Advertisement

Quick Links

X3 pro 15 web
Hardware and Installation
MAEN416
2025-03-21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X3 pro 15 web and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BeiJer X3 pro 15 web

  • Page 1 X3 pro 15 web Hardware and Installation MAEN416 2025-03-21...
  • Page 2 The information in this document is subject to change without notice and is provided as availa- ble at the time of publishing. Beijer Electronics AB, including all its group companies, reserves the right to change any information without updating this publication. Beijer Electronics AB, including all its group companies, assumes no responsibility for any errors that may appear in this document.
  • Page 3: Table Of Contents

    2.5. Disposal Requirements Under WEEE Regulations ..........8 3. Product Overview ..................9 3.1. Technical Data ..................9 3.1.1. X3 pro 15 web ................9 3.2. HMI Panel Drawings ................10 3.2.1. HMI Panel Outline ..............10 3.2.2. Connectors ................11 3.3.
  • Page 5: Introduction

    X3 web are industrial HMIs for HTML5 applications. Using the WebIQ software enables you to create web HMI applications through an intuitive drag-and-drop interface and straightforward configuration, with no coding required. X3 web allows you to run WebIQ on the device as a container application or as a browser application. Beijer Electronics, MAEN416 2025-03...
  • Page 6: Naming Convention

    4 000 tags WebIQ license. NOTE Not all combinations are available. 1.4. Operating Systems and Software Product Operating System Software included iX Runtime X3 web Linux WebIQ bundle version available 1.5. References Name X3 web Configuration and Operation WebIQ documentation 2025-03 Beijer Electronics, MAEN416...
  • Page 7: Safety Precautions

    • Only qualified personnel should perform the installation of the HMI panel. • Separate high voltage cables from signal and supply cables. • Prior to connecting the HMI panel to the power outlet, verify that the voltage and polarity of the power source are correct. Beijer Electronics, MAEN416 2025-03...
  • Page 8: Hazardous Materials

    (EEE), please contact your dealer or supplier for further information. For disposal in countries outside of the European Union: If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal. 2025-03 Beijer Electronics, MAEN416...
  • Page 9: Product Overview

    Product Overview 3. Product Overview 3.1. Technical Data 3.1.1. X3 pro 15 web Front panel, W × H × D 410 × 286 × 8 mm Cutout dimensions, W × H 394 × 270 mm Mounting depth 66 mm Standalone mounting VESA 75 × 75...
  • Page 10: Hmi Panel Drawings

    1 g, according to IEC 60068-2-6, Test Fc Mechanical shock 15 g, half-sine, 11 ms according to IEC60068-2-27 Approvals and certifications CE/FCC/KCC 3.2. HMI Panel Drawings 3.2.1. HMI Panel Outline NOTE Minimum thickness for the front plate is 2.0 mm. 2025-03 Beijer Electronics, MAEN416...
  • Page 11: Connectors

    USB 3.0 Host, max output current 900 mA Power supply 3-pin screw connector, +24 V DC (18-32 V DC) Ground screw Screw to connect functional ground Power supply pin assignment Description Vin+ (main input supply voltage) Vin- (power ground) FG (frame ground) Beijer Electronics, MAEN416 2025-03...
  • Page 12: Chemical Resistance

    Petroleum spirit Ajax / Vim in solution Downy / Lenor Phosphoric acid (<30%) Alkalicarbonate solution Ethanol Potassium ferricyanide Ammonia (<40%) Glycerine Potassium hydroxide (<30%) Acetic acid (<50%) Glycol Pure Turpentine Ariel powder in solution Gumption SBP 60/95 2025-03 Beijer Electronics, MAEN416...
  • Page 13: Touch Screen Surface

    Toluene 5 hours Touch Screen Protector To safeguard the touch screen from damage in harsh environments and outdoor exposure, it is advisable to use a protective film. This optional part can be ordered from Beijer Electronics. Beijer Electronics, MAEN416 2025-03...
  • Page 14: Configuration And Operation

    The USB port(s) also support connecting a keyboard and mouse. 4.1.4. External Storage Media IMPORTANT Beijer Electronics recommend using industrial grade SDHC or SDXC cards. An external memory card (SD, SDHC or SDXC, with FAT16, FAT32 or exFAT file systems) can be inserted (option, sold separately).
  • Page 15 • Use the default setting “Log changes only” in the property setting of the Data logger. • Keep the log size to a minimum, as few rows as needed. • Avoid extensive file writing when controlling storage via script. Beijer Electronics, MAEN416 2025-03...
  • Page 16: Mounting And Installation

