Summary of Contents for TAEHA PRO-SPRAY

  • Page 1 PRO-SPRAY System(PRO-SPRAY) User manual Contents...
  • Page 2: Table Of Contents

    How to operate PSC-100 ............................27 5.3.1 Initial screen ................................27 5.3.2 Setting screen ..............................29 5.3.3 DATA SET ................................30 5.3.4 PARA SET ................................33 5.3.5 I / O CHECK ................................34 5.3.6 Ext. SET ..................................35 2/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 3 Doc. Rev. 1.1 PSC-100 Operation switch operation method .....................36 PSC-100 rear part ..............................38 Time Chart ..................................41 Maintenance .................................43 Alarm display and action ............................43 Inspection and measures ............................44 Trouble Shooting ...............................45 3/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 4: Safety Precautions

    Doc. Rev. 1.1 Safety precautions This manual is applied to products manufactured and sold by Taeha Co., Ltd. (here in after referred to as “TAEHA”), so it can not be partially copied without our permission. This manual explains the specifications, installation, wiring, maintenance and inspection, abnormal phenomena and measures of our products.
  • Page 5 Do not apply main power supply other than the voltage specified in this user’s manual. It may cause malfunction. 2. Connect the terminals and wiring correctly. If not, it mayh cause malfunction. 5/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 6 Our equipment includes driving and rotating parts. Please install a safety net on the rotating part and ever approach it during operation. Precautions for maintenance and inspection Caution 6/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 7 Please be sure to shut off the external power completely and check the dispense completely before cleaning. If not, there is a danger of electric shock. Disposal notes Caution Dispose of this equipment as industrial waste. 7/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 8: General Information

    - Following - When changing equipment without permission of Taeha Co., Ltd. 2. If a person other than Taeha’s technical support person fixes the equipment or repairs without using the specified parts 3. If any part other than specification specified by Taeha Co., Ltd. Is used in the product 4.
  • Page 9: Precautions

    4. Do not turn off the power or cut off the air pressure if the equipment is not in danger/caution during operation. Serious problems with the use of the equipment may occur. 5. If a serious error occurs in the equipment, please contact us. 9/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 10: Features Of Pro-Spray

    Doc. Rev. 1.1 Features of PRO-SPRAY PRO-SPRAY System is a Pump system Spray System developed based on our PRO-PUMP. Compared to the existing pneumatically driven Spray Valve, it has the advantage that the discharge rate can be set precisely. You can also use the precision regulator to control the Spray air pressure with high precision.
  • Page 11 1 EA Shot end: 2 Length : 2.0m, Spray Air Hose 1 EA (I.D)∅ 2.5 x (O.D)∅ 4.0 Terminal Block 10 Pin 2 EA Connector for external I/O signal 11/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 12: Specification

    ∅ 0.5 ~ ∅ 0.8 Mixing Method External Mix Type Operating temperature 0 ~ 50℃ (Avoid direct sunlight) Operating humidity 10 ~ 85%RH(without condensation) Internal vibration Less than 0.5G 12/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 13: Appearance And Description

    PRO SPRAY System(PRO-SPRAY) Doc. Rev. 1.1 Appearance and description Figure 2. Appearance of Pro-spray 13/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 14: Nozzle Type

    Custom-made PSP-150/500 29x(L)346X(A)18 27x(L)346X(A)13 29x(L)346X(A)8 29x(L)346X(A)9 * For special order specifications, contact our technical sales manager. (Long nozzle type, etc.) Table 5. Spray shape for each Pro-spray nozzle Nozzle type (Micro Spray) (Wide Spray) (Flat Fan) Nozzle type Spray shape...
  • Page 15: Materials

    AL2011 (Black Anodizing) Lip Seal UHMW PE Chamber AL2011 (ENP) Material contacting part Air Block AL2011 (ENP) SUS303F Air Cap SUS303F Nozzle part Vortex Block AL2011 (ENP) Nozzle SUS303F 15/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 16: Operationof Pro-Spray

