1.1. About this manual Thank you for choosing the TERRA portable power supply from Hybrid Power Solutions (HPS). We hope you fully enjoy and maximize its capabilities. This manual provides comprehensive guidance on the transportation and storage, mechanical installation, electrical connections, operation (powering on and off), troubleshooting, and maintenance of the product.
Before operating the TERRA, carefully read and fully understand the instructions including all the cautions and safety notices shown on this manual. Following all instructions for proper operation and troubleshooting will reduce the risk of personal injury, death and/or property damage.
2.4. Safety Labels Safety labels are placed on the TERRA to alert you to potential hazards. These labels must not be altered or removed. The following labels are visible when the TERRA is in safe working mode or during maintenance.
Page 11
Appearance may deviate slightly due to ongoing innovation. Fire Fan-In Ventilateur de Secours Fire Fan-In Ventilateur de Secours TERRA - User manual - English...
• Comply with all battery protection requirements and precautions. • Note that the TERRA will not power off immediately. Wait at least 10 minutes to ensure the device is fully de-energized before proceeding with any operation.
N OT I CE To prevent accidents or misoperations caused by unauthorized personnel approaching the TERRA, please observe the following precautions: • Warning signs are placed around the energy storage container to prevent accidents resulting from improper closure. • Place additional warning signs or safety tape near the equipment as a further precaution.
Page 14
Some parts can be recycled and reused, while others may pose environmental hazards. Contact a local authorized recycling agency to ensure proper disposal of the product and its components. TERRA - User manual - English...
This product is widely used for engineering power supply, industrial power applications, power assurance, and backup solutions. All functional indicators of the TERRA meet industry standards, have passed rigorous safety tests, and are designed for reliable and stable operation.
Page 17
Rotate page TERRA - User manual - English...
Page 18
3.3.1. Indicator Lights The TERRA control panel is equipped with three indicator lights, each providing important information about the system’s current status. These lights serve as visual cues to help you quickly assess the operation and health of the system. Below is a table that describes the function of each indicator light, along with its corresponding status.
It consists of four key components: the energy storage system, microgrid control system, digital cloud system, and active safety system. In summary: TERRA = Energy Storage System + Microgrid Control System + Digital Cloud System + Active Safety System TERRA - User manual - English...
Page 20
3.6. System Electrical Schematic Diagram Electrical schematic diagram (Note: The oil engine system is an external oil engine) 3.7. TERRA Port Definition Cabinet Inverter Air Power Line Lifting Points AC Air Inlet Parallel Port Outlet Connection Port TERRA - User manual - English...
Page 21
It features functions such as voltage and temperature monitoring, as well as equalization control for each cell. The module is equipped with a dedicated battery management chip, which receives control commands via daisy chain communication and reports data for monitoring and collection. TERRA - User manual - English...
Page 22
A battery cluster consists of multiple PACKs. The parameters of the battery cluster are provided in the table below. Battery Cluster Parameters Parameter Name Parameter Value Maximum Current 300A DC Output Voltage Range 600~876V Rated Capacity 153.6kWh TERRA - User manual - English...
CA U TI O N Risk of damage to property! The TERRA microgrid power station can only be activated after confirmation from qualified professionals and approval from the local power authority. 3.10. Operation Guidance 3.10.1. Check before powering on Before powering on, please check the following items carefully to ensure they are correct.
Click the login button to access the main interface after successful login. If you are unable to log in, check the network connection. (Please contact customer service to obtain your login account and password.) TERRA - User manual - English...
Page 25
Follow these setup steps: 1. Access the Policy Information Configuration Interface: • Click on the main menu to display the menu bar. • Navigate to Menu Bar --> Policy Information to open the policy information TERRA - User manual - English...
Page 26
• After selecting the desired control strategy, click the Save button to apply the configuration. • The system will automatically manage the operation of energy storage and diesel units based on the selected strategy, actual working conditions, and configured parameters. TERRA - User manual - English...
Page 27
The definitions of the automatic mode parameters are as follows: Serial # Parameter Name Parameter Meaning Remark Power when the system switches to pure off-grid Off-grid load lower limit state Intelligent power-guaranteed Intelligent power retention value of energy storage system TERRA - User manual - English...
Page 28
To view detailed real-time parameters of the energy storage system, click on the main menu --> ‘Energy Storage Information’ or select the energy storage icon on the main interface. This will open the energy storage detailed information interface, as shown below. TERRA - User manual - English...
Page 29
To view detailed real-time parameters of the load, click on the main menu --> ‘Load Information’ or select the load icon on the main interface. This will open the load detailed information interface, as illustrated below. TERRA - User manual - English...
Page 30
3.11.6. History Click on the main menu --> “History Information” to access the history interface. 1. In the history record interface, you can view equipment fault records, system status logs, and operation records individually. TERRA - User manual - English...
Page 31
2. Click Curve Record to view the historical data curve of the device. To export the current curve data, click the data icon on the upper right side of the curve record. TERRA - User manual - English...
• Clear all obstacles, such as trees, cables, or other potential hazards, from the transport path. • Whenever possible, transport the equipment under favorable weather conditions. • Set up warning signs or safety tape to prevent unauthorized personnel from TERRA - User manual - English...
• Avoid exposure to mechanical impacts, heavy pressure, strong magnetic fields, and direct sunlight. Be mindful of environmental conditions such as sudden temperature changes or collisions, which could damage the product. • Do not tilt or invert the packaging box during storage. TERRA - User manual - English...
