Summary of Contents for Stern Weber S200

  • Page 1 97050618 Rev.003 06/2015...
  • Page 3 9.1. Instrument maintenance ........... 67 ( only model S220 TR CONTINENTAL HYBRID ) .... 15 9.2. Draining condensate (excluding the model S200 Cart) ..67 9.3. Cleaning the surgical suction fi lter ........68 Dental chair operation Dental chair operation .............
  • Page 4 WARNING! (only for the American and Canadian markets) The S200 series dental units and the relative accessories are intended for dental treatment, providing the dentist with a user interface to control functioning of the dental chair and all the connected instruments. The dental unit supplies air and water, and a suction and electrical energy system allows the dentist to intuitively control all the patient treatment procedures normally performed in a dentist’s surgery.
  • Page 5 S200 / S220 TR - OPERATING INSTRUCTION 1.2.1. Classifi cation • MEDICAL DEVICES classifi cation Classifi cation of the dental unit in accordance with the indications given in annex IX of directive 93/42/EEC and subsequent changes: Class IIa • ELECTRICAL MEDICAL EQUIPMENT classifi cation Classifi...
  • Page 6 If the device is modifi ed, appropriate examinations and tests need to be conducted in order to ensure continued safe use. • The technician not authorized by STERN WEBER who alters the product replacing parts or components with ones different from those used by the manufacturer shall assume liabilities in an identical manner as the manufacturer.
  • Page 7 S200 / S220 TR - OPERATING INSTRUCTION 1.4. Cleaning and disinfecting Cleaning is the fi rst step of any disinfecting process. Physically scrubbing with detergents and surface-active substances and rinsing with water removes a considerable amount of micro organisms. If a surface is not clean fi rst, the disinfecting process cannot be successful. If a surface cannot be adequately cleaned, it should be protected with barriers.
  • Page 8 S200 / S220 TR - OPERATING INSTRUCTION 1.5. Sterilization. Each instrument is supplied NOT STERILE and must be sterilized in a steam autoclave (max 135°C) before use, avoiding any form of chemical sterilization. Sterilization must be performed using suitable packaging materials checked during the sterilization process validation.
  • Page 9 S200 / S220 TR - OPERATING INSTRUCTION Description of the equipment 2.1. Nameplate Dental units model: Dental units model: S200 CONTINENTAL S200 INTERNATIONAL The nameplate is found on the arm between the dental chair and hydro- group. Data given on plate: •...
  • Page 10 - OPERATING INSTRUCTION 2.2. Dental units The dental units of the S200 series come in the following models: Model S200 CONTINENTAL Dentist’s instrument board in CONTINENTAL version (the instruments are retrieved by means of a spring arm system) applied on a double arm, of which one is articulated and self-balanced.
  • Page 11 S200 / S220 TR - OPERATING INSTRUCTION The dental units of the S220 series come in the following models: The dental units of the S220 series come in the following models: Model S220 TR CONTINENTAL and S220 TR J CONTINENTAL.
  • Page 12 S200 / S220 TR - OPERATING INSTRUCTION Model S220 TR CART Model S220 TR CART Dentist’s instrument board in INTERNATIONAL version (the Dentist’s instrument board in INTERNATIONAL version (the instruments are vertically inserted in their seats) applied on instruments are vertically inserted in their seats) applied on a height-adjustable trolley.
  • Page 13 WARNING: FOOT CRUSHING HAZARD Pay attention to the patient and the staff during dental chair descent. 2.4. Warnings for models S200 CART, S220 TR CART and S220 TR SINGLE CART WARNING! While moving the cart, pay attention to steps and/or horizontal obsta-...
  • Page 14 S200 / S220 TR - OPERATING INSTRUCTION 3. Turning on the dental operatory Dental units model: Dental units model: S200 CONTINENTAL S200 INTERNATIONAL S200 CART Press the main switch ( f1 ) on the dental chair casing and check on the control console that: •...
