Page 1
Electric bike repair stand 2.0 SCALE CALIBRATION PROCEDURE Scale calibration is required, if the following spare parts are replaced: 1. Middle assembly 2. Chain assembly 3. Scale electronics 4. Upper assembly 1. Drive the clamping master arm to a height of 110 cm 2.
Page 2
the second step requires to hang the weight between 5 kg and 10 kg on the master arm. By rotating the STOP button set the value on middle display that is equal to real weight that is hanged on master arm. Then confirm this step by holding the STOP button pressed again for about 3 seconds (in our case, we hung 7 kg on the master arm and set the number 7 on the control panel as shown on picture below.
Page 3
In third, last step, it requires to hang on the weight in the range between 60 kg and 70 kg, as indicated by value 60 on upper display an 70 on lower display. Repeat the process of setting the middle-display number to match the real weight on the master arm. Then confirm this step by holding the STOP button pressed again for about 3 seconds (in our case, we hanged 67 kg on the master arm and set the number 67 on the control panel as shown on picture below.