  • Page 1 Manuale di installazione Installation manual uso e manutenzione External damper Modular T Smart ATB Compact T D-EIMOC2009-26_01EN Compact T Modular T Smart ABT DATE October 2024 Original instructions Traduzione delle istruzioni originali REPLACES D-EIMOC2009-26_01EN...
  • Page 2: Important Warnings

    Important warnings The pictogram shows a situation of immediate danger or a dangerous situation that might cause injuries or death. The pictogram shows that it is necessary to adopt suitable behaviour in order to avoid jeopardising staff safety and cause damages to the equipment. The pictogram shows particularly important technical information that should be taken into consideration by the people installing or using the equipment.
  • Page 3: Technical Data

    Technical data Duct diameter Size Material name øE [mm] [mm] [mm] [mm] [mm] ATA03EDA ATA04EDA ATA05EDA ATA06EDA ATA07EDA øE...
  • Page 4: Installation

    Installation supporting brackets (not supplied) air ducts (not supplied) external damper Right Handling Left handling VERSION MACHINES VERSION MACHINES ATB**R** ATB**L** DUCT Exhaust air Fresh air Return air Supply air Unit duct, example...
  • Page 5 External damper can be positioned both horizontally and vertically. The ducts and the external damper must be permanently fixed to a fixed structure (for example a wall or a ceiling) using brackets (not supplied). External damper should be installed in such a way that it is accessible for maintenance or any other operation.
  • Page 6 Connection of External Dampers ATE00AMDA - Modulating Actuator AUE00ASDA - Spring Return Actuator Set the pointer to the “0” position. Close the throttle valve The actuator assembly instructions are contained in the actuator packaging. Installation of actuator...
  • Page 7 A = Outdoor/Exhaust modulating damper (with provided mixing damper) B = ON/OFF Damper Exhaust air Outdoor air Return air Supply air Cable not supplied Connect according to the wiring diagram Right Handling VERSION MACHINES ATB**R** Connection of external Dampers...
  • Page 8 provided A = Outdoor/Exhaust modulating damper (with mixing damper) B = ON/OFF Damper Exhaust air Outdoor air Return air Supply air Cable not supplied Connect according to the wiring diagram Left handling VERSION MACHINES ATB**L** Connection of external Dampers...
  • Page 9: Testing Procedure

    Testing procedure | ON/OFF damper. Switch on the machine WARNING! Internal parts of the Check if the flap moves until full open machine under voltage position. If not, check the actuator’s wiring connection Testing procedure...
  • Page 10 Software setup Commissioning module ALC00895A is required. Compact T psw:2526...
  • Page 11 Testing procedure | Outdoor and exhaust damper when mixing damper is installed inside the unit Check if the throttle valve state is complementary to Mixing Damper state. For example: throttle valve open and Mixing Damper • closed= correct throttle valve open at 30% and Mixing •...
  • Page 12 La presente pubblicazione è redatta solo come supporto tecnico e non costituisce impegno vincolante per Daikin Applied Europe S.p.A. Daikin Applied Europe S.p.A. ne ha compilato il contenuto al meglio delle proprie conoscenze. Nessuna esplicita o implicita garanzia è data per la completezza, precisione, affidabilità...