    PRO SPRAY System(PRO-SPRAY) Doc. Rev. 1.1 Operationof Pro-spray Figure 3. Names of each part 16/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 17: Pro-Spray(Nc Type) Partlist

    PRO SPRAY System(PRO-SPRAY) Doc. Rev. 1.1 PRO-SPRAY(NC Type) Partlist Figure 4. Pro-spray(NC type) partlist 17/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 18 PSP-500-NC-3 Chamber AL2011 PSP-500-NC-4 Stator ASSY PSP-500-NC-5 Air Block AL2011 PSP-500-NC-6 Nozzle SUS303F PSP-500-NC-7 Vortex Block SUS303F PSP-500-NC-8 Air Cap SUS303F PSP-500-NC-9 SUS303F PSP-500-NC-A O-ring(P16) FKM(1472) PSP-500-NC-B O-ring(SS11) FKM(1472) 18/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 19: Pro-Spray Ms Type Partlist

    PRO SPRAY System(PRO-SPRAY) Doc. Rev. 1.1 4.2 PRO-SPRAY MS Type Partlist Figure 5. Pro-spray(MS type) partlist 19/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 20 Nozzle(MS Type) METAL NEEDLE (19G / 23G) PSP-500-MS-8 Air Cap SUS303F PSP-500-MS-9 SUS303F PSP-500-MS-10 Night Cap AL2011 PSP-500-MS-A O-ring(AS016) FKM(1472) PSP-500-MS-B O-ring(S5) FKM(1472) PSP-500-MS-C O-ring(SS11) FKM(1472) PSP-500-MS-D O-RING(AS016) FKM(1472) 20/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 21: Pro-Spray(Ws Type) Partlist

    PRO SPRAY System(PRO-SPRAY) Doc. Rev. 1.1 4.3 PRO-SPRAY(WS Type) Partlist Figure 6. Pro-spray(WS type) partlist 21/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 22 AL2011 PSP-500-WS-6 Nozzle SUS303F(CERAMIC) PSP-500-WS-7 Air cap SUS303F PSP-500-WS-8 SUS303F PSP-500-WS-9 Night cap AL2011 PSP-500-WS-A O-Ring(SS11) FKM(1472) PSP-500-WS-B O-Ring(P20) FKM(1472) PSP-500-WS-C O-Ring(S5) FKM(1472) PSP-500-WS-D O-Ring(AS016) FKM(1472) PSP-500-WS-E O-Ring(AS016) FKM(1472) 22/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 23: Pro-Spray Ff Type Partlist

    PRO SPRAY System(PRO-SPRAY) Doc. Rev. 1.1 4.4 PRO-SPRAY FF Type Partlist Figure 7. Pro-spray(FF type) partlist 23/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 24 AL2011 PSP-500-FF-6 Nozzle SUS303F(CERAMIC) PSP-500-FF-7 Air cap SUS303F PSP-500-FF-8 SUS303F PSP-500-FF-9 Night cap AL2011 PSP-500-FF-A O-Ring(SS11) FKM(1472) PSP-500-FF-B O-Ring(P20) FKM(1472) PSP-500-FF-C O-Ring(S5) FKM(1472) PSP-500-FF-D O-Ring(AS016) FKM(1472) PSP-500-FF-E O-Ring(AS016) FKM(1472) 24/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 25: Pro-Spray Tm Controller(Psc-100)

    PRO SPRAY System(PRO-SPRAY) Doc. Rev. 1.1 PRO-SPRAY Controller(PSC-100) Appearance Figure 8. Appearance of PSC-100 25/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 26: Specification

    RS232, D_SUB 9 PIN Input Signal NPN or Normal Open Signal Dosing End Signal NPN or Open Collector Temperature 10 ~ 40℃ (Avoid direct sunlight) Humidity 30 ~ 70 %(without condensation) 26/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 27: How To Operate Psc-100

    ✽ Can be set to "AUTO", "TIME", or "STEADY" depending on the control method of Spray. ✽ Displays the Program Number. ✽ Up to 32 can be saved. 27/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 28 ✽ Displays the reverse rotation time of Pump. ✽ Infinite intermittent Spray while the Spray signal is ON in Auto mode Functionally represents the pause time. 28/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 29: Setting Screen

