Download Print this page

Sentinum FEBRIS Quick Start Manual

Wireless sensor

Advertisement

Quick Links

1
Febris Quick Start Guide EN
FEBRIS QUICK START GUIDE
Please observe the warnings and instructions in the operating
instructions to ensure the safety of you, your surroundings and the
sensor!
ASSEMBLY AND INSTALLATION
Install the sensor on an interior wall at a height of between 1.50m and 1.80m. Ensure that
the LEDs are on the lower right-hand side. Ensure that the sensor is at least 20 cm away
from people and is located in an area below 2000 m above sea level. Use either magnets
or suitable screws for mounting. The detailed steps can be found in the operating
instructions.
COMMISSIONING
1. Open the sensor using the tabs provided (on
the bottom edge in the picture). If necessary,
carefully use a blunt object.
Sentinum GmbH | Heinrich-Stranka-Str. 3-5 | 90765 Fürth | DE – Changes Reserved – 25.03.2025
Febris is a smart, wireless sensor series from
Sentinum for monitoring indoor air quality and
ambient conditions. Depending on the model, it
measures CO₂, temperature, humidity, air
pressure or surface temperatures. LEDs and a
buzzer warn if limit values are exceeded. The
data is transmitted energy-efficiently via MIOTY®,
NB-IoT or LoRaWAN®. A double tap triggers an
instant measurement. Powered by 4x AA
batteries, easily replaceable. Wall mounting
recommended, but can also be placed on tables
or cabinets.
info@sentinum.de
|
www.sentinum.de

Advertisement

loading
Need help?

Need help?

Do you have a question about the FEBRIS and is the answer not in the manual?

Questions and answers

Summary of Contents for Sentinum FEBRIS

  • Page 1 COMMISSIONING 1. Open the sensor using the tabs provided (on the bottom edge in the picture). If necessary, carefully use a blunt object. Sentinum GmbH | Heinrich-Stranka-Str. 3-5 | 90765 Fürth | DE – Changes Reserved – 25.03.2025 info@sentinum.de www.sentinum.de...
  • Page 2 4. Mount the back as a wall bracket at the desired location using magnets, screws or adhesive strips. You will find a detailed description of the mounting options and procedure in the operating instructions under 5. Sentinum GmbH | Heinrich-Stranka-Str. 3-5 | 90765 Fürth | DE – Changes Reserved – 25.03.2025 info@sentinum.de www.sentinum.de...
  • Page 3 Tilt the sensor backwards so that it snaps securely into the bracket and the snap lock. Ensure that the sensor is fully seated in the bracket and is firmly attached. Sentinum GmbH | Heinrich-Stranka-Str. 3-5 | 90765 Fürth | DE – Changes Reserved – 25.03.2025 info@sentinum.de www.sentinum.de...
  • Page 4 = ((bytes[5] << 8) | bytes[6]) / 100; decoded.networkBaseType = 'lorawan'; decoded.networkSubType = 'tti'; it = 7; if(decoded.minor_version >= 3){ it = 7; //Luftfeuchte ist bei allen Varianten enthalten Sentinum GmbH | Heinrich-Stranka-Str. 3-5 | 90765 Fürth | DE – Changes Reserved – 25.03.2025 info@sentinum.de www.sentinum.de...
  • Page 5 //Taupunkt seit minor version 2 bei alle Varianten enthalten (ausnahme früher versionen subversion 2, daher byte prüfen) (decoded.minor_version >= && bytes[it] ) { decoded.dew_point = bytes[it++] - 100; Sentinum GmbH | Heinrich-Stranka-Str. 3-5 | 90765 Fürth | DE – Changes Reserved – 25.03.2025 info@sentinum.de www.sentinum.de...
  • Page 6 (decoded.product_version & 0x04) { decoded.wall_temperature = bytes[it++] - 100; decoded.therm_temperature = bytes[it++] - 100; decoded.wall_humidity = bytes[it++]; return data: decoded, warnings: [], errors: [] Sentinum GmbH | Heinrich-Stranka-Str. 3-5 | 90765 Fürth | DE – Changes Reserved – 25.03.2025 info@sentinum.de www.sentinum.de...