  • Page 15 S200 / S220 TR - OPERATING INSTRUCTION 3.1. 3.1. Inverting the operating unit confi guration for left-handed ope- Inverting the operating unit confi guration for left-handed ope- rators rators ( only model S220 TR CONTINENTAL HYBRID ) ( only model S220 TR CONTINENTAL HYBRID ) To invert the confi...
  • Page 16 S200 / S220 TR - OPERATING INSTRUCTION 4.1. Safety devices Dental units model: Dental units model: S200 CONTINENTAL S200 INTERNATIONAL S200 CART • The fl oor box is equipped with a device ( l ) that immediately stops the dental chair from moving down in the presence of an obstacle and auto- matically lifts it up to free the obstacle.
  • Page 17 S200 / S220 TR - OPERATING INSTRUCTION 4.2. Emergency devices WARNING! Use the devices below when movement of the equipment needs to be blocked: • Dental chair control buttons ( a ) or ( c ). Pressing any dental chair button blocks all movements.
  • Page 18 S200 / S220 TR - OPERATING INSTRUCTION 4.4. Adjustable armrest (optional) Pushing down the adjustable armrest Turn the adjustable armrest clockwise to move it down so that the patient can more easily get on and off the chair. Taking off the adjustable armrest.
  • Page 19 fi rst need to press the brake release button ( NOTE for S200 CART and S220 TR CART models: to adjust the height of the dentist’s instrument board, you fi rst need to press the...
  • Page 20 S200 / S220 TR - OPERATING INSTRUCTION Console unit position inversion Console unit position inversion ( only for model S220 TR CONTINENTAL HYBRID ). ( only for model S220 TR CONTINENTAL HYBRID ). WARNING! BEFORE CARRYING OUT THIS OPERATION, TURN OFF THE DENTAL UNIT.
  • Page 21 S200 / S220 TR - OPERATING INSTRUCTION Removable instrument cords. All the instruments have removable cords to ease cleaning. NOTE for CONTINENTAL version dentist’s instrument boards: NOTE for CONTINENTAL version dentist’s instrument boards: to remove the tubings you fi rst need to remove the instrument holder and to remove the tubings you fi...
  • Page 22 S200 / S220 TR - OPERATING INSTRUCTION 5.1. Doctor’s control console The pushbutton panels of the S200 and S220 TR series dental units are the following: Console with numerical display: S200 CONTINENTAL Console with LCD display: S200 CONTINENTAL S220 TR CONTINENTAL...
  • Page 23 S200 / S220 TR - OPERATING INSTRUCTION Negatoscope on/off button on console (only console with numerical display) Chair seat up and set position "1” button (only console with nu- merical display) Chair back up and set position "2” button (only console with nu- merical display) Chair seat down and set position "3”...
  • Page 24 S200 / S220 TR - OPERATING INSTRUCTION 5.1.1. Setting the dental chair "automatic return” and "rinse position” • Bring the dental chair into the desired position with the manual movements buttons. • Hold button “SAVE” for at least 2 seconds to activate memory mode.
  • Page 25 S200 / S220 TR - OPERATING INSTRUCTION 5.1.5. Button to reduce the operating lamp brightness (only console with LCD display). This button allows reducing the operating lamp brightness to a minimum. 5.2. Foot control 3 types of foot controls are available: "Multifunction”...
  • Page 26 S200 / S220 TR - OPERATING INSTRUCTION Left-hand button operation ( 4 ). • Key held down (at least 2 seconds) with the instrument removed: Chip-air operation: delivers air to the turbine or micromotor. Air is delivered by pressing the button. Air is no longer blown when the button is released.
  • Page 27 S200 / S220 TR - OPERATING INSTRUCTION 5.2.2. "Push-pedal” foot control Description of the parts Handle. Control pedal. Dental chair movements. Chip-air/patient rinsing position control. Water Clean System/Automatic dental chair return control. Spray operation LED. Battery charge LED (wireless version only).
