PRODUCT INTRODUCTION
1. Product Introduction
eLOG01, matched with the controller of the RS485 interface, is a record
accessory. It can record solar system working data and real-time monitor
system status via PC software or MT50. Default record interval is every
10 minutes, with a record range of 4 months.
Features:
 Record & download system data
 Compatible with PC software & MT50 for real-time monitoring
 Connect to PC via USB interfaces with high compatibility
 Powered up by controller communication interface
 Record capacity: 20000 points(MAX)
 LED Indicator design, more intuitive display
2. Product Features
B
A
Item
A
DEVICE COM interface (RJ45)
B
Reload button
C
Working indicator
D
PC USB interface (Micro USB)
E
RS485 COM interface(RJ45)
F
CR1220 (Button cell holder)
NOTE: After rebooting the controller, please adjust the clock
accurately; otherwise, it will lead to eLOG01 time disordered or
data loss.
NOTE: eLOG01 must be installed with a CR1220 battery
(additional purchased by customer); otherwise, the data stored
in the recorder will be lost after the controller is powered off.
3. Reload Button
Operation
The indicator flashes once, eLOG01 is normal
Press the button
The indicator is OFF, eLOG01 is halted
Press the button
Clear the log records and restore factory settings
and hold on 5s
NOTE: When the eLOG01 does not match the controller, you
can press the reload button and hold on 5s to clear this state.
However, the previous data recorded will be removed
simultaneously.
4. Indicator
color
Status
Green
Flashing once
Green
On Solid
Green/Red
OFF
eLOG01 logger, please read
eLOG01—Logger
C
D
E
F
Instruction
Connect the controller
Restore factory settings
Working status
Download and manage data
Real-time monitoring
Store the historical data
Instruction
Instruction
Normal
Normal
Fault or halt
1
Tel:+86-10-82894896/82894112/+86-752-3889706
Red
On Solid
Red
Fast Flashing(2Hz)
Red
Slowly Flashing(1Hz)
5. Function and Software Operation
(1) Data Recording
①RS485 communication cable (Included)
Model: CC-RS485-RS485-200U
Function: Connect the controller and eLOG01
Cable length: 2m
(2) Log Download
 Local download
 Remote download(CR1220 cell is needed)
①RS485 communication cable (Included)
Model: CC-RS485-RS485-200U
Function: Connect the eLOG01 to the controller
Cable length: 2m
②USB communication cable (Included)
Model: CC-USB-USB-150U
Function: Connect the eLOG01 to the PC
Cable length: 1.5m
(3) Software Installation Instructions
Name
Model
Log download
eLOG01
tool
Solar Station
PC software
Monitor
Communication
CH343 driver
cable driver
Download
https://www.epever.com/support/softwares/
website
Website:www.epever.com
Standby
Inconsistent model matching
(ID/SN/models)
Not support this controller
Communication interrupted
Memory chip malfunction
The working indicator is
green, eLOG01 is normal.
Icon
Functions
Download and
inquiry Logs
Real-time
monitoring
Applicable to
eLOG01 with
HV:2.0.0 or later
hardware versions
2

Advertisement

loading
Need help?

Need help?

Do you have a question about the eLOG01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Epever eLOG01

  • Page 1 1. Product Introduction (1) Data Recording eLOG01, matched with the controller of the RS485 interface, is a record accessory. It can record solar system working data and real-time monitor system status via PC software or MT50. Default record interval is every The working indicator is 10 minutes, with a record range of 4 months.
  • Page 2 2) Set the computer port attributes. software or the Remote Meter. ① RS485 communication cable (Included) Model: CC-RS485-RS485-200U Function: Connect the eLOG01 to the controller or the remote meter Cable length: 2m ③ USB communication cable (Optional) Model: CC-USB-RS485-150U Function: Connect the eLOG01 to the PC Cable length: 1.5m...