75SR With Phase Monitoring / Phase Failure PCB - (2 of 4) DL0062AA...
Page 43
Electrical System 3 CompAir SM 1194 Fig. 3.23 - Electrical Connection Diagram - L75SR With Phase Monitoring / Phase Failure PCB - (3 of 4) DL0062AA...
Page 44
3 Electrical System CompAir SM 1195 Fig. 3.24 - Electrical Connection Diagram - L75SR With Phase Monitoring / Phase Failure PCB - (4 of 4) DL0062AA...
Page 45
Electrical System 3 CompAir SM 1196 Fig. 3.25 - Electrical Connection Diagram - L120SR With Phase Monitoring / Phase Failure PCB - (1 of 4) DL0062AA...
Page 46
3 Electrical System CompAir SM 1197 Fig. 3.26 - Electrical Connection Diagram - L120SR With Phase Monitoring / Phase Failure PCB - (2 of 4) DL0062AA...
Page 47
Electrical System 3 CompAir SM 1198 Fig. 3.27 - Electrical Connection Diagram - L120SR With Phase Monitoring / Phase Failure PCB - (3 of 4) DL0062AA...
Page 48
3 Electrical System CompAir 3.1.7 SM 1199 Fig. 3.28 - Electrical Connection Diagram - L120SR With Phase Monitoring / Phase Failure PCB - (4 of 4) DL0062AA...
IGBT Tester IGBT Tester part number 98506-24 can be Test Equipment ordered from CompAir UK Ltd. 4.1.1 To carry out checks on the electrical Slave air supply components and the circuit cards inputs and...
4 Fault Diagnosis CompAir Cage-Clamp Screwless Terminals Power Supplies 4.2.1 The connections on the controller terminal Caution: The high voltage (primary) and blocks are fitted with cage-clamp screwless low voltage (secondary) circuits must NOT terminals. The cage-clamp design ensures be connected in any way (e.g. via test that the clamping force adjusts to sizes of probes, wiring etc.)
Fault Diagnosis 4 CompAir 4.4.1 To check the air filter differential pressure 4.4.2 To check the emergency stop circuit switch The Emergency Stop button has two contacts L45SR and L75SR models which will open if the Emergency Stop button is pressed. One contact is connected to the...
4 Fault Diagnosis CompAir Connect the multimeter between the Sensors disconnected end of the wire and the plug Caution: The high voltage (primary) and terminal. low voltage (secondary) circuits must NOT Apply a calibrated known pressure to the be connected in any way (e.g. via test sensor and measure the dc current in the probes, wiring etc.)
Page 53
Fault Diagnosis 4 CompAir 4.6.2 To check the air/oil temperature sensors Temperature (°C) Sensor Res. (ohms) The temperature sensors are spreading 1605 resistance type thermistors. The resistance of 1678 the thermistors will increase as the applied 1762 temperature increases. The controller...
4 Fault Diagnosis CompAir 4.7.2 Application Control Program IC Controller Instructions for renewing the control program Caution: When working with static IC within a SureScan controller: sensitive components, ie, circuit cards and memory IC’s etc, always take antistatic Remove the controller from the compressor.
Page 55
Fault Diagnosis 4 CompAir Fig. 4.6 - Arrangement of Controller Cards 4.7.3 Motor Drive Program IC 4.7.4 FPGA Data IC Normally it is not necessary to change the A need to change this IC is not anticipated. motor drive program IC. However some...
4 Fault Diagnosis CompAir 4.8.5 DC Link Low Voltage Fault (figs. 4.12, 4.13) SR Fault Location This fault occurs when the DC link voltage is 4.8.1 SR Current Sensor Fault (figs. 4.7 and 4.8) below operating level. The SR drive current sensor circuit has Refer to the flow chart in figs.
Page 57
Fault Diagnosis 4 CompAir 4.8.10 Heatsink Temperature Sensor Fault 4.8.13 SR Power Supply Fault * This fault occurs when the resistance of the There has been an interruption in the power heatsink temperature sensor is outside of it’s supply. working range. Possible causes are: 4.8.14...
Page 58
4 Fault Diagnosis CompAir Fig 4.7 - SR Current Sensor Fault (1 of 2) DL0062AA...
Page 59
Fault Diagnosis 4 CompAir Fig. 4.8 - SR Current Sensor Fault (2 of 2) DL0062AA...
Fault Diagnosis 4 CompAir 4.8.17 LSR phase monitoring / phase failure PCB SR Test Procedures - Safety PCB part no. SR05-00060 replaces the former WARNING “Soft Start Resistor & VDR” PCB. Symptoms: Machines that feature circuit board SR05-00060 have been known to suffer spurious trip conditions, giving erroneous •...
Page 68
4 Fault Diagnosis CompAir Use a digital multimeter equipped with a diode 4.10.2 Fast Diode Module (Common Anode) test function (fig. 4.16). If the forward voltage does not compare with the value shown in figs. 4.17 - 4.19, the device is faulty.
One of the IGBTs is forced open circuit by linking its gate connection to the emitter 4.11.1 Using IGBT tester, CompAir part number enabling the internal fast diode to be tested. 98506-24, connect as shown below. In the illustrations below the two ends of the same On the right hand side of the IGBT there are connecting wire are shown by ‘a’...
Page 70
4 Fault Diagnosis CompAir 4.11.3 Latest Semikron IGBTs Test as in 4.11 and then test with diode tester according to the diagram on the IGBT. Fig. 4.22 - Circuit of IGBT type GAL Fig. 4.23 - Circuit of IGBT type GAR...
4 Fault Diagnosis CompAir Clean residue compound from heatsink with a 4.12 IGBT Removal and Fitting mild degreaser. Ensure that there is no Instructions spillage on to other components. 4.12.1 Removal (L45SR and L75SR) 4.12.4 Refitting (L120SR) Open power converter door and remove all Clean the back of the IGBT’s from any...
Fault Diagnosis 4 CompAir Use the recommended digital multimeter 4.14 Electrolytic Capacitor Test switched to the resistance/capacitance Procedures measuring range ( ). Press the yellow button (1) to select capacitance 4.14.1 Electrolytic Capacitor Test measurements. Caution: All electrical connections and connection bars must be removed from a device before it can be tested.
4 Fault Diagnosis CompAir 4.15.2 L120SR Resistors 4.15 To Check Capacitor Bank Balance Resistors Check the resistor values are within the range shown on the side of the resistors. Disconnect each balance resistor from the capacitor before measuring its resistance. The resistance should compare with the marking on the resistor.
Fault Diagnosis 4 CompAir Remove both laminated bussbars from IGBT’s Measure the insulation resistance between /capacitors including balance resistors and each motor winding phase cable (A1 and B1) snubber capacitors. and earth. Remove both earth wires at the earth bar The resistance reading in each case should from capacitor boxes.
Page 78
4 Fault Diagnosis CompAir 4.17.3 Acceptable ranges for motors L45SR Lmin (mH) Lmax (mH) Lmax/Lmin Ratio 1.30 min 13.00 min > 8.50 1.65 max 18.00 max L75SR Lmin (mH) Lmax (mH) Lmax/Lmin Ratio 0.95 min 9.50 min > 8.50 1.20 max 16.00 max...