  • Page 28 S200 / S220 TR - OPERATING INSTRUCTION Right-hand button operation ( 5 ). Operation: • Holding down the button for at least 2 seconds with the instruments in rest position: Activation of the “Automatic dental chair return” program. NOTE: this function is NOT active in the S220 TR SINGLE HYDRO UNIT models.
  • Page 29 S200 / S220 TR - OPERATING INSTRUCTION Dental chair movement joystick operation ( 3 ). Controlla i seguenti movimenti: • Chair seat up • Chair back up • Chair seat down • Chair back down To stop movement, release the button.
  • Page 30 S200 / S220 TR - OPERATING INSTRUCTION 5.2.4. Wireless foot control The "multifunction" and "pressure" foot control can also be supplied in wireless version. The wireless foot control contains a ZIGBEE transmitter module (module certifi ed for Europe, Canada and the USA).
  • Page 31 S200 / S220 TR - OPERATING INSTRUCTION Recharging the battery. When the batteries in the WIRELESS foot control need to be recharged, operate as follows: • Open the protective cap of the connector on the rear of the foot control and connect the recharging cable.
  • Page 32 S200 / S220 TR - OPERATING INSTRUCTION 5.3. Syringe Description of the instrument Nozzle b Handpiece Syringe release button d Air button Water button Hot/cold selector (only for 6-function syringes) g Hot/cold indicator light (only for 6-function syringes) Technical charachteristics.
  • Page 33 S200 / S220 TR - OPERATING INSTRUCTION 5.4. Turbine Connecting the handpiece and changing the chuck. Refer to the specifi c instructions furnished with the handpiece. Use. WARNING! Read the instructions for use of the various turbines. • Operating time: work 5 min., rest 5 min.
  • Page 34 S200 / S220 TR - OPERATING INSTRUCTION 5.5. Micromotor Coupling the handpieces and changing the chuck. Refer to the specifi c instructions furnished with the micromotor and various handpieces. Use. WARNING! Also read the instructions for use of the various motors.
  • Page 35 S200 / S220 TR - OPERATING INSTRUCTION Removable cord The turbine has a removable cord to ease cleaning (see paragraph 5.). Cleaning and care. Refer to the specifi c instructions furnished with the instrument. It is recommended to use Daily Oil (CEFLA S.C.) for lubrication.
  • Page 36 S200 / S220 TR - OPERATING INSTRUCTION 5.6. Scaler Connecting the handpiece and inserts. Refer to the specifi c instructions furnished with the handpiece. WARNING! Before attempting to connect the handpiece, make certain the con- tacts are perfectly dry. Blow air from the syringe, if necessary, to dry.
  • Page 37 S200 / S220 TR - OPERATING INSTRUCTION Removable cord. The scaler has a removable cord to ease cleaning (see paragraph 5.). Cleaning and care. Refer to the specifi c instructions furnished with the instrument. WARNING! • Do not soak the handpiece in liquid disinfectants or detergents.
  • Page 38 S200 / S220 TR - OPERATING INSTRUCTION 5.7. T LED curing light (not available for the American and Canadian markets) Technical specifi cations. Supply voltage: 24-36 VDC Max. power absorbed: 6 VA Light source: 1 5W LED Wavelength: 430-490 nm Acoustic signals: at cycle start, every 5 seconds, and at cycle end Type of operation : intermittent (3 consecutive cycles - 60 sec.
  • Page 39 S200 / S220 TR - OPERATING INSTRUCTION Operation. WARNING! The instrument is supplied non-sterile. Before use, disinfect the lamp grip. The optical fi bre and the eye pro- tection can be sterilized in a steam autoclave at 135°C. • Put the fi ber optic ( c ) in its housing until it clicks.
  • Page 40 S200 / S220 TR - OPERATING INSTRUCTION Safety guidelines WARNING! • The LED is a Class 2 light source in accordance with IEC 62471. DO NOT FIX THE BEAM. The light emitted may cause eye damage in the event of direct radiation without eye protection.
