Page 5
Important! When using this equipment, a few safety precautions must be observed to avoid injuries and damage. Please read the complete operating manual with due care. Keep this manual in a safe place, so that the information is available at all times. If you give the equipment to any other person, give them these operating instructions as well.
Page 6
13. Keep children and other unauthorized persons away from the machine. 14. Do not pull loads sideways or from one side. Do not allow the load to swing. 15. Ensure that the hook moves in the same direction as shown on the control switch. 16.
Page 7
11. Remote control 12. Power cable 13. Control cable 14. Motor 15. Return roller 16. Additional hook 17. Cable for remote control 3. Technical data Type PA200M PA300M PA400M PA500M PA600M PA800M PA1000M Rated voltage Rated frequency Power consumption 500W...
Page 8
the machine’s capacity. The equipment is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse. The user / operator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this.
Page 9
control mechanism for signs of possible transit damage. 6.2 Assembly (Fig. 5) The cable hoist is fitted with two fastening clamps (1) with which it has to be fastened to a rectangular tube. The dimensions of the arm must conform with the size of the fastening clamps and must be capable of supporting twice the rated load.
Page 10
be taut when the load is raised. 7. The motor (14) for the cable hoist is fitted with a thermostat switch. Whilst the cable hoist is operating, the motor (14) may therefore stop. It will restart automatically when it has cooled down.
Page 11
Overload cable winch is not suitable continuous operation. The motor is protected from overload and overheating by a temperature switch. If the permissible operating time is exceeded, the motor temperature will increase the temperature switch will shut the cable winch off.
Page 12
In the following: One cycle means one raising and lowering movement of a load. Periodic inspection means an inspection after 100 cycles. Test periodically that the limit switches on the cable hoist are in correct working order. Conduct this test as follows: When the cable has reached the maximum height, the lever on the automatic stopping mechanism (5) will be actuated.
Page 13
Never place any electric tools in your household refuse. To comply with European Directive 2012/19/EV concerning old electric and electronic equipment and its implementation in national laws, old electric tools have to be separated from other waste and disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot.
Problem-Solving Common Malfunction Cause Solution The Off-On-Switch is used but 1. It is not plugged into the power 1. Connect the item to the power supply. the motor does not turn supply. 2. The wires are broken or ripped. 2. Check the wires and plug it in 3.
Need help?
Do you have a question about the PA200M and is the answer not in the manual?
Questions and answers