    5.3.2 Setting screen If you select the setting screen at the bottom right of the initial screen, a screen like the one shown below will be displayed, and you can set the usage conditions for PRO-SPRAY. Figure 10. Setting screen DATA SET This menu is for entering the setting values for using PRO-SPRAY.
  • Page 30: Data Set

    5.3.3 DATA SET Figure 11. Data set menu In the DATA SET menu, you can set the operating time of the pump using the discharged air of PRO-SPRAY. By pressing DATA SET, you can set sequentially from SPRAY AIR to AUTO CYCLE.
  • Page 31 ✽ You can set the time within 0.01 to 999.99 sec. ✽ Set the time when Spray Pump and Air are discharged at the same time. ✽ You can set the time within 0.01 to 999.99 sec. 31/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 32 ✽ While the Spray signal is ON, "Spray-> Pause-> Spray-> ..." This item sets the pause time of the infinite intermittent Spray function ✽ You can set the time within 0.01 to 999.99 sec. 32/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 33: Para Set

    Figure 14. Para set You can select the PARA SET menu, select the model of PRO-SPRAY to use, and set the Sensor and emergency button to be input to the controller rear port. Touch PARA SET to set DISPENSER MODEL, EMERGENCY CONTACT, and LEVEL SENSOR CONTACT..
  • Page 34: I / O Check

    Table 15. Details of I/O check Display Description ✽ Select whether to use the stirrer. ✽ Set the stirring speed. ✽ Set the operating time when using the stirrer. 34/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 35: Ext. Set

    Select the Ext.SET menu to decide whether to use the decision to change the channel externally or internally. Table 16. Details of Ext.SET Display Description ✽ Set the decision-making authority for changing channels. OFF: Change channel in controller ON: Change the upper channel via ADD signal 35/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 36: Psc-100 Operation Switch Operation Method

    RPM ➡ START TIME ➡ SPRAY TIME ➡ END TIME ➡ SUCK BACK SPEED ➡ SUCK BACK TIME ➡ AUTO CYCLE(AUTO MODE) ✽ When the setting is completed, press the button to finish the setting. 36/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 37 ✽ TIME MODE : Only run time is sprayed. ✽ STEADY MODE : Only the switch on state is sprayed. ✽ AUTO MODE : Spray ➡ Pause ➡ Spray ➡ Repeat 37/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 38: Psc-100 Rear Part

    ✽ Fuse Holder: Small glass tube 3A (including Spare 1EA) ✽ AC Receptacle: Power Cord insertion slot, AC 100-240V, 50 / 60Hz Free Volt (Be sure to perform Earth processing.) 38/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 39 ✽ COM : (-) Common is required to match the potential difference with the host controller. ✽ +24V(2A) : It is used when it is necessary to use the power supply inside the controller. 39/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 40 ✽ COM : Common is required to match the potential difference with the host controller. ✽ +24V : Use when you need to use the controller's internal power supply. 40/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 41: Time Chart

    PRO SPRAY System(PRO-SPRAY) Doc. Rev. 1.1 Time Chart Figure 19. Time mode Figure 20. Steady mode 41/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 42 PRO SPRAY System(PRO-SPRAY) Doc. Rev. 1.1 Figure 21. Auto cycle mode 42/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 43: Maintenance

    Caution Some alarms cannot be released even after reset. In this case you must reboot (power on / of) after completing action for the relevant error. 43/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 44: Inspection And Measures

    1) Fastening condition of the fixed parts and joints in the equipment Other checks Periodically 2) Joined and tightened condition of wiring 3) Arrangement condition around the equipment 44/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...
  • Page 45: Trouble Shooting

    If an abnormal noise occurs while Check the status of abrasion of the roatry seal in the seal block. the pump is operating Check the condition of the motor reducer. 45/45 2020/11/16 Copyright © 2020 by TAEHA CORP. All Rights Reserved...

This manual is also suitable for:

Psp-015Psp-050Psp-150Psp-500

Table of Contents