Pureline PL2801KM Owner's Manual

Swimming pool and spa pump

Advertisement

OWNER'S MANUAL
Swimming Pool and Spa Pump
READ THIS MANUAL CAREFULLY
Notice:
The California Energy Commission requires all pumps purchased for sale or use in a residential pool for filtration in
California be listed on their CEC website.
Important Notice: This manual contains important information about the installation, operation and safe use of
this product. This information should be given to the owner and/or operator of this equipment.
WARNING: This product must be installed and serviced by a qualified pool professional, and must conform to all
national, state, and local codes.
WARNING: Before installing this product, read and follow all warning notices and instructions which are included.
Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call +1
(407) 834-2200 for additional copies of these instructions.
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment,
basic safety precautions should always be followed,
including the following:
READ AND FOLLOW ALL
1.
INSTRUCTIONS.
2. WARNING - To reduce the risk of injury, do not
permit children to use this product unless they are
closely supervised at all times.
3. WARNING - Risk of Electrical Shock. Connect only
to a branch circuit protected by a ground-fault circuit
interrupter (GFCI). Contact a qualified electrician if you
cannot verify that a circuit is protected by a GFCI.
4. WARNING - To reduce the risk of electric shock,
replace any damaged cord immediately.
5. DO NOT install within an outer enclosure or beneath
the skirt of a hot tub or spa.
6. CAUTION - This pump is for use with permanently-
installed pools and may also be used with hot tubs and
spas if so marked. Do not use with storable pools. A
permanently-installed pool is constructed in or on the
ground or in a building such that it cannot be readily
disassembled for storage. A storable pool is constructed
so that it is capable of being readily disassembled for
storage and reassembled to its original integrity.
BEFORE USING THE PUMP
7. The unit must be connected only to a supply circuit
that is protected by a ground-fault circuit-interrupter
(GFCI). Such a GFCI should be provided by the installer
and should be tested on a routine basis. To test the
GFCI, push the test button. The GFCI should interrupt
power. Push the reset button. Power should be
restored. If the GFCI fails to operate in this manner,
the GFCI is defective. If the GFCI interrupts power to
the pump without the test button being pushed, a
ground current is flowing, indicating the possibility of
an electric shock. Do not use this pump. Disconnect the
pump and have the problem corrected by a qualified
service representative before using.
8. TO REDUCE RISK OF ELECTRICAL SHOCK, A copper
bonding connector (8 AWG U.S., 6 AWG Canada) is
provided for bonding the motor to all metal parts of
the swimming pool, spa, or hot tub structure and to all
electrical equipment, metal conduit, and metal piping
within 5 feet of the inside walls of a swimming pool,
spa, or hot tub, when the motor is installed within 5
feet of the inside walls of the swimming pool, spa, or
hot tub.
NOTE: To installer and/or operator of the Swimming
Pool Pump; the manufacturer's warranty will be voided
if the pump is improperly installed and/or operated.
SAVE THESE
9.
INSTRUCTIONS!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PL2801KM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pureline PL2801KM

  • Page 1 OWNER’S MANUAL Swimming Pool and Spa Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Notice: The California Energy Commission requires all pumps purchased for sale or use in a residential pool for filtration in California be listed on their CEC website. Important Notice: This manual contains important information about the installation, operation and safe use of this product.
  • Page 2 Product Contains: CR2032, nominal voltage 3 volts. Call a local poison control center for treatment information WARNING INGESTION HAZARD: This product contains a button cell or coin battery. SAVE THESE INSTRUCTIONS! 2999999415PL - Rev. 0325 - PureLine 48fr.
  • Page 3: Section 1 Installation Information

    filters around the pump. Allow plenty of space above the pump to remove lid and basket for cleaning. drain plug pump may be bolted to level foundation or mounting bracket 2999999415PL - Rev. 0325 - PureLine 48fr.
  • Page 4 407-834-2200. contaminants, reinstall all conduit and terminal box covers. Do not force connections into the conduit box. 4. Connect L1, L2/N, and Ground to the terminal block as shown on the motor nameplate. 2999999415PL - Rev. 0325 - PureLine 48fr.
  • Page 5: Section 2 Equipment Operation, Service, And Maintenance

    WARNING: Before servicing the pump, switch off the outside the U.S. dial +1 407-834-2200. circuit breakers at the power source. Severe personal injury or death may occur if the pump starts while your hand is inside the pump. 2999999415PL - Rev. 0325 - PureLine 48fr.
  • Page 6 4. Pull the motor and flange/seal housing out from the pump casing/strainer tank. Remove the pump casing o-ring. The impeller is connected to the motor shaft. 2999999415PL - Rev. 0325 - PureLine 48fr.
  • Page 7: Section 3 Troubleshooting Guide

    Back wash filter when filter pressure is high, or clean cartridges. b. No skimmer basket. Clean skimmer and pump strainer basket. c. Closed valves or blocked lines. See problem 1. d. Suction air leak. See problem 1. 2999999415PL - Rev. 0325 - PureLine 48fr.
  • Page 8 Heaters should be one size larger than full load amps device. shown on motor nameplate. d. Overload due to binding in pump Indicated by high amperage readings on motor, or wrong size impeller. binding shaft. Disassemble unit and correct. 2999999415PL - Rev. 0325 - PureLine 48fr.
  • Page 9: Section 4 Replacement Parts And Exploded View

    O-ring - Casing 190 x 5mm 2991400035 554.1 Washer - Flat 3/8” SS 2901516102 Flange/Seal Housing 2991000155 920.1 Nut - 3/8-16 Brass 2500300937 1.5” Union Package CPL 2920359501 Rubber Buffer - 10 x 10 x 27mm 2999999415PL - Rev. 0325 - PureLine 48fr.
  • Page 10: Section 5 Servicing Information

    Buyer’s operation and maintenance of the pump and motor in strict accordance with the manufacturer’s printed operator/maintenance manuals delivered with the pump and motor. 2999999415PL - Rev. 0325 - PureLine 48fr.
  • Page 11 (M-F) 9:00 am - 6:00 pm EST Phone: 407-834-2200 Date of Installation: ____________________________________________ Installed by: ____________________________________________ Serial Number: ____________________________________________ For Service Call: ____________________________________________ © 2025 All Rights Reserved. This document is subject to change without notice. DF.1000.JP 2999999415PL - Rev. 0325 - PureLine 48fr.
  • Page 12 2999999415PL - Rev. 0325 - PureLine 48fr.

This manual is also suitable for:

Easyfit pl2805spEasyfit pl2806wfEasyfit pl2807wf

Table of Contents