Summary of Contents for Copeland CHP-T020X-PPC-D61
Page 1
INSTRUCTION GUIDE User manual Air to water heat pump IMPORTANT NOTE: Model: CHP-T020X-PPC-D61 Thank you very much for purchasing our product. Before using your unit, please read this manual carefully and keep it for future reference.
Safety precautions Electrical shock hazard • Failure to follow these warnings could result in serious personal injury. • Disconnect and lock out power to Heat Pump before servicing. • Discharge all capacitors before servicing. • Use Heat Pump with grounded system only. •...
Operation cost of domestic heat pump water heaters is up to 70% saving, saving your expenses in energy costs each year. Copeland heat pumps are not only highly effcient, but also easy and safe to operate, using R410A refrigerant which is environmental-friendly and energy effcient.
Installation of unit The following general shows how to Install the ATW Heat Pump. Materials needed for installation 1. Plumbing fttings. 2. Level surface for proper drainage. 3. Ensure that a suitable electrical supply line with proper electrical wiring is provided. See the rating plate on the heat pump for electrical specifcations and take a note of the specifed current rating.
Installation of unit 6. Even though the controller is waterproof, care should be taken to avoid direct sunlight and high temperature. In addition, the heat pump should be placed to ensure quality viewing of the controller. 7. The plumbing pipes must be installed with proper support to prevent possible damage due to vibration 8.
The storage tank confguration must meet the following criteria: 1. The unit must not be connected directly to a gas or electric heater. 2. If the unit is connected to an old storage tank, the tank should be thoroughly cleaned of scale and sediment before it is installed.
Electrical information Voltage rating , 230V,(50 HZ) Ø Voltage range 195V — 260V(+/-5V) Cable size Max current Cable Remarks (mm2) allowed (A) Power supply cable 3 cable Select the correct cable type and size according to the country or regions regulations. Max.
Page 9
Operation manual Heat Mode: Setting water temperature range is : 30°C ~ 60°C Cool Mode: This unit will not work in cool mode. Do not operate as function is not enabled for user. Defrost: Indication of “df” blink during defrost cycle. When the outdoor temperature drops so low that thick frost accumulates on the condenser coil, the heat pump initiates a defrost cycle, temporarily shifting to cooling mode to warm up the outdoor coil and thaw frost buildup.
Page 10
Error codes with description Codes Error description Only for 5 sec while changing to cool mode Only for 5 sec while changing to heat mode In standby (off) condition Ambient temp. Sensor error Inlet water temp. Sensor error Outlet water temp. Sensor error Tank water temp.
Troubleshoot guide Sr. No. Error codes Possible causes Corrective actions Ambient temperature sensor damaged Inlet water temperature sensor damaged Outlet water temperature sensor damaged Contact dealer regarding replace of Tank water temperature sensor damaged respective sensors Discharge temperature sensor damaged Condenser outlet temperature sensor damaged Coil temperature sensor damaged Compressor discharge temperature sensor faulty...
Page 12
The contents of this publication are presented for informational purposes only and they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. Copeland reserves the right to modify the designs or specifcations of such products at any time without notice.