UNICONTROL Electronic MV-05E Operating And Installation Instructions

Magnetic valve control with remote on/off input

Advertisement

Quick Links

1
Description .............................................................................................. 2
2
Frontal View ............................................................................................ 2
3
Function ................................................................................................... 3
4
Installation ............................................................................................... 4
4.1 Cabling ................................................................................................................. 4
4.2 Connection Plan ................................................................................................... 5
5
First Use and Configuration ................................................................... 6
6
Technical Data......................................................................................... 7
6.1 MV-05E, MV-10E .................................................................................................. 7
6.2 Connectable Magnetic Valves .............................................................................. 8
7
Warning Notices ...................................................................................... 8
7.1 Danger of the Devices .......................................................................................... 8
7.2 Permitted Users .................................................................................................... 8
7.3 Intended Use ........................................................................................................ 8
7.4 Electrical Connections .......................................................................................... 9
7.5 Installation ............................................................................................................ 9
7.6 Maintenance ......................................................................................................... 9
UNICONTROL Electronic GmbH
Freinsheimer Straße 3
Operating an Installation Instructions
Magnetic Valve Control
with remote ON/OFF input
MV-05E
MV-10E
68219 Mannheim
MV-05E
1
/9
Tel.: +49 621 87982 0
MV-10E
Magnetic Valve Control
with remote ON/OFF input
for 5 or 10 Magnetic Valves
12-05-2024
info@ucma.de
www.ucma.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MV-05E and is the answer not in the manual?

Questions and answers

Summary of Contents for UNICONTROL Electronic MV-05E

  • Page 1: Table Of Contents

    4.1 Cabling ......................... 4 4.2 Connection Plan ....................5 First Use and Configuration ..............6 Technical Data..................7 6.1 MV-05E, MV-10E ....................7 6.2 Connectable Magnetic Valves ................8 Warning Notices ..................8 7.1 Danger of the Devices ..................8 7.2 Permitted Users ....................
  • Page 2: Description

    MV-05E; MV-10E Description The magnetic valve controller MV-10E or MV-05E controls and monitors up to 5 or 10 magnetic valves. The connected valves (230V ) are monitored for wire or coil breakage. They are protected in the device with fuses. Unused channels can be deactivated.
  • Page 3: Function

    MV-05E; MV-10E Function Normal Conditions ● The green LED lights up indicating correct supply voltage. ● All red LEDs of the device are OFF. ● The key switch stay at ON position. ● All activated MV green LEDs light-up. ● The relays “Fail” and “Emergency Stop” are ON (contacts S and NO connected) → the “Fail”...
  • Page 4: Installation

    MV-05E; MV-10E ● The red "Emergency Stop" LED blinks. ● All green MV LEDs are OFF. ● The internal piezo buzzer beeps indicating the "Emergency Stop" situation. The acoustic mes- sage can be stopped by pressing the Quit button. ● The "Emergency Stop" relay is turned OFF (S and NC connected) → the message is active.
  • Page 5: Connection Plan

    MV-05E; MV-10E 4.2 Connection Plan UNICONTROL Electronic GmbH 12-05-2024...
  • Page 6: First Use And Configuration

    MV-05E; MV-10E First Use and Configuration Warning! The MV-5E and MV-10E devices are not suitable for installation in Explosion Zone (Ex. Zone). The device itself must be installed outside of Ex. Zone! X1 – X10: MV Channels – connections for the magnetic valves.
  • Page 7: Technical Data

    MV-05E; MV-10E Technical Data 6.1 MV-05E, MV-10E Parameter Sym. Conditions Unit Operating Voltage 50/60 Hz 207V ≤ U ≤ 240V , without MVs Power Consumption Relay-Outputs Rated vol- X11, X12: tage MV-Failure Changeover contact, Emergency Stop potential free, Rated current...
  • Page 8: Connectable Magnetic Valves

    The minimum age for users is 18 years. 7.3 Intended Use The unit of MV-05E/-10E is exclusively qualified for the monitoring of solenoid valves in normal rooms without potentially explosive areas, so, it may not be installed in environment with risk of explosion.
  • Page 9: Electrical Connections

    7.5 Installation Before installation, it must be verified that all requirements for trouble-free operation are met: ● Are the MV-05E/-10E and the magnetic valves mounted correctly? ● Is the MV-05E/-10E accessible and visible? ● Are there required environment conditions for installation and operation? ●...

This manual is also suitable for:

Mv-10e

Table of Contents