Page 35
Storage period exceeding 6 months • If the TERRA has been stored for more than six months, it must be charged and discharged to bring the system’s State of Charge (SOC) to between 50% and 80%. The SOC must remain consistent after recharging.
• Avoid areas where toxic, harmful gases are concentrated, and keep the equipment away from flammable, explosive, and corrosive materials. • To minimize noise, install the equipment away from residential areas. 5.2.2. Foundation requirements TERRA - User manual - English...
Page 38
Determine the specifications and quantity of perforation tubes based on the cable type and the number of incoming and outgoing wires. Temporarily seal both ends of all embedded pipes to prevent impurities from entering. This will avoid complications during later wiring. TERRA - User manual - English...
Page 39
N OT I CE The device jack is exposed before delivery. It is recommended to seal the jack with the provided sealing plate after the on-site installation. 5.4. Lifting and Transportation 5.4.1. Lifting Precautions TERRA - User manual - English...
Page 40
• When positioning the equipment, lower it gently and ensure a smooth landing. • Swinging the spreader to position the equipment anywhere other than directly beneath it is strictly prohibited. • The placement site must be solid, flat, well-drained, and free of obstacles or protrusions. TERRA - User manual - English...
• After completing each wiring operation, conduct a thorough inspection to ensure the wiring is correct and secure. 6.2. Wiring Overview The wiring diagram for the external junction box is shown below: External junction box wiring schematic diagram TERRA - User manual - English...
Page 43
• Electrical connection work must only be performed by qualified electrical engineers. Ensure compliance with the ‘Safety Instructions’ outlined in this manual. • The company assumes no responsibility for personal injury or property damage resulting from non-compliance with these safety instructions. TERRA - User manual - English...
• The cables used must comply with local laws and regulations. • The cable colors shown in the illustrations in this manual are for reference only. Please select cables according to local cable standards. TERRA - User manual - English...
Page 45
The wiring component connection sequence is shown in the figure below. Serial # Name Serial # Name Copper row Spring pad Copper aluminum Flat pad transition terminal Bolt Connection sequence of copper and aluminum transition terminals TERRA - User manual - English...
4Ω. N OT I CE • The grounding method must comply with the standards and regulations of the installation site. • “The grounding resistance must meet the relevant local standards and regulations TERRA - User manual - English...
Page 48
• When paralleling, ensure there are no more than 2 hosts. • When operating parallel machines, verify that the device addresses Duplicate ID are not duplicated. Air conditioner not cooling • Check if the air conditioner switch is in the ‘off’ position. TERRA - User manual - English...
Page 50
This activates the release of the fire extinguishing medium into the protected area, effectively detecting and extinguishing the fire automatically. automatics pray Fire detection Cabinet temperature tubebreaks 170°C [ 370°F] automatically Feedback signal to LCDc ontrol panel TERRA - User manual - English...
Page 52
Lightning protection equipment Check whether lightning protection equipment and fuses are properly and fuses tightened. Corrosion Check for any oxidation or rust inside the product. TERRA - User manual - English...
Page 53
• Check the operating status of the fan. • Ensure that the fan is not blocked. • Listen for any abnormal noise while the fan is running. Screws • Check for any loose or missing screws inside the product. TERRA - User manual - English...
Page 54
Situation 2: The surface is dirty, the topcoat is damaged, and the surface traces cannot be cleaned. Situation 3: The primer is damaged, exposing the substrate. Maintenance steps for Situation 1: Materials: • Rag • Water • Alcohol or another non-abrasive cleaner TERRA - User manual - English...
Page 55
1. Use sandpaper to polish any raised or scratched areas of the surface paint to ensure a smooth finish. 2. Use a rag dipped in water or 97% alcohol to clean the damaged area and remove any surface stains. TERRA - User manual - English...
Page 56
1. Use sandpaper to polish the damaged areas of the paint, removing surface rust and burrs to ensure a smooth surface. 2. Clean the damaged area with a rag dipped in water or 97% alcohol to remove surface stains and dust. TERRA - User manual - English...
The following outlines the recommended maintenance cycle. However, the actual maintenance cycle should be adjusted based on the specific installation environment of the product. Factors such as power station size, installation location, and local environmental conditions will influence the required maintenance TERRA - User manual - English...
Page 58
• Inspect the box for any damage, paint peeling, oxidation, or other issues. • Check for the presence of foreign objects, dust, dirt, or condensation inside the battery cluster. TERRA - User manual - English...
6 months, maintaining the system’s SOC between 50% and 80%. The SOC must remain consistent after recharging. • Before using a long-term unused system for the first time, fully charge it at least TERRA - User manual - English...
Page 60
• Improper operation may result in serious personal injury or property damage. • The correct tools and protective equipment must be used when handling batteries. • Battery maintenance must only be performed by individuals with battery expertise and proper safety training. TERRA - User manual - English...
4~4.8 60~70 119~140 10.2. Quality Assurance If a product fails during the warranty period, Hybrid Power Solutions Inc. (hereinafter referred to as “the Company”) will repair or replace the product free of charge, provided the following conditions are met: Evidence During the warranty period, customers must present the invoice and date of purchase for the product.
• Brief description of the fault 10.4. Contact Details Hybrid Power Solutions Inc. 288 Judson St Unit #5, Toronto, ON M8Z 5T6 Canada Technical Support: +1 (289) 633-5055 Sales: +1 (866) 549-2743 E-Mail: Info@hybridps.ca Website: hybridps.ca TERRA - User manual - English...
Need help?
Do you have a question about the TERRA and is the answer not in the manual?
Questions and answers