Amphenol PCB PIEZOTRONICS ICP 086D05 Installation And Operating Manual

Modal/impact/impulse hammer

Advertisement

Quick Links

Model 086D05
Modally Tuned® Impulse Hammer w/force sensor and tips, 0 to 5k lbf, 1 mV/lbf (0.23 mV/N)
Installation and Operating Manual
For assistance with the operation of this product,
contact the PCB Piezotronics, Inc.
Toll-free: 716-684-0001
24-hour SensorLine: 716-684-0001
Fax: 716-684-0987
E-mail: info@pcb.com
Web: www.pcb.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PCB PIEZOTRONICS ICP 086D05 and is the answer not in the manual?

Questions and answers

Summary of Contents for Amphenol PCB PIEZOTRONICS ICP 086D05

  • Page 1 Model 086D05 Modally Tuned® Impulse Hammer w/force sensor and tips, 0 to 5k lbf, 1 mV/lbf (0.23 mV/N) Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
  • Page 2: Repair And Maintenance

    Repair and Maintenance Returning Equipment If factory repair is required, our representatives will PCB guarantees Total Customer Satisfaction through its provide you with a Return Material Authorization (RMA) “Lifetime Warranty Plus” on all Platinum Stock Products number, which we use to reference any information you sold by PCB and through its limited warranties on all other have already provided and expedite the repair process.
  • Page 3 CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
  • Page 4 PCB工业监视和测量设备 - 中国RoHS2公布表 PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 有害物质 镉 汞 铅 (Pb) 六价铬 (Cr(VI)) 多溴联苯 (PBB) 多溴二苯醚 (PBDE) 部件名称 (Hg) (Cd) 住房 PCB板 电气连接器 压电晶体 环氧 铁氟龙 电子 厚膜基板 电线 电缆 塑料 焊接...
  • Page 5 Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
  • Page 6: Table Of Contents

    Installation and Operating Manual ® Modal / Impact / Impulse Hammer CONTENTS: Introduction ........1.0 Description ........2.0 Installation and Operation ..... 3.0 Testing .......... 4.0 Calibration ........5.0 Maintenance ........6.0 Precautions ........7.0 Warranty and Service ....8.0 INTRODUCTION ®...
  • Page 7 086E80 Family Impulse Hammer Response Curves 086E80 Family Frequency Response Curves Hard Tip Hard Tip (20 lbf nom.) (20 lbf pk) Vinyl Cover Vinyl Cover (1.3 lbf pk) (1.3 lbf nom.) 1000 10000 100000 Frequency (Hz) 086C01 Family Impulse Hammer Response Curve 086C01 Family Frequency Response Curves Hard Tip Hard Tip...
  • Page 8 086C02, C03, C04, C40 Family Impulse Hammer Response Curves 086C02, C03 & C04 Family Frequency Response Curves Hard Tip Hard Tip (80 lbf pk) (80 lbf nom.) Medium Tip Medium (80 lbf nom.) Soft Tip Soft Tip (20 lbf nom.) (80 lbf pk) (20 lbf pk) Medium Tip...
  • Page 10: Description

    Hammer model selection involves determining the size and mass of the hammer structure which will provide the force amplitude and frequency content required for proper excitation of the structure under test. Large, heavy structures like locomotive frames, tanks and bridges require an instrumented sledgehammer;...
  • Page 11: Testing

    TESTING Generally speaking, the impact tips affect the hammer impulse frequency content, and the extender affects the signal energy level. Frequency content and energy level are interrelated, so both will be affected by different hammer structures. Hammer velocity at impact will also affect both. In general, massive structures with lower stiffness require the use of the extender and soft impact tip to adequately excite low frequency resonances.
  • Page 12: Calibration

    When configuring your oscilloscope or data acquisition system, it is recommended that the input be set to DC coupled. This is because, in some cases, the time constant associated with the equipment’s AC ® coupling circuit is less then that of the impulse hammer and PCB ICP power units.
  • Page 13: Precautions

    PRECAUTIONS Although hammers are very rugged in construction, damage can result from misuse. When observed, the following precautions can ensure long life and accurate data. 1. Do not attempt to dismantle sensor element from hammer structure. All service should be performed at the factory.
  • Page 14 ICP® IMPACT HAMMER Model Number Revision: H ​ ​ 086D05 ECN #: 55566 OPTION AL VERSION S Performance EN GLISH Optional versions have identical specifications and accessories as listed for the standard model except Sensitivity(± 15 %) 1 mV/lbf 0.23 mV/N where noted below.
  • Page 15: Repair And Maintenance

    Repair and Maintenance Returning Equipment If factory repair is required, our representatives will PCB guarantees Total Customer Satisfaction through its provide you with a Return Material Authorization (RMA) “Lifetime Warranty Plus” on all Platinum Stock Products number, which we use to reference any information you sold by PCB and through its limited warranties on all other have already provided and expedite the repair process.
  • Page 16 CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
  • Page 17 PCB工业监视和测量设备 - 中国RoHS2公布表 PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 有害物质 镉 汞 铅 (Pb) 六价铬 (Cr(VI)) 多溴联苯 (PBB) 多溴二苯醚 (PBDE) 部件名称 (Hg) (Cd) 住房 PCB板 电气连接器 压电晶体 环氧 铁氟龙 电子 厚膜基板 电线 电缆 塑料 焊接...
  • Page 18 Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
  • Page 19 PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. RELEASED TO DRAFTING 55566 .94 - 1.03 [23.9 - 26.2] .67 - .70 [17.0 - 17.8] .18 - .25 [4.6 - 6.4] .82 - .86 [20.8 - 21.8]...
  • Page 20 Model 086D05 Modally Tuned® Impulse Hammer w/force sensor and tips, 0 to 5k lbf, 1 mV/lbf (0.23 mV/N) Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
  • Page 21 Repair and Maintenance Returning Equipment If factory repair is required, our representatives will PCB guarantees Total Customer Satisfaction through its provide you with a Return Material Authorization (RMA) “Lifetime Warranty Plus” on all Platinum Stock Products number, which we use to reference any information you sold by PCB and through its limited warranties on all other have already provided and expedite the repair process.
  • Page 22 CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
  • Page 23 PCB工业监视和测量设备 - 中国RoHS2公布表 PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 有害物质 镉 汞 铅 (Pb) 六价铬 (Cr(VI)) 多溴联苯 (PBB) 多溴二苯醚 (PBDE) 部件名称 (Hg) (Cd) 住房 PCB板 电气连接器 压电晶体 环氧 铁氟龙 电子 厚膜基板 电线 电缆 塑料 焊接...
  • Page 24 Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
  • Page 25 PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. UPDATED NOTES 55566 3.0 [77] SOFT IMPACT CAP (BLACK) 1.0 [25] HARD IMPACT CAP...

Table of Contents