  • Page 41 S200 / S220 TR - OPERATING INSTRUCTION 5.8. C-U2 dental camera The C-U2 dental camera system, complete with an extremely lightweight ergonomic handpiece, is specially designed for simple and well-conceived usability in examining the oral cavity. Auto-exposure and fi xed focus features provide easy operation. This system is designed to allow the dentist to more effi ciently show and explain to patients all oral conditions and reasons for planned treatment.
  • Page 42 S200 / S220 TR - OPERATING INSTRUCTION • FREEZE function. Handpiece C-U2 is equipped with a touch-sensitive button ( g ). Tap this button or actuate the foot control to freeze the image of interest. Tap this button again (or actuate the foot control) to unlock the frozen image.
  • Page 43 S200 / S220 TR - OPERATING INSTRUCTION MyRay iCapture This program allows the C-U2 camera to be set up when it is connected to a PC/WORKSTATION. For a full description on how the MyRay iCapture program works, refer to the instructions, in electronic format, supplied with the C-U2 handpiece.
  • Page 44 S200 / S220 TR - OPERATING INSTRUCTION 5.9. ZEN-Xi integrated sensor Integrated sensor ZEN-Xi is a medical device employed to acquire intraoral x-rays in an electronic format with a Personal Computer interface device. When used together with dental practice management software, the x-ray pictures can be saved in the patient's folder and viewed on the desktop pc monitor at a later time.
  • Page 45 S200 / S220 TR - OPERATING INSTRUCTION 6. Assistant’s board operation Dental units model: S200 CONTINENTAL S200 INTERNATIONAL There are three types of assistant's board: Assistant's board type "1A". Main features: • The assistant's board ( a ) is connected to the hydro unit ( b ) by means of only one articulated arm ( o ) that allows positioning it in the most comfortable position for the operator.
  • Page 46 S200 / S220 TR - OPERATING INSTRUCTION Dental units model: Dental units model: S220 TR S220 TR CONTINENTAL HYBRID CONTINENTAL HYBRID Caratteristiche principali: • The module ( a ) is connected to the dental chair ( m ) by means of 3 arti- culated arms that allows positioning it in the most comfortable area for the operator.
  • Page 47 S200 / S220 TR - OPERATING INSTRUCTION 6.2. Syringe on assistant’s board For detailed information regarding operation of this instrument see para- graph 5.3. 6.3. Curing lamp on assistant’s board For detailed information regarding operation of this instrument see para- graph 5.7.
  • Page 48 S200 / S220 TR - OPERATING INSTRUCTION 6.5. Suction tubes Suction starts by taking the tube off the board. To adjust suction, use the slider ( a ) located on the tube handpiece. NOTE: when the tube is put back in place, suction stops approxi- mately 2 seconds later.
  • Page 49 S200 / S220 TR - OPERATING INSTRUCTION 6.7. 6.7. Hydraulic saliva ejector The hydraulic saliva ejector starts running When the tube is removed from The hydraulic saliva ejector starts running When the tube is removed from the support. the support.
  • Page 50 S200 / S220 TR - OPERATING INSTRUCTION Hydrogroup operation 7.1. Fill cup and bowlhiere The bowl can freely turn on the hydro unit by 305°; the movement can be manual by acting directly on the bowl or motor-driven (optional). The bowl and water to cup spout can be removed to ease cleaning.
  • Page 51 S200 / S220 TR - OPERATING INSTRUCTION Adjusting the amount of water used to fi ll the cup. • Turn on the operating unit holding down the Cup Water Delivery button on the assistant’s board. NOTE: 1 intermittent BEEP signals saving is in progress.
  • Page 52 S200 / S220 TR - OPERATING INSTRUCTION Taking off the bowl fi lter and rinse spout. • Pull up the spout ( l ) and take it off. • Pull up the fi lter ( q ) and its cover ( p ) to remove them.
  • Page 53 S200 / S220 TR - OPERATING INSTRUCTION 7.2. SANASPRAY /S System Description of the system. The SANASPRAY /S system is also equipped with a tank ( a ) located under the hydro unit and suitable to contain distilled water. The tank has a total capacity of 1.8 litres.
