Advertisement

Quick Links

Owner and
Operational Manua
Model:
Serial Number:
Install Date:
Installed By:
Service Phone:
Sold By:
Please read this manual carefully before proceeding with installation. Your failure to
follow any of these instructions or operating parameters may lead to personal injury
or damage to the equipment and/or personal property. Do not use this water
treatment system with water that is microbiologically unsafe or of unknown quality,
without adequate disinfection before or after the system. This water treatment
system contains replaceable treatment components critical for effective
performance. It is the user's responsibility to periodically test the product water to
verify the system is performing satisfactorily. Failure to properly maintain this water
treatment system may cause a health risk.
Save this manual for future reference
l
Aqua Magic DROP CS 121 Series
4.17.2024 SB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AQUA MAGIC CS Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Frakco AQUA MAGIC CS Series

  • Page 1 Owner and Operational Manua Model: Serial Number: Install Date: Installed By: Service Phone: Sold By: Please read this manual carefully before proceeding with installation. Your failure to follow any of these instructions or operating parameters may lead to personal injury or damage to the equipment and/or personal property.
  • Page 2: Table Of Contents

    Table of Contents Operations ........................4 Detailed Valve Description ....................4 Operations ........................5 Operations Drop Valve - Lights - Regeneration ..............6 DROP Lights - During Regeneration..................6 Softener ........................6 Operations Advanced Configurations ..................7 Advanced Configuration of Valve Device Components ..............7 Operations Advanced Configurations ..................
  • Page 4: Operations

    Operations Detailed Valve Description The DROP 121 valve is fully automatic control mechanisms to direct and regulate all cycles of the water treatment unit. The control valve has been designed to make it easily serviceable. The inlet, outlet, drain and access to the water meter are all hand only tighten nuts making them quick and convenient to ser- vice.
  • Page 5: Operations

    Operations CSD121 Bypass Operation Service Bypass...
  • Page 6: Operations Drop Valve - Lights - Regeneration

    Operations Drop Valve - Lights - Regeneration DROP Lights - During Regeneration When a treatment valve is in regeneration the lights will change color for each step in the regeneration process. While the valve is sitting in a step of the regeneration process the lights will be slowly fading from side to side (wobble).
  • Page 7: Operations Advanced Configurations

    Operations Advanced Configurations Advanced Configuration of Valve Device Components The DROP valve board is used on several configurations of DROP products. These products will come with the board already setup, ready to use for most installations. Valves from the factory are preset as follows: •...
  • Page 8: Operations Advanced Configurations

    Operations Advanced Configurations Steps for advanced configuring of valve device components Follow the steps below to change the device configuration of a board, or these steps can be followed to find out what the current configuration of a board is set to. 1.
  • Page 9: Operations Quick Reference Table

    Operations Quick Reference Table Valve specifications, Quick Reference Table Valve Series - Piston Type CSD125 – NHWB – 2.5” CSD125 – HWB – 2.5” with Tank Opening with Bypass Valve Bypass Valve Service Flow Rate @ 15 psig (with meter) 25.5 27.7 Service Flow Rate @ 25 psig (with meter)
  • Page 10: Operations Injectors

    OPERATIONS INJECTORS Valve Control Board Connections The valve board wiring connections are labeled clearly according to their function. “Ext. Input” and “Ext. Mtr.” are normally unused. For specific installations, the Ext. Mtr. output can be used to run an external valve.
  • Page 11: Operations Connections

    OPERATIONS CONNECTIONS Brine Line Push-Lock Connection To connect the brine tubing to the brine port on the valve: 1. Make sure the 3/8” brine tubing is cut squarely on the end. 2. Push the tubing into the fitting 7/8” to be sure it is past the O-ring seal. To release the brine tubing from the brine port on the valve: 1.
  • Page 12: Csd121 Valve Parts - Valve Breakdown

    CSD121 Valve Parts - Valve Breakdown DRAWING A (Pg. DRAWING B (Pg. Part No. Description Qty. 20125X001 Encoder Wheel and Piston Rod Assy. 20125X002 Valve Body Seal Plate with O-Ring 20125X003 Piston Spacer / Stall Ring 20125X004 Softener Piston (Hardwater Bypass) 20125X005 Softener Piston (No Hardwater Bypass) 20125X023...
  • Page 13 CSD121 Valve Parts - Brine Connection Part No. Description Qty. 20125X034 3/8” Push-Lock Brine Line Fitting 20125X035 Brine Line Flow Control, 1.0 gpm 20125X014 Brine Line Flow Control Retainer 20125X015 Red Locking Clip 20125X025 Optional Brine Plug for Filter Valves...
  • Page 14 CSD121 Valve Parts - Check Valve & DLFC Part No. Description Qty. 20017X301 Fitting Nut 20018X313 Screen 20018X312 Screen Body 20017X292 Check Valve Housing 20121X005 Air Inlet Check Valve 20017X002 Check Valve Retainer CS-AD-BLFC-3 CS Valve Injection Adapter 20125X015 Red Retainer Clip Part No.
  • Page 15: Injector Assembly

    CSD121 Valve Parts - Injector Assembly Part No. Description Qty. CS-DLFC-2.4 Drain Line Flow Control, 2.4 gpm CS-DLFC-3.5 Drain Line Flow Control, 3.5 gpm CS-DLFC-4 Drain Line Flow Control, 4 gpm CS-DLFC-5 Drain Line Flow Control, 5gpm CS-DLFC-8 Drain Line Flow Control, 8 gpm CS-DLFC-9 Drain Line Flow Control, 9 gpm CS-DLFC-10...
  • Page 16: Csd121 Power Head

    CSD121 Power Head Part No. Description Qty. 20125X017 Commercial Slide Cover Bracket 20125X018 Commercial Slide Cover 20125X019 Geared Piston Motor EVB-029 Commercial Control Board 20125X020 Optical Position Encoder 20125X021 Commercial Power Head Backplate 20125X007 Meter Assembly 20125X027 Power Supply 1A 12VDC 10 ft. Cord...
  • Page 17: Valve Body Flow Diagrams

    Valve Body Flow Diagrams Untreated water bypassing during regeneration piston Note: Brine Piston for Softeners only Service Outlet Shutoff...
  • Page 18 Backwash Downflow Brine...
  • Page 19 Rinse Brine Fill...
  • Page 20: Valve Body Flow Diagrams

    Valve Body Flow Diagrams Outlet water shutoff during regeneration piston Note: Brine Piston for Softeners only Service Outlet Shutoff...
  • Page 21 Backwash Downflow Brine...
  • Page 22 Rinse Brine Fill...
  • Page 23: Water Treatment System Warranty

    Replacement items will be shipped by FRAKCO F.O.B. Luverne, Minnesota, with a shipping carton furnished. In the event certain models or colors of the replacement item are out of stock, FRAKCO, INC. may, after notifying the purchaser, furnish another model or color of the replacement item. The factory will not pay for service charges and will not perform any repair or service functions other than at its home office.

This manual is also suitable for:

Aqua magic drop cs 121

Table of Contents