Supported Firmware Versions: This manual supports features and functions of firmware releases starting at Version 3.1.2, Build 4. Overall Operation: The EB1s Series of power supplies provide filtered and regulated AC output power of proper voltage and current values to operate amplifiers, nodes and other active devices in CATV and broadband networks.
Page 10
Battery Test/Self Test: The EB1s can perform a timed battery test. The test mode forces the power supply into battery power/inverter mode. The test can be initiated locally through the front panel, remotely through the status monitoring interface, or auto- matically at a preset interval.
Plant Status Monitoring. These MIBs must be used with the user’s choice of Network Management Software (NMS) when interfacing any transponders or additional equipment provisioned in the HFC plant. The EB1s transponders are compatible with a variety of NMS packages including Continuity and Cheetah XD. The following list is described in further detail and is available for download from www.scte.org.
Multilink representative immediately. Be sure to retain the original shipping carton and all packing material for the power supply until you are certain that warranty return will not be required.
Section 3: Front Panel Controls, Connections and Indicators The front panel of each EB1s Series power supply contains various connectors, all operator controls and indicators. These items are described as follows. Further details regarding use of controls and indicators may be found in the Startup and Operation section of this manual.
4.1 Preparation Installing and wiring any model within the EB1s Series power supplies into an enclosure may be accomplished by connecting input and output wiring to the appropriate connectors of the power supply. The AC input cord of the power supply mates with the standard receptacles of the region served.
LCD Screen Display: The LCD assembly chosen for the EB1s Series power supplies has been designed for use in a wide temperature range. As such, the characters displayed on the screen should be visible under nearly all temperature conditions.
Menu, or, when a compatible transponder is connected to the EB1s, this menu will be automatically enabled when a successful communication link is established between the transponder and the power supply. This protocol is currently supported only by the Electroline DOCSIS 2, 3.0, and 3.1 transponders with the appropriate firmware revision.
Section 9: Specifications 9.1 Electrical Specifications The various EB1s models cover a wide range of input voltages, input frequencies, battery voltages, output power, and output voltages. This table lists the electrical specifications of the available options. Nominal Output Output Battery...
Standard -40°C to +65°C @ 5% to 95% relative humidity, non-condensing. Elevation less than 3000 feet (de-rate 2°C per 1000' above 3000), installation in Multilink enclosure with ventilated Operating Environment battery tray, ensure proper cabinet ventilation and proper power supply position within the enclosure.
Page 53