Contents Introduction Safety Explanation of symbols Safety instructions Personnel qualification Risk of electric shock! Correct operating environment Important Commissioning Technical parameters Description of floor convector Convector installation and electrical Connection standard delivery contents Construction section Installation manual Inspection before concreting Connection to electrical system Electric wiring diagrams of the convector First start-up inspection...
Introduction KORAFLEX Amper FVA (230 V AC) is a fully electric floor-mounted convector which, in order to achieve high heating output and rapid heat transfer to the space, contains a powerful electric heat exchanger and an EC tangential fan. Reliable regulation ensures simple and safe operation, while guaranteeing that the walkable cover grille does not reach too high a temperature.
Personnel qualification • The electrical installation design must be carried out by a person with appropriate professional compe- tence and must comply with the relevant standards. • The convector may only be installed, connected, repaired and commissioned by a trained specialist. •...
Important • Do not cover the floor grille of the convector. Overheating and device blockage may occur (see chap- ter Device malfunctions). • Do not sit on the convector grille or place any objects on it. • Prevent objects from falling into the convector. If this occurs, immediately disconnect the convector from the mains and remove the fallen object.
Convector installation and electrical Connection standard delivery contents Max. 75 °C 6 mm 4× 4× Construction section The assembly and installation of the convector must be carried out in accordance with the general con- struction, safety and installation regulations and standards valid at the given location. Install the convector according to the enclosed installation manual.
Installation manual Grille removal WINDOW min. 50 mm min. 50 mm Inspection before concreting • Check the correctness of electrical connection • The convector is properly positioned and levelled • All punched holes in the convector are carefully insulated against concrete screed ingress...
Page 9
Convector anchoring to the floor 20 mm Not included in the package...
Connection to electrical system • According to the wiring diagram, connect the 230 V AC power supply to terminals L, N and PE • Equip the electrical network with a circuit breaker required according to the values specified in Technical parameters of KORAFLEX Amper FVA convector (page 5) and according to the standards of the given country.
Control Functional description The device operates on the principle of an electric resistance element fitted with fins, from which heat is forced upwards into the room by an air current generated by a fan. The heating element and fan output is continuously regulated by a control voltage of 0–10 V DC from a thermostat, BMS or other control device.
Do not make any modifications to the convector that would alter its function. Further maintenance require- ments can be found at www.licon-heat.com or www.korado.cz in the current Warranty and Post-warran- ty Terms and Conditions.