Advertisement

Quick Links

Instructions for Use
C6 X1 WEB
HMI Series
Translation of the original manual
Document 20374837 EN 01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HMI Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KEB HMI Series

  • Page 1 Instructions for Use C6 X1 WEB HMI Series Translation of the original manual Document 20374837 EN 01...
  • Page 2 Imprint KEB Automation KG Suedstraße 38, D-32683 Barntrup Germany Tel: +49 5263 401-0 • Fax: +49 5263 401-116 E-Mail: info@keb.de • URL: https://www.keb-automation.com ma_ca_c6-x1a-inst-20374837_en Version 01 • Edition 10/09/2024...
  • Page 3: Table Of Contents

    Table of contents Table of contents Introduction ..............................Markings..............................1.1.1 Warnings..........................1.1.2 Information notes ........................1.1.3 Symbols and markers ......................Laws and guidelines..........................Warranty and liability..........................Support..............................Copyright............................... Validity of this manual ........................... Target group............................General Safety Instructions.......................... Installation ............................. Product description ............................
  • Page 4: List Of Figures

    List of figures KEB Automation KG List of figures Fig. 1 Nameplate X1A ............................Fig. 2 Dimensions ............................Fig. 3 Rear view ............................... Fig. 4 Monitor mounting ........................... Fig. 5 Ethernet port assignment ........................ma_ca_c6-x1a-inst-20374837_en...
  • Page 5: List Of Tables

    List of tables List of tables ma_ca_c6-x1a-inst-20374837_en...
  • Page 6: Introduction

    1 | Introduction KEB Automation KG 1 Introduction The described devices, accessories, hardware and/or software are products of KEB Automation KG. The enclosed documents correspond to conditions valid at printing. Misprint, mistakes and technical changes reserved. 1.1 Markings 1.1.1 Warnings Certain operations can cause hazards during the installation, operation or there- after.
  • Page 7: Symbols And Markers

    This also applies to any violation of industrial property rights of a third- party. Selection of KEB units in view of their suitability for the intended use must be done by the user. Tests can only be carried out within the scope of the intended end use of the product (Application) by the Customer.
  • Page 8: Validity Of This Manual

    1 | Introduction KEB Automation KG This KEB product or parts thereof may contain foreign software, incl. free and/or open source software. If applicable, the license terms of this software are con- tained in the instructions for use. The instructions for use are already available, can be downloaded from the KEB website or can be requested from the respective KEB contact person.
  • Page 9: General Safety Instructions | 2

    General Safety Instructions | 2 2 General Safety Instructions The products are designed and constructed in accordance with state-of-the-art technology and the recognised safety rules and regulations. However, the use of such devices may cause functional hazards for life and limb of the user or third parties, or damages to the system and other material property.
  • Page 10: Product Description

    3 | Product description KEB Automation KG 3 Product description The following devices are described in this manual: Model Mat.No. Description C6 X1-07 A7C6XA1-1100 Web HMI 7” TFT, 1024x600, PCAP Touch, 8GB Flash memory, PoE Ethernet, Wi- Fi, NFC, Web Browser...
  • Page 11: Product Identification

    ⑤ Year/week of manufacture ⑥ IEEE standard and performance ⑦ Ambient temperature ⑧ Additional logos ⑨ Manufacturer address ⑩ QR code with KEB link ⑪ Manufacturer logo ⑫ Barcode with serial number ⑬ Data matrix code for internal use ⑭ CE label ⑮...
  • Page 12: Technical Data

    4 | Technical data KEB Automation KG 4 Technical data 4.1 Operating conditions 4.1.1 Climatic ambient conditions Storage Standard Value Notes Ambient temperature EN 60068-2-1 -30…80 °C 7“ and 10“ EN 60068-2-2 -20…70 °C 15“ and 21“ EN 60068-2-14 Relative humidity EN 60068-2-30 5…85 % without condensation...
  • Page 13: Other Data

    Technical data | 4 Surge EN 61000-4-5 ±0.5 kV DC input (line to earth) ±0.5 kV DC input (line to line) ±1 kV Signal cable (against earth) Conducted immunity, induced by EN 61000-4-6 10 V 0.15…80 MHz high-frequency fields Mains frequency magnetic field EN 61000-4-8 30 A/m 50/60 Hz against housing 4.2 Other data Backup battery...
  • Page 14: Product Data

    4 | Technical data KEB Automation KG • Electrode gel/paste • Hydrogen peroxide (3% solution) • NaCl (0.9% solution) • Coffee • Dextrose (5% glucose solution) • Hydrogen chloride (0.5% solution PH=1) • Isopropyl alcohol • Sodium hypochlorite • Ethyl alcohol (70%-90%) •...
  • Page 15: Dimensions