    Place the HMI panel on a stable surface during installation. Dropping or allowing the panel to fall may cause damage. Create the cutout for the HMI panel based on the following dimensions: 394 × 270 mm 2025-03 Beijer Electronics, MAEN416...
  • Page 17 flip out and tighten against the metal sheet as shown. Tighten the screws to a torque of 0.5 - 0.9 Nm. In cases where the front panel seal (IP54 or greater, NEMA-4X) is critical, use a torque wrench to ensure all screws are tightened to the specified torque. Beijer Electronics, MAEN416 2025-03...
  • Page 18: Method 2: Mount The Hmi Panel On A Vesa Mount Or Other Flat Surface

    Place the HMI panel on a stable surface during installation. Dropping or allowing the panel to fall may cause damage. Install the unit on a VESA compliant mounting bracket, or drill the correct hole pattern according to the following drawing, 2025-03 Beijer Electronics, MAEN416...
  • Page 19 Ø 4.5 ± 0.5 mm Fasten the HMI panel according to the following specifications. Measurement Value Screw thread type M4 × 0.7 mm Screw thread depth Max. 7 mm Required engagement Min. 5 mm Torque Max. 3.5 Nm Beijer Electronics, MAEN416 2025-03...
  • Page 20: Controller Cabling Requirements

    5.3.1. Ground the HMI Panel The mounting clamps, (A) in the drawing below, do not provide a secure grounding connection between the panel and the device cabinet. The following section describes how to ground the HMI panel correctly. 2025-03 Beijer Electronics, MAEN416...
  • Page 21 Twist the cables onto the 24 V DC feed (E). • 2 turns around the ferrite core (F) provide 4 times the suppression of 1 turn. • 3 turns around the ferrite core (F) provide 9 times the suppression of 1 turn. Beijer Electronics, MAEN416 2025-03...
  • Page 22: Grounding And Shielding Options For Ethernet Cabling

    5.3.3. Improve EMC Protection To improve EMC protection, follow the instructions below: Cable recommendations • Use original cabling from Beijer Electronics primarily. • Use shielded cables for RS-232 communication. • Use twisted pair and shielded cabling for RS-422 and RS-485. • Use the cabling intended for the bus type; Ethernet, Profibus, CC-Link, CAN, DeviceNet etc.
  • Page 23: Ambient Temperature

    If the cables need to be crossed, cross them at 90° only. Avoid combining the cabling for stronger 24 V DC outputs with the communication cabling. 5.3.4. Ambient Temperature IMPORTANT Ensure that the temperature inside the cabinet does not exceed the maximum ambient operating temperature specified. Beijer Electronics, MAEN416 2025-03...
  • Page 24: Install A Fan

    • Do not mount the fan at the top, where it will draw in warm air. This can shorten the fan's lifespan. 5.3.5. Power Supply Safety WARNING Ensure that the power supply meets the current safety standards. 2025-03 Beijer Electronics, MAEN416...
  • Page 25 24 V unit to safely power all feeds, see section (C) in the drawing above. Grounding Connect the 0 V of the 24 V power supply to the ground, shown as (D) in the drawing above. This provides the following benefits: Beijer Electronics, MAEN416 2025-03...
  • Page 26: Galvanic Isolation

    External Units for Galvanic Isolation External units can enhance communication and provide galvanic isolation. However, this solution might introduce other issues when interfacing with other devices. It is essential to carefully assess compatibility to avoid unforeseen problems. 2025-03 Beijer Electronics, MAEN416...
  • Page 27: Rs-485 Communication

    • Use the screensaver functionality. • Changing constantly between static and dynamic images. • Avoid excessive brightness differences between foreground and background elements. • Use colors with similar brightness. • Use complementary colors in follow-up images. Beijer Electronics, MAEN416 2025-03...
  • Page 28: Service And Maintenance

    Apply cleaning agent (alcohol, bleach, or glass cleaner) to a clean cloth. Make sure the cloth is well saturated. Do not spray the cleaning solution directly onto the display. Wipe the touch panel surface in a “Z” motion. 2025-03 Beijer Electronics, MAEN416...
  • Page 29: Air Bubbles In Touch Screen

    This is purely cosmetic and does not affect the functionality of the HMI panel. The appearance can occur under certain environmental conditions such as changes in temperature, humidity, or atmospheric pressure. 6.3. Replace the Battery The battery must be replaced by an authorized Beijer Electronics service center. Beijer Electronics, MAEN416 2025-03...
  • Page 30: Dismantling And Disposal

    7. Dismantling and Disposal • Recycle the HMI panel and parts of it according to local regulations. • The following components contain substances that might be hazardous to health and the environment: lithium battery, electrolytic capacitor, and display. 2025-03 Beijer Electronics, MAEN416...
  • Page 31 Head Office Beijer Electronics AB Box 426 201 24 Malmö, Sweden www.beijerelectronics.com / +46 40 358600...

Table of Contents