  • Page 54 S200 / S220 TR - OPERATING INSTRUCTION 7.2.1. Manual SANASPRAY system Valid only for the following models: S200 CART, S220 TR SINGLE HYDRO UNIT and S220 TR SINGLE CART. Description of the system. The system is equipped with a tank ( a ) suitable for distilled water.
  • Page 55 S200 / S220 TR - OPERATING INSTRUCTION 7.2.2. Disinfection cycle with oxygenated water With the SANASPRAY system, you can execute a manual disinfection cycle of all the water ducts of all the instruments on the dentist’s instrument board and the syringe on the assistant’s board using oxygenated water (hydrogen peroxide).
  • Page 56 S200 / S220 TR - OPERATING INSTRUCTION 7.3. WHE (Water Hygienization Equipment) system The WHE system assures safe separation (physically) of the dental unit water supply system from the public water mains thanks to a water free-fall section ( in compliance with EN 1717 ).
  • Page 57 S200 / S220 TR - OPERATING INSTRUCTION Error signalling. Console with numerical display: If the system detects a malfunction, 2 BEEPS are provided. The system shuts down and the operatory unit does not deliver water. In these cases, fi rst of all verify water and air are correctly supplied to the operatory unit.
  • Page 58 S200 / S220 TR - OPERATING INSTRUCTION 7.4. BIOSTER /S disinfection system (only console with LCD display) The BIOSTER /S system allows running a disinfection cycle of the water ducts of all the instruments on the dentist’s instrument board, of a dynamic instrument on the assistant's board and of the cup water delivery ducts.
  • Page 59 S200 / S220 TR - OPERATING INSTRUCTION WARNING! • After disinfection, make sure that you close the tank containing the disinfectant (exposed to air, it loses its effectiveness). • It is advisable to run at least one disinfection cycle a day, preferably at the end of the working day.
  • Page 60 S200 / S220 TR - OPERATING INSTRUCTION Execution of the FLUSHING cycle. • Start the fl ushing cycle by pressing the button on the dentist’s console a second time. 1 beep is emitted to confi rm the start of the fl ushing cycle.
  • Page 61 The system comes with a tank ( c ) that contains the liquid disinfectant and two fi ttings ( d ) used to wash the suction tubes. The detergent liquid tank has a total capacity of 250 cc (S200 series) or 500 cc (S220 TR series).
  • Page 62 S200 / S220 TR - OPERATING INSTRUCTION 8. Accessories 8.1. Operating lamp The operating lamp comes in 3 models: Lamp with halogen light source, model VENUS. Lamp with halogen light source, model VENUS. The instructions for use and maintenance of the halogen lamp model...
  • Page 63 S200 / S220 TR - OPERATING INSTRUCTION Adjusting the luminous intensity. Turn the knob (e): • Clockwise to increase the luminous intensity. • Anticlockwise to reduce the luminous intensity. NOTE for lamps with NO TOUCH sensor: You can also adjust the luminous intensity by keeping your hand still on the sensor ( k ) (sen- sitivity range 5 cm).
  • Page 64 S200 / S220 TR - OPERATING INSTRUCTION 8.1.2. Operating lamp Operating lamp model model VENUS VENUS e e Technical specifi cations. Technical specifi cations. • Operation: continuous. • Operation: continuous. • • Power supply voltage: Power supply voltage: 12 V~ 50/60 Hz.
  • Page 65 S200 / S220 TR - OPERATING INSTRUCTION Cleaning and disinfection WARNING! Carry out these operations with the lamp off and after letting it cool down. For cleaning and disinfection, use soft, non-abrasive disposable paper (avoid using recycled paper) or sterile gauze.
  • Page 66 S200 / S220 TR - OPERATING INSTRUCTION 8.2. Monitor on lamp pole The instructions for use and maintenance of the monitor are included with the dental unit. 8.3. Negatoscope for panoramas An x-ray fi lm viewer for panoramic x-rays can be mounted on all INTER- NATIONAL version instrument boards.
