Time Electronics 7161-VLP User Manual

Pressure calibration manifold with vernier control

Advertisement

Quick Links

User Manual
7161-VLP
Pressure Calibration Manifold
with Vernier Control
Version 1.1
6-24
Time Electronics Ltd
Unit 5, TON Business Park, 2-8 Morley Road,
Tonbridge, Kent, TN9 1RA, United Kingdom.
T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198
mail@timeelectronics.co.uk | www.timeelectronics.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7161-VLP and is the answer not in the manual?

Questions and answers

Summary of Contents for Time Electronics 7161-VLP

  • Page 1 Pressure Calibration Manifold with Vernier Control Version 1.1 6-24 Time Electronics Ltd Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom. T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 mail@timeelectronics.co.uk | www.timeelectronics.com...
  • Page 2 All rights reserved. Nothing from this manual may be multiplied, or made public in any form or manner, either electronically or hard copy, without prior written consent from Time Electronics Ltd. This also applies to any schematics, drawings and diagrams contained herein.
  • Page 3: Table Of Contents

    Time Electronics 7161-VLP Pressure Calibration Manifold with Vernier User Manual Contents Introduction ............................ 4 Description ............................. 4 Features ..............................5 Specifications ..........................5 Warnings ............................6 Operation ............................7 Connections and Controls ........................7 Example Test Setup ..........................8 Operating Instructions ........................... 9...
  • Page 4: Introduction

    Thread configurations are selectable upon request. Standard models have output ports with 2 x 1/4” BSP female (7161-VLP) or 2 x 1/4” NPT (7161-VLP-NPT). Other threads are available, and can be built with a combination, for example 1 x 1/4" NPT and 1 x 1/2" NPT.
  • Page 5: Features

    (RAL 7035 grey) with polyurethane feet. UUT quick connections ....Finger-tight connectors (2 on top). UUT connection thread ....7161-VLP: 1/4" BSP 7161-VLP-NPT: 1/4" NPT Other thread options: 1/2" BSP, 1/2" NPT, M20 Input connection ......
  • Page 6: Warnings

    Do not over-tighten the input or output connectors as this can damage the threads. The 7161-VLP manifold does not vent. It only provides a fine adjustment of small pressure to enable an accurate set point to be achieved. Venting must be performed by the regulated input.
  • Page 7: Operation

    Time Electronics 7161-VLP Pressure Calibration Manifold with Vernier User Manual Operation Connections and Controls Output port Output port Vernier Input port...
  • Page 8: Example Test Setup

    Time Electronics 7161-VLP Pressure Calibration Manifold with Vernier User Manual Example Test Setup Regulated Pressure Source Reference Pressure Gauge 7161-VLP Manifold...
  • Page 9: Operating Instructions

    Time Electronics 7161-VLP Pressure Calibration Manifold with Vernier User Manual Operating Instructions NOTE: During operation you will use the pressure source in conjunction with the vernier. The manifold vernier DOES NOT VENT pressure. It only provides a fine setting adjustment.
  • Page 10 Time Electronics 7161-VLP Pressure Calibration Manifold with Vernier User Manual 7. To adjust the pressure via the vernier, turn the large knob clockwise for positive pressure, anticlockwise for negative pressure. 8. For ultra fine control, the small inner dial knob can be used.
  • Page 11: Warranty And Servicing

    Time Electronics’ total liability is limited to repair or replacement of the product. Note that if Time Electronics determine that the fault on a returned product has been caused by the user, we will contact the customer before proceeding with any repair.
  • Page 12: Returning Instruments

    User Manual Returning Instruments Prior to returning your product please contact Time Electronics. We will issue a return merchandise authorization (RMA) number that is to accompany the goods returning. Further instructions will also be issued prior to shipment. When returning instruments, please ensure that they have been adequately packed, preferably in the original packing supplied.