  • Page 1 ALIA SMART TOILET USER & INSTALLATION MANUAL ALIA Global Pty Ltd 47b Cooper St, Campbellfield 3061 Melbourne, Australia sales@aliaglobal.com.au www.aliaglobal.com.au +61 (03) 9219 0189...
  • Page 2 Water inlet NTC Fault removal Water stop heating indicator flashes and open circuit or after Inlet NTC the buzzer sounds and cleaning stop AG-ST10003B short circuit NTC recovery for 3 seconds Fault removal The water temperature Inlet water after Water stop heating...
  • Page 3 Before installation, please read this manual carefully and install it in strict accordance with the instructions. After reading, please put this manual in a prominent position. Keep the place properly. In order to avoid Product part Phenomenon Cause Solutions injury and property damage to users and others, please strictly observe the safety warnings and precautions. or function Whether the power supply is off Power on...
  • Page 4 WARNING 3. After loosening the tape, pull out the 4. Connect and tighten the four removed activated carbon, replace it with a water pipes in turn. Put the cover back new one, and then install the cover into the ceramic body, lock the screw Please pull out the power plug Do not use water other than tap water, and lock it.
  • Page 5 Nozzle maintenance 1. Nozzle extends WARNING Press and hold the "Stop" button and "Rear wash" button on the remote control for 3 seconds at the same time to enter the manual cleaning procedure. Do not connect the water pipe with the Do not place the product where it may outlet pipe of the water heater.
  • Page 6 WARNING 3. When water and electricity are cut off If the supply cord is damaged, it must be Cleaning and user maintenance shall not replaced by the manufacturer, its service 1.Flushing during power outage be made by children without supervision. agent or similarly qualified persons in (under the condition that the spare order to avoid a hazard.
  • Page 7: Parts Diagram

    Parts diagram 1. AUTOMATIC OPEN/CLOSE LID FUNCTION (Applicable for models with this function ) If you buy an electronic toilet with automatic open/close lid function, this product can realize automatic opening/closing of the toilet lid and seat. Warning label 1. Auto Open Power plug When the human body is close to the toilet, the toilet lid will open automatically after the...
  • Page 8 Hardware Included 4. Remote control match code Before the machine is powered on, press and hold the front wash button on the remote control. The five lights on the remote control will flash and enter the pairing mode. At this time, powering on the machine and press the reset button on the power plug. Waiting until the indicator light of knob flash between red and green alternately, then press the knob.
  • Page 9: Technical Drawing

    Control function setting 1. Nozzle manual cleaning function 426.7 • Press the "Stop" button and "Rear wash" button on the remote control for 3 seconds at the Technical drawing (unit: mm) same time to enter the manual cleaning procedure. Manual cleaning procedure: the nozzle will extend to the longest position and self-clean water flows out continuously.
  • Page 10 Water temperature adjustment When cleaning, the water temperature is adjustable with 6 gears. When in off gear, 5. Install waxing ring into drain outlet; 6. Put the screw through the fixing sleeve the water flows in ambient temperature and the indicator light is off. Install ceramic toilet on corresponding and then install it through the holes(on position according to contour line.
  • Page 11 10. Install the battery box 1. Put battery (9V, not included) in the battery box. 2. Connect the line Stop Short press stop button to cease on-going functions halfway. Battery replacement Full flushing 1. Remove the battery box from the back of the toilet and pull out the battery box connector. Short press this button to perform half flush function.
  • Page 12 Install remote control Install the remote control rack Power/Stop 1. Stick the remote control rack horizontally to 2. Install the expansion pipe into the wall hole, the pre-installation area on the wall, and mark attach the hanger to the wall, align the hole on the 1.