FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr TABLE OF CONTENTS PAGE CHAP WARRANTY THE FRIGOMATIC 35 F FRIGOMATIC Mod. AV 35F - AH 35F FRIGOMATIC Mod. PARIS , ROMA, MADRID FRIGOMATIC Mod. CAPRI FRIGOMATIC Mod. "K 35F & K50F" FRIGOMATIC Mod. "W 35F & W 50F" ELECTRONIC CONTROLLER FOR FRIGOMATIC BD35F &...
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr WARRANTY The warranty card must be filled in by your supplier, stamped and signed by an Frigoboat authorized service station (see point E). You will need to show the warranty card when you want the unit under warranty to be repaired. The authorized service station will take a note of what has been done or of what was suggested on the back of the warranty card.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr CHAPTER 1 THE FRIGOMATIC 35F The "Frigomatic" unit consists of the following components: 1) The condensing unit, in one of configuration available: FRIGOMATIC PARIS - FRIGOMATIC ROMA - FRIGOMATIC MADRID - FRIGOMATIC CAPRI - FRIGOMATIC AV - FRIGOMATIC AH - FRIGOMATIC W - FRIGOMATIC K.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr 2.2 - INSTALLATION 2.2.A -FRIGOMATIC MODEL AV 35F The easiest way is to hang the unit on the bulkhead through which the air has to be blown. Use the template supplied to mark the position of the fixing screws (four will be sufficient) and the outline of the hole.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr preheated as a result of being drawn from, for instance, the engine room. CHAPTER 4 FRIGOMATIC MOD. CAPRI 35F It consists of the compressor, an aluminum-copper condenser, a dryer, a brushless fan with duct adaptor 120 mm, 1 service port and 2 quick connects for assembling the unit with the evaporator.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr D.- Fix the unit using the 4 holes in its base. Pay attention to leave enough space for the evaporator and keel cooler connections. 5.2 - KEEL COOLER The keel cooler exists in 2 versions: Standard and Ground plate. This last has the capability to act as a ground plate for electronic instruments.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr The pump we supply is self-priming. When installing it, make sure that there is a good intake strainer (120 Mesh). Frigoboat part number A091508. When all connections are completed, operate independently the water pump and make sure that: A.- You have no water leaks.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr BD 35F ) it must be used a stabilized mains adaptor E51305 which gives always 24V even if the battery supplies 12V. NOTICE 1: After the electronic unit is powered you could have a waiting time up to 30 seconds, before the compressor starts.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr drilled in your cabinet (consider also the passage of the capillary or thermostat cable). 8.3 - INSTALLATION The assistance of another person is very useful at this point. Unroll completely the evaporator pipe and arrange the two end couplings so that they will pass one after the other through the sequence of holes that you have prepared, the male coupling (IM) proceed the female coupling (IF).
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr the extension pipe as recommended for the evaporator pipe. The use of long extensions is slightly affecting the unit efficiency. 8.8 - THERMOSTAT CAPILLARY The evaporator is equipped with a small plate to be used to connect the tail of the thermostat capillary (See 8.5).
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr at its tip only as other colder contacts could affect the operational characteristics. We strongly suggest that the small fixing plate is easily accessible in order to make future maintenance easily. If necessary the plate can be swapped from one face to the other the evaporator reversing also the plastic nut.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr coupling to form a complete refrigeration system. IMPORTANT Under no circumstances run the Frigomatic compressor unless the two quick connects are fully joined. 11.1 COUPLING THE QUICK CONNECTS The quick connects on the condensing unit are fitted with brass plugs which have to be unscrewed at the very last moment before the two half couplings are brought together.
Page 14
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr and of good quality, with minimum power capacity of 20A (10 A for 24V supply). If you use a circuit breaker make sure that it doesn’t cause too much voltage drop at start. 12.2 - WIRE SIZE Measure the length the lead will have between the service control board and the electronic controller.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr 12.5.4 - Frigomatic K - Frigomatic W These models are supplied equipped with the device E51045 which permits to choose the compressor speed between 2,000 and 3,500 Rpm simply connecting the thermostat at C connection and the connection corresponding to the desired speed.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr CHAPTER 13 TROUBLE SHOOTING 13.1 - TEMPERATURE IS TOO LOW Chap. Cause Diagnosis and Remedy 13.1.1 Thermostat Turn the thermostat knob on a lower number. 13.1.2 Thermostat The unit runs continuosly without cycling : in spite of the thermostat position.
Page 17
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr 13.3 - COMPRESSOR DOESN'T RUN Chap. Cause Diagnosis and Remedy 13.3.1 You are to anxious, not Wait at least a minute without disconnecting, giving enough time to the the main switch and with the thermostat unit.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr 13.5 - THE COMPRESSOR RUNS - LOW EFFICIENCY Temperature in the fridge is too high - the evaporator is wet and it freezes partially, close to the capillary inlet. Chap. Cause Diagnosis and Remedy 13.5.1 The unit has a leak Stop the unit and call for service...
Page 19
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr 15.1.B - Low pressure gauge: we recommand to disconnect the low pressure gauge only when you have stopped the unit reaching a 0 pressure value in the suction side. 15.2 - SEEKING FOR A LEAK Before recharging the unit you must find and repair the leak.
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr period of time or/and remained open to the ambient for over 6 hours. The procedure we suggest is the following: A.- Remove the refrigerant dryer. B.- Install a new refrigerant dryer. C.- Connect the gauges and the vacum pump to high and low pressure service valves and evacuate the unit.
Page 21
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr SCHEMATIC FOR ELECTRIC PUMP ON MODEL W 12volt systems BATTERY FUSE 15A A092819 Relay 12V See instruction E251002 Frigomatic Manuals 2007 PAGE 20...
Page 22
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr ELECTRICAL SCHEMATIC FOR FRIGOMATIC W 35F AND W50F 12/24 V WITH 1 PUMP AND PUMP INTERFACE E51385 FUSE 15A PUMP INTERFACE FOR FRIGOMATIC W35F—W50F BATTERY E51385 12 / 24 V FUSE Vedi schema See schematic R1219 A092819...
Page 23
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr ELECTRICAL SCHEMATIC FOR 2 OR 3 FRIGOMATIC W 35F AND W50F 12/24 V WITH 1 PUMP AND PUMP INTERFACE E51385 FUSE 15A PUMP INTERFACE BATTERY FOR FRIGOMATIC W35F—W50F E51385 12 / 24 V FUSE Vedi schema See schematic...
Page 24
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr SCHEMA DI COLLEGAMENTO PER FRIGOMATIC CON FUORISCAFO. SCHEMA DE CONNEXIONS POUR FRIGOMATIC AVEC ECHANGEUR DE COQUE. ISTALLATION LAYOUT FOR FRIGOMATIC WITH KEEL HEAT EXCHANGER. L = 2.8 m RED tag Repere ROUGE Blue tag– LOW Contrassegno ROSSO Repere Bleu–...
Page 25
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr SCHEMA DI COLLEGAMENTO PER SUPER FRIGOMATIC W 50F SCHEMA DE CONNEXIONS POUR SUPER FRIGOMATIC W50 F ISTALLATION LAYOUT FOR SUPER FRIGOMATIC W50 F cod. E51935 1 M—3 ft E51940 2 M—6 ft E51945 3 M—10 ft E51950 4 M—13 ft...
Page 26
FRIGOMATIC BD 