  • Page 67 Maintenance instructions for the instruments are enclosed with each instrument. WARNING! Maintenance of the instruments should be carried out with the equipment shut off. 9.2. Draining condensate (excluding the model S200 Cart) This operation should be done daily before starting work. Operate as follows: S200 series dental units •...
  • Page 68 S200 / S220 TR - OPERATING INSTRUCTION 9.3. Cleaning the surgical suction fi lter This operation should be done daily at the end of work. WARNING! Always wear gloves to prevent contact with infected material when cleaning the suction fi lter.
  • Page 69 S200 / S220 TR - OPERATING INSTRUCTION 9.5. CATTANI surgical separator At the end of each surgical procedure. • Execute an automatic fl ushing cycle or aspirate about ½ litre of sanitizing solution with each of the cannulas used. • Sterilize the cannula holder terminals in steam autoclave (see paragraph 1.5.).
  • Page 70 When disposing one-time use containers full of amalgam, observe current local and national laws. 9.10. Dental chair The dental chair does not require any particular maintenance. It is nevertheless advisable to once a year have an authorised STERN WEBER technician check overall functioning.
  • Page 71 S200 / S220 TR - OPERATING INSTRUCTION Error messages displayed on the console (only console with LCD display) M = Message C = Cause R = Remedy M: “E053” C: The level of disinfectant liquid in the relative tank has dropped to below minimum.
  • Page 72 S200 / S220 TR - OPERATING INSTRUCTION 11. Specifi cations Specifi cations 97042045 S200 Water delivery rate: 10 l/min S220 TR 97042055 S220 TR J Installation plan: Water consumption 2 l/min. S220 TR CART S220 TR J CART 97042056 S220 TR...
  • Page 73 S200 / S220 TR - OPERATING INSTRUCTION 11.1. S200 CONTINENTAL dimensional characteristics 2 460...
  • Page 74 S200 / S220 TR - OPERATING INSTRUCTION 11.2. S200 INTERNATIONAL dimensional characteristics...
  • Page 75 S200 / S220 TR - OPERATING INSTRUCTION 11.3. S200 CART dimensional characteristics...
  • Page 76 S200 / S220 TR - OPERATING INSTRUCTION 11.4. Dimensional characteristics S220 TR CONTINENTAL / S220 TR J CONTINENTAL...
  • Page 77 S200 / S220 TR - OPERATING INSTRUCTION 11.5. Dimensional characteristics S220 TR INTERNATIONAL / S220 TR J INTERNATIONAL...
  • Page 78 S200 / S220 TR - OPERATING INSTRUCTION 11.6. Dimensional characteristics S220 TR SIDE DELIVERY / S220 TR J SIDE DELIVERY...
  • Page 79 S200 / S220 TR - OPERATING INSTRUCTION 11.7. Dimensional characteristics S220 TR CART / S220 TR J CART...
  • Page 80 S200 / S220 TR - OPERATING INSTRUCTION 11.8. Dimensional characteristics S220 TR SINGLE CART / S220 TR J SINGLE CART...
  • Page 81 S200 / S220 TR - OPERATING INSTRUCTION 11.9. Dimensional characteristics S220 TR SINGLE HYDROGROUP / S220 TR J SINGLE HYDROGROUP...
  • Page 82 S200 / S220 TR - OPERATING INSTRUCTION 11.10. Dimensional characteristics S220 TR CONTINENTAL HYBRID 11.10. Dimensional characteristics S220 TR CONTINENTAL HYBRID...
  • Page 83 S200 / S220 TR - OPERATING INSTRUCTION 12. Dental operatory maintenance plan 12. Dental operatory maintenance plan WHEN PART SEE PARAGRAPH Before starting work. Drain condensate. See paragraph 9.2 See documentation enclosed Contra angle handpiece. Sterilize or disinfect the outside.