ACIS immerstar Installation Instructions Manual

Alarm device for swimming pool

Advertisement

Quick Links

ALARM DEVICE
for swimming pool
Installation Instructions - User Manual
Read carefully and save for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the immerstar and is the answer not in the manual?

Questions and answers

Summary of Contents for ACIS immerstar

  • Page 1 ALARM DEVICE for swimming pool Installation Instructions - User Manual Read carefully and save for future reference.
  • Page 2 Accidents do not only happen to others! Be ready to act! In no case can ACIS be held liable for any fall or drowning of any person or animal. Use of the IMMERSTAR® device must not lessen your vigilance or substitute for active supervision of the pool and its surroundings.
  • Page 3: Table Of Contents

    Functional Test in the Pool: ..........page 9 Alkaline Batteries ..............page 10 Operation ................. page 10 Complete stop ................ page 11 Additional Information ............page 13 Safety Advice ................page 15 Page 3 Feb. 2017 Alarm device Immerstar® - Installation Instructions - User Manual...
  • Page 4: Presentation

    • The standard NFP 90-307-1:2009 relating to pool alarms specifies the detection of any fall within a maximum time of 12 seconds: therefore the IMMERSTAR® may not be situated more than 7 meters away from any potential fall site.
  • Page 5: Checking The Packaging And Contents

    IMMERSTAR® alarm (pool covering, cleaning robot,etc.). Ask your installer for advice. • The IMMERSTAR® alarm is not designed for free standing pools with soft walls, pools without a border, mirror pools, pools equipped with a gradually sloped access or pools equipped with a high rate of filtering (similar to that of a counter-current system).
  • Page 6: Checks Before First Use

    IMMERSTAR® is currently in its calibration phase bip bip bip 4 – After 3 seconds, IMMERSTAR® emits a series of BEEPS: IMMERSTAR® has switched over automatically into swimming mode 5 – The red LED blinks, signalling that the IMMERSTAR® is in swimming...
  • Page 7: Choice Of Installation

    ACIS. Choice of Installation In order to minimize the alarm’s response time in the event of a fall, the IMMERSTAR® device must be fastened at the middle of the longer edge of your pool and have the entire pool in direct line of sight.
  • Page 8: Installation On The Border

    The alarm must be installed switched off, with the cover removed. Position the alarm in such a way that the plunger tube is minimum 5 mm away from the edge of the border. The IMMERSTAR® alarm is designed to be fastened to rigid borders at least 100 mm wide.
  • Page 9: Functional Test In The Pool

    4. After 3 seconds, IMMERSTAR® emits a series of BEEPS: IMMERSTAR® has just switched over automatically to swimming mode. +/- 3 Seconds 5. The red LED LED blinks, signalling that the IMMERSTAR® is in bip bip bip swimming mode. 6. After less than 15 minutes, IMMERSTAR® emits a series of BEEPS: IMMERSTAR®...
  • Page 10: Alkaline Batteries

    (use the table of controls given on the last page of this document). Under normal operation, it is imperative to remove the key. So that people can swim in the pool, the IMMERSTAR® alarm must be in “swimming” mode, with the red LED blinking.
  • Page 11: Complete Stop

    If you have any problems, get in touch with your vendor immediately, or ACIS. *Warning : in accordance with regulation 2003-9 on pool safety, we remind you that this device “must be installed and fastened permanently, all year round”. In the event of drowning while your IMMERSTAR® is at Page 11 Feb.
  • Page 12 Warnings : FROST – Beware : Your IMMERSTAR® system will not function if there is water frost inside the sensor, or if the surface of the pool water is frozen. In case of doubt as to the solid or liquid state of the water inside the tube, carry out a functional alarm test.
  • Page 13: Additional Information

    It is essential to insist on active supervision by parents. Information Concerning the IMMERSTAR® Alarm The IMMERSTAR® alarm system is not a substitute for common sense or for individual responsibility. It is also not intended as a substitute for supervision by parents and/or responsible adults, who are still the essential factor for the protection of children (most notably those under 5 years of age).
  • Page 14: Safety Advice

    Switch off the counter-current mechanism when finished swimming in order to be able to reactivate “surveillance” mode. In no case may your vendor or the manufacturer of the IMMERSTAR® alarm be held liable for the drowning of a child, a dependent person, any adult or any animal.
  • Page 15 Memorize and put up the numbers of the emergency services near the pool. Numbers accessible from a landline Fire brigade Mobile emergency medical service Numbers accessible from all telephones: European emergency number Regional treatment centers for poisoning cases Page 15 Feb. 2017 Alarm device Immerstar® - Installation Instructions - User Manual...
  • Page 16 CONTROL PANEL Magnetic zone- Green indicator: Red indicator: surveillance mode swimming mode - FRANCE 15 rue des marais - 44310 ST PHILBERT DE GRAND LIEU...

Table of Contents