    Technical data | 4 4.5 Dimensions Fig. 2: Dimensions Type C6 X1-07 131.6 mm/5.18” 195.2 mm/7.68” 16.5 mm/0.64” 17 mm/0.66” C6 X1-10 183.1 mm/7.20” 264.5 mm/10.41” 16.5 mm/0.64” 17 mm/0.66” C6 X1-15 248 mm/9.76” 398.6 mm/15.69” 26.5 mm/1.04” 17 mm/0.66” C6 X1-21 325.6 mm/12.81” 534.1 mm/21.02” 26.5 mm/1.04” 17 mm/0.66” ma_ca_c6-x1a-inst-20374837_en...
  • Page 16: Fig. 3 Rear View

    4 | Technical data KEB Automation KG M5x5 ø22 Fig. 3: Rear view ma_ca_c6-x1a-inst-20374837_en...
  • Page 17: Assembly | 5

    Assembly | 5 5 Assembly Before installation, observe the following notes on the installation location: Avoid locations exposed to direct sunlight for long periods of time (overheating of the device). The device is not intended for installation in contact with corrosive chemical compounds. Check whether the used bracket is suitable for the intended installation location.
  • Page 18: Connection

    6 | Connection KEB Automation KG 6 Connection 6.1 Ethernet/USB port LED1 LED2 Fig. 5: Ethernet port assignment 1 TX+ 2 TX- 3 RX+ 4 not assigned 5 not assigned 6 RX- 7 not assigned 8 not assigned red: off (no connection) on (connec-...
  • Page 19 Connection | 6 • Earth the device via the shielding. Alternatively, the earth connection can be estab- lished via the screws near the plug. ma_ca_c6-x1a-inst-20374837_en...
  • Page 20: Maintenance

    7 | Maintenance KEB Automation KG 7 Maintenance The following maintenance work has to be carried out as required, but at least once a year, by authorised and trained personnel. • Switch off the device before cleaning. • Check device for loose screws and plugs and if necessary tighten up.
  • Page 21: Disposal | 8

    14.08.2018. In principle, these devices may not be left at public or communal recycling or collection points. Unless otherwise agreed between the customer and KEB or unless there is a de- viating mandatory legal regulation, KEB products labelled in this way can be re- turned.
  • Page 22: Certification

    9 | Certification KEB Automation KG 9 Certification 9.1 EU Declaration of Conformity see also 2 EU Declaration of Conformity C6 WEB HMI [} 23] ma_ca_c6-x1a-inst-20374837_en...
  • Page 23 Germany Product type: Part no. xyC6XAz-zzzz KEB C6 X1 Control x = letters A, B, C y = numbers 0 bis 9 z = any letter or number The above given product is in accordance with the following directives of the European Union...
  • Page 24 / 12.2023 Product type: Part no. xyC6XAz-zzzz KEB C6 X1 Control x = letters A, B, C y = numbers 0 bis 9 z = any letter or number The above given product is in accordance with the following directives of the European Union The conformity of the above given product to the European Directive 2014/53/EU is given by complete approval / testing to the following European harmonized standards.
  • Page 25 / 12.2023 Product type: Part no. xyC6XAz-zzzz KEB C6 X1 Control x = letters A, B, C y = numbers 0 bis 9 z = any letter or number European Directive 2011/65/EU with changes of 2015/863/EU (for restrictions of the use for certain hazardous substances in electrical and electronic equipment) is given by qualification of components and manufacturing process within the ISO 9001 QM system.
  • Page 26: Revision History

    10 | Revision history KEB Automation KG 10 Revision history Edition Version Note 2023-12 Pre-series 2024-05 Series version ma_ca_c6-x1a-inst-20374837_en...
  • Page 27: Glossary

    Glossary Glossary Application EN 60068-2-6 The application is the intended use of the KEB Environmental influences - Part 2-6: Test method - product. Test Fc: Oscillation (sinusoidal). German version VDE 0468-2-6. COMBIVERT EN 60529 Proper name for a KEB Drive Controller.
  • Page 28 Glossary KEB Automation KG Human-Machine-Interface describes a visual user interface (touchscreen). PELV Safe protective extra-low voltage (earthed). SELV Safe extra-low voltage (unearthed). ma_ca_c6-x1a-inst-20374837_en...
  • Page 29: Index

    Index Index maintenance work  20 Packaging  21 Return point  21 ma_ca_c6-x1a-inst-20374837_en...
  • Page 30 KEB Automation KG Notes ma_ca_c6-x1a-inst-20374837_en...
  • Page 31 MORE KEB PARTNERS WORLDWIDE: www.keb-automation.com/contact...
  • Page 32 Automation with Drive www.keb-automation.com KEB Automation KG • Suedstraße 38 • D-32683 Barntrup • Tel: +49 5263 401-0 • E-Mail: info@keb.de...

Table of Contents