Combustion Air and Venting
SECTION II - Combustion Air and
Venting

Combustion Air Contamination

WARNING
If the PERFORMANCE PLUS combus-
tion air inlet is located in any area likely
to cause or contain contamination, or if
products, which would contaminate the
air cannot be removed, the combustion
air must be repiped and terminated to an
outside location. Contaminated combus-
tion air will damage the unit and its
b u r n e r system, resulting in possible
severe personal injury, death or substan-
tial property damage.
WARNING
Do not operate a PERFORMANCE
PLUS if its combustion air inlet is taken
inside in a laundry room or pool facility.
These areas will always contain haz-
ardous contaminants.
Pool chemicals, laundry products, com-
mon household cleaners
products often contain fluorine or chlo-
rine compounds. When these chemicals
pass through the burner and vent sys-
tem, they can form strong acids. These
acids can create corrosion of the outer
tank, burner components and vent sys-
tem, causing serious damage and pre-
senting a possible threat of flue gas
spillage or water leakage into the sur-
rounding area.
Please read the information listed below.
If contaminating chemicals are located
near the location of the combustion air
inlet, the installer should pipe the com-
bustion air inlet to an outside area per
SECTION VI of this installation manual.
Potential contaminating products
-
-
-
-
-
-
-
-
-
-
-
-
-
Areas likely to contain these products
and hobby
-
-
-
-
-
-
-
-
-
-
-
-
7
Spray cans containing chloro/fluorocar-
bons
Permanent Wave Solutions
Chlorinated wax
Chlorine - based swimming pool chem-
icals / cleaners
Calcium Chloride used for thawing ice
Sodium Chloride used for water soften-
ing
Refrigerant leaks
Paint or varnish removers
Hydrochloric acid / muriatic acid
Cements and glues
Antistatic fabric softeners used in
clothes dryers
Chlorine-type bleaches, detergents, and
cleaning solvents found in household
laundry rooms
Adhesives used to fasten building prod-
ucts and other similar products
Dry cleaning / laundry areas and estab-
lishments
Beauty salons
Metal fabrication shops
Swimming pools and health spas
Refrigeration Repair shops
Photo processing plants
Auto body shops
Plastic manufacturing plants
Furniture refinishing areas and estab-
lishments
New building construction
Remodeling areas
Garages with workshops