VR07-020 Montage- und Betriebsanleitung Product name DE Installation and operating instructions Product name EN Notice de montage et de mise en service Product name FR Instrucciones de montaje y servicio Product name ES Istruzioni per il montaggio e l’uso Product name IT Montage- en bedrijfsinstructies Product name NL Instrukcja montażu i obsługi...
Page 3
Version. INFL002 v2.0 180511 HDTX806L Flushvalve WC Flushing System V2 with the Fully Automatic Sensor Model: D103/V2/AUTO Dart Valley Systems Tel: +44 (0) 1803 529021 Fax: +44 (0) 1803 559016 www.dartvalley.co.uk Installation and operating instructions HDTX806M VR07-020 - 3 - - 3 -...
Page 4
HDTX806L These instructions relate to the use of the Washroom Control System only, any external or ‘add-on’ parts will be supplied with separate instructions. The electrical part of the installation MUST be carried out by a qualified electrician in accordance with the latest electrical regulations.
Installation EN Installation NL Montage CS Montáž FR Montage PL Montaż FI Asennus ES Montaje SV Montering RU Монтаж IT Montaggio The Control System Box should be located in a dry location and not exposed to dirt, dust or damp. The unit should be accessible when required, but not within easy general reach of unauthorised persons.
Page 6
1. Mains Out By default the channels are programmed for the 2. WC Valve Channel 11 below products. 3. WC Sensor Channel 11 4. WC Valve Channel 12 1. Basin (Tap) Hot 5. WC Sensor Channel 12 2. Basin (Tap) Cold 6.
Page 7
The unit should be securely fixed in a suitable location in a vertical orientation with the glands pointing down, so that the front label can be read correctly. Open lid to expose four fixing holes around the edge of the enclosure. These holes allow the fastening of the unit without removing the printed circuit board.
Page 8
After all external equipment is installed, the mains supply can be connected. When connecting to mains always make sure that the lid is tightly closed and secure. NEVER open the cover with the supply live. When the control unit is first powered on, the power light will illuminate to show that the control box is active. - 8 -...
Page 9
Flushvalve WC Flushing Sy with the Fully Automa Model: D103/V2/AUTO DEFAULT OPTIONAL SETTINGS SETTINGS Typically used with WAVE FLUSH VALVE MENU WC01 - 023 or WC01 - 022 Flush type Single Single or dual WC Flushvalve Flush time(s) 4 seconds 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5 seconds Range Automatic purge OFF, 3, 6, 12, 24, 36, 48, 72 hours...
Page 10
The automatic purge is enabled through the Front Panel Menu. The default setting is disabled. See Menu Settings guide (Step 7) for instructions on how to enable this feature. When the purge feature is enabled each channel (Flushvalve, Hot and Cold Water and Shower) is independently monitored.
Page 11
LUSH VALVE MENU WAVE FLUSH VALVE MENU Flush Type Single Single or Dual Single Single or Dual Single me(s) 4 Seconds Flush Time(s) 4 Seconds 4 Seconds 2, 2.5, 3, 3.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6 & 6.5 Seconds Range c Purge Automatic Purge...
Product disposal EN Installation NL Montage CS Montáž FR Montage PL Montaż FI Asennus ES Montaje SV Montering RU Монтаж IT Montaggio The use of this crossed out wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste.
Product list EN Installation NL Montage CS Montáž FR Montage PL Montaż FI Asennus ES Montaje SV Montering RU Монтаж IT Montaggio The following parts are compatible with the VR07 - 020 Washroom Control System. The actual parts supplied ...
Page 14
AC02-047 - Tactile switch with 50mm stainless steel bezel and Red insert (Hot) AC02-046 - Tactile switch with 50mm stainless steel bezel and Blue insert (Cold) ...
Australia Italy United Kingdom PR Kitchen and KWC Austria GmbH KWC DVS Ltd - Northern Office Water Systems Pty Ltd 6971 Hard, Austria Barlborough S43 4PZ Dandenong South VIC 3175 Numero Verde +39 800 789 233 Phone +44 1246 450 255...
Need help?
Do you have a question about the DVS VR07-020 and is the answer not in the manual?
Questions and answers