Advertisement

Quick Links

Assembly And operAting mAnuAl
GLASS LIFT S-ESAM 3.0 & 3.1
STATUS 09.2024
the fire of your life.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GLASS LIFT S-ESAM 3.0 and is the answer not in the manual?

Questions and answers

Summary of Contents for Spartherm GLASS LIFT S-ESAM 3.0

  • Page 1 Assembly And operAting mAnuAl GLASS LIFT S-ESAM 3.0 & 3.1 STATUS 09.2024 the fire of your life.
  • Page 2: Document Information

    Document information Assembly and operating manual for s-esAm 3.0 & 3.1 glass lifts. Symbol explanation for text 4 Action prompt the images show version 3.1 and use with the premium A-3rl-60h fireplace insert. • list the glass lift is referred to as the “unit” in this manual. the full 3 Check system including the fireplace insert, thermal storage medium, pipes and chimney is referred to as the “stove system”.
  • Page 3: Table Of Contents

    Table of contents Safety information 8. Disposal Intended use Disposing of the packaging Authorised target groups Disposing of the unit 1.2.1 Manufacturer 9. Appendix 1.2.2 Owner Accessories 1.2.3 Qualified personnel Standards and regulations 1.2.4 Users Declarations of conformity General safety information 2.
  • Page 4: Safety Information

    Safety information Safety information Authorised target groups Authorised target groups are divided into groups of people with different levels of authorisation. Intended use 1.2.1 Manufacturer the unit is an accessory for fireplace inserts produced by the manufacturer and the manufacturer’s agents have the the manufacturer and is used to open and close elevating following tasks: combustion chamber doors electrically.
  • Page 5: Users

    1.2.4 Users General safety information instructed users perform work during use, cleaning and . WARNING! servicing. requirements for instructed users: Danger due to non-adherence to the operating and • the users have been instructed in the safe and intended assembly instructions! use of the unit.
  • Page 6: Product Information

    Product information Product information Product overview 2.2 / 1 Functional principle Activating the handheld transmitter (A) prompts the control system (F) to send the corresponding command to the drive unit (J): • For opening, the drive motor pulls the pull rope onto a drum in the rope box on the drive unit.
  • Page 7: Protective Devices

    Protective devices Models • Automatic closing function. the combustion chamber door the unit is available for the following fireplace inserts: will be closed automatically in the following situations: • premium V-1V-87h • • After two minutes if left open. premium V-Fd-87h •...
  • Page 8: Assembly

    Assembly 5 We strongly recommend positioning the control system so Assembly that you will be able to hear acoustic signals and access the control system at any time. this is, for instance, required to read error codes, reset errors or execute emergency lowering. Safety information for assembly see the corresponding manual for details of safety distances .
  • Page 9: Connecting The Control System

    Connecting the control system 3.6 / 3 3.6 / 1 ” X .X „ S f t e ü r li ” X .X 1 ,0 is c k t r E le „ S r ie f t e z ie ü...
  • Page 10: Connecting Additional Systems (Optional)

    Assembly When connecting the unit for operation via the s-thermatik neo 3.6 / 5 combustion control, the unit must be connected to the “no” and “Com” pins of the “relAy2” or “relAy3” connection on the combustion control. the polarity is irrelevant. the chosen relay must be assigned the “sesAm”...
  • Page 11: Teaching In End Positions

    4 install the button for external reset in a suitable position, s-esAm 3.1 only guiding it out of the fireplace cover panel, or directly behind if the door does not make full contact with the seal in its bottom- the stove system. most position: 4 Adjust the lowering speed of the door.
  • Page 12: Checking The Installation

    Assembly Checking the installation 4 make sure that the unit’s components can be accessed at all times for maintenance purposes (e.g. via inspection ports fitted on site). 4 Check that power and electrical connection cables are not kinked, crushed, damaged or under tension. 4 ensure that the necessary protective devices are functional.
  • Page 13: Use

    Information on the operating principle • An open combustion chamber door will be closed automatically after two minutes for safety reasons. the closure will be signalled ten seconds in advance by two Safety information for use sounds from the control system. the combustion chamber door lowers slowly, including .
  • Page 14: Carrying Out Movements

    Carrying out movements the movement command is confirmed by a sound from the control system. the combustion chamber opens slowly at first . WARNING! so that the pressure can be equalised and nothing swirls up. the combustion chamber door then moves to its top end Risk of injury due to contact with hot surfaces! position.
  • Page 15: Managing Handheld Transmitters

    Managing handheld transmitters Connecting up a new handheld transmitter: 4 press and hold the red button (A). At least one handheld transmitter or an external command 4 then press and hold the button on the new handheld transmitter must be connected in order to operate the control transmitter (C) that you wish to connect.
  • Page 16: Cleaning

    Cleaning Cleaning the unit’s closing function will close an open combustion chamber door automatically after two minutes. to keep the combustion chamber door open permanently for cleaning: 4 open the closed combustion chamber door by hand. 4 make sure that the combustion chamber door cannot fall back down, e.g.
  • Page 17: Service Work

    Service work Maintenance measures the unit does not need any maintenance. individual components (e.g. handheld transmitter(s), motor unit) may require the following work: Safety information for service work . WARNING! 6.2.1 Replacing batteries Danger due to non-adherence to service work instructions! 6.2.1 / 1 incorrect servicing of the unit may lead to severe injuries.
  • Page 18: Replacing The Motor

    Service work 6.2.2 Replacing the motor 6.2.2 / 3 if the drive unit is faulty, the motor and rope drum can be replaced. the drive unit can be accessed through the inspection ports on the fireplace insert. 5 We recommend changing the whole drive unit. 6.2.2 / 1 4 push the arms on the clamping rollers outwards.
  • Page 19 6.2.2 / 5 6.2.2 / 7 4 loosen the three motor screws. 4 ensure that the rubber rollers engage precisely in the pulley. 4 pull the motor out of the rope box. to reinstall the motor, proceed in the reverse order. Watch out for the following when doing so: 6.2.2 / 6 4 ensure that the featherkeys are positioned correctly in the...
  • Page 20: Malfunction Repair

    Service work Malfunction repair Movement commands are not being carried out. • the handheld transmitter batteries are flat. possible malfunctions are described in the following section: 4 replace the batteries. 6 “6.2.1 replacing batteries” (page 17). What malfunction is occurring? •...
  • Page 21: Led Displays And Fault Codes

    ” X . X „ S i f t e ü r l 1 , 0 i s c k t r E l e r i e z i e LED displays and fault codes t r i e f n a s t e “Status”...
  • Page 22: Disassembly

    Disassembly Disassembly Disposal Safety information for disassembly Disposing of the packaging . WARNING! . ATTENTION! Danger due to non-adherence to disassembly instructions! Risk of environmental damage caused by improper disposal of the packaging! incorrect disassembly of the unit may lead to severe injuries. 4 do not dispose of the packaging with the normal household this chapter contains important information for safe disassembly of the unit.
  • Page 23: 9. Appendix

    • button for external reset. An eu declaration of conformity is available on the manufacturer’s website: 7 www.spartherm.com if required and for additional information (e.g. brochures, spare parts, price lists): 4 please contact the manufacturer or a specialist shop. 7 www.spartherm.com Standards and regulations relevant regulations –...
  • Page 24 SPECIALIST DEALERS www.facebook.com/spartherm www.instagram.com/spartherm www.youtube.com/sparthermgermany www.spartherm.com Spartherm Feuerungstechnik GmbH Maschweg 38 | 49324 Melle | GERMANY | Phone: +49 5422 9441-0...

This manual is also suitable for:

Glass lift s-esam 3.1

Table of Contents