  • Page 1 TRTS / TRTSB / TRTSL / TRTSLB 7 Day Programmable Timer Installation & User Guide...
  • Page 2: Table Of Contents

    Contents Installing the timer User Interface Setting the date & time Heating modes Advanced settings Setup your heating schedule Factory Reset Temporary override Holiday Mode Key lock Technical data Service and support 1300 368 631 www.thermogroup.com.au...
  • Page 3: Installing The Timer

    Unplug the cable connector from the back of the timer screen. Connect the Thermorail towel rail to the timer as seen in the below wiring diagram. 220-240V AC Supply Live 220-240V AC Supply Neutral 240V Output Thermorail Neutral 240V Output Thermorail Live Not Required Not Required www.thermogroup.com.au 1300 368 631...
  • Page 4 Screw the back plate of the timer to the electrical plate. Plug the cable connector into the back of the timer screen and connect the screen to the back of the timer. 1300 368 631 www.thermogroup.com.au...
  • Page 5: User Interface

    1. Day indicator 2. Key lock icon 3. Schedule mode icon 4. Manual mode icon 5. ON/OFF indicator 6. Confirm settings 7. Program button 8. Mode button 9. Power button 10. Up & down arrows 11. Time www.thermogroup.com.au 1300 368 631...
  • Page 6 1. Day indicator 7. Program button 2. Key lock icon 8. Mode button 3. Schedule mode icon 9. Power button 4. Manual mode icon 10. Up & down arrows 5. ON/OFF indicator 11. Time 6. Confirm settings 1300 368 631 www.thermogroup.com.au...
  • Page 7: Setting The Date & Time

    Setting the date and time Press and the time will begin to flash to select the correct time Press until the day begins to flash (Note: Monday is Day 1) to select the correct day Press to save the settings www.thermogroup.com.au 1300 368 631...
  • Page 8: Heating Modes

    Manual Mode In manual mode press the to set the ON/OFF status. Schedule Mode In the schedule mode the timer will follow the heating schedule that is set. Refer to page 10 for programming instructions. 1300 368 631 www.thermogroup.com.au...
  • Page 9: Advanced Settings

    Menu Description Range Default Clock Format 12 or 24 5+2 or 7 Day 01=5+2 Day Program 01=5+2 Day Programming 02=7 Day Program Program ON = Activated Screen Saver OF=Not Activated OF = Not Activated www.thermogroup.com.au 1300 368 631...
  • Page 10: Setup Your Heating Schedule

    Press and the ON / OF will flash. Using the select ON for P1. Press to set period 2, which is when the rail will turn off. Use the to adjust the time. 1300 368 631 www.thermogroup.com.au...
  • Page 11 OF for both P3 and P4 and ensure that the time set for P3 and P4 is after the time set for P2. When Monday-Friday has been set, press to go onto the Saturday and Sunday schedule. www.thermogroup.com.au 1300 368 631...
  • Page 12 2, which is when the rail will turn off. Use to adjust the time. Press and the ON / OF will flash. Using the select OF for P2. Repeat above steps for P3 and P4. 1300 368 631 www.thermogroup.com.au...
  • Page 13 If programming all 7 days individually use the to select the day to program first. If programming all 7 days to the same schedule, press and hold button for about 5 seconds to select all 7 days. www.thermogroup.com.au 1300 368 631...
  • Page 14 ON for P1. Press to set period 2, which is when the rail will turn off. Use the to adjust the time. Press and the ON / OF will flash. Using the select OF for P2. 1300 368 631 www.thermogroup.com.au...
  • Page 15 If programming all 7 days to the same schedule, the program is now set up. If programming all 7 days individually, press and use the to select the next day to program and repeat above steps. www.thermogroup.com.au 1300 368 631...
  • Page 16: Factory Reset

    Press and the hold until is displayed Press and hold for approx. 5 seconds will display on the screen and then the timer has been reset. Turn the timer back on to setup the program 1300 368 631 www.thermogroup.com.au...
  • Page 17: Temporary Override

    In schedule mode, press the and the ON/OFF display will flash. to adjust the desired setting and press confirm. will be displayed below the ON/OFF display. To cancel the override setting press www.thermogroup.com.au 1300 368 631...
  • Page 18: Holiday Mode

    This timer does not have a dedicated holiday mode. To suspend the heating schedule for a period of time turn the timer off using button. This will ensure the heating schedule is held and then to resume the heating schedule press the button. 1300 368 631 www.thermogroup.com.au...
  • Page 19: Key Lock

    To unlock press and hold the until disappears. Technical Data Technical Specification Stock code Size WxHxD (mm) Colour Warranty TRTS 80 x 120 x 45 (27mm in wall) White 2 Years TRTSB 80 x 120 x 45 (27mm in wall) Black 2 Years TRTSL...