Contents Product List Product Description 02-04 Specifications Function Description LCD Screen Description Instructions for Use 05-06 Recharge Methods 07-09 AC Charging 07-08 Solar Charging Car Charging Other Functions 10-12 Boost Mode Frequency Switching AC Input Overload Protection 11-12 EPS Mode Error Code &...
Page 4
Disclaimer Before using this product, please read this user manual carefully to ensure that you fully understand the product and can use it correctly. After reading this user manual, please keep it in a safe place for future reference. Improper use of this product may cause serious injury to yourself or others, or result in product damage and property loss.
Available On Available On You can connect this product via APP to view information, control the device and personalize settings. Scan the QR code to down- load our Smart Control APP. What's in the Box Power Station User Manual*1 Warranty Card*1 Brand Card*1 Lighter to Anderson AC Charging Cable*1...
Parameter Specifications Output Technical Parameters Rated Voltage 120Vac Rated Power 2400W AC Output Boost Mode Power 2600W Peak Power 4500W Frequency 60Hz Rated Voltage DC 12V & Car Lighter Output Rated Current USB-A Output 5V/3A; 9V/2A; 12V/1.5A【18W Max】 USB-C Output 5V3A,9V3A,15V3A,20V5A,28V5A【140W Max】...
Product Description Function Description USB-C Main Power IOT Button Car Charger DC 5521 Output Port Output Port Output Port Button LCD Screen USB-A AC Output Power AC Output DC Output Power Button Output Port Button Port AC Input PV Input Overload Protection AC Input...
Product Description LCD Screen Description Remaining discharge Battery Capacity WiFi& Input Power time display Percentage Bluetooth Display Battery Capacity Output Power Error Warning Circle Display AC Output USB-C Car Charging Cooling Indicator Indicator Indicator USB-A DC 5521 High temperature Low temperature Indicator Indicator protection...
Instructions for use Power On: Main Power: Press and hold the main power button for 3 seconds. The capacity circle and percentage will light up, confirming the screen is functioning. The button light will light up and switch to a breathing mode, indicating the power is on.
Page 10
LCD Screen Sleep Mode: When the main power is on, short press the main power button, the LCD Screen will go out, while the power station is still functioning. When the AC/DC output power button is on as well, it will switch to sleep mode automatically within 5 minutes of inactivity and the LCD screen will automati- cally go out.
Recharge Methods AC Charging Connect AC charging cable to connect the power station as shown in the above picture. The input power will be displayed on the screen, showing that the device starts charging. Solar Charging Use Anderson-MC4 charging cable to connect anderson connector with PV input port on the power station, red cable to red port and black cable to black port.
Page 12
Solar Charging Connection Guide Connect 3 OUPES 240W solar panels at most in series to get maximum power at 719.55W. Notice: 1. Make sure the solar panels meet the following requirements: OCV: 78V;Current: 13A;Max Power: 800W 2. Make sure that the solar panel is positioned at a perpendicular angle to the sun's rays for the best solar energy conversion efficiency. 3. OUPES 240W solar panel is an optional accessory for the power station.
Recharge Methods Car Charging The car charging port supports 12-15.5V/8.5A car charging input electricity. To protect your car battery from power loss and prevent the car from being unable to start, please ensure that the car is started before connecting car charging cable to cigarette lighter. At the same time, please check if the car charging port and the cigarette lighter of the car charging input cable are in good connection.
Other Functions Boost Mode To prevent operational failures caused by overload protection, the power station automatically activates Boost Mode when the total output power exceeds the rated 2400W output power. It enables the power station to supply up to 2600W power to high-wattage devices.
AC Input Overload Protection If the AC input receives a continuous current that is greater than 20A, the protector will blow. And the circuit will be cut off to protect the power station. Please disconnect all the input connections for safety reason, and make sure the input current is lower than 20A.
Page 16
EPS(Emergency Power Supply) Function Notice: 1.This is not a professional UPS function and does not support 0ms switching. Thus, do not connect the powe station to equipment requiring an uninterrupted power supply such as data servers, work station and so on. 2.
Error Code & Trouble Shooting Error Status Cause Solution Code AC output short circuit Press the AC output power on/off E000 button for restore. protection Flashing, no output The function icon indicates which path is overloaded. Overload Output overload E001 protection requires manual protection Flashing, no output...
Page 18
Error Code & Trouble Shooting Error Status Cause Solution Code Overload and short Need to manually press the DC E012 circuit of the USB-C switch to restore Flashing, no output port at all ports Restart the corresponding function DC Discharge Battery E013 E013 no output at all ports button to restore the function after...
Storage and Maintenance Please use a dry, soft, clean cloth or paper towel to gently wipe the product. Please store the power station away from water resources, heat resources, metal objects and chemical substances. Store it in a dry, well-ventilated place at room temperature. The recommend- ed storage temperature is -4°F-149°F (-20°C-65°C).
1. What type of battery does the product use? The Exodus 2400 uses high-quality lithium iron phosphate (LiFePO4) batteries. 2. What equipment can be connected to the AC output port? The AC output port has a rated power is 2400W, peak power is 4500W, making it suitable for most household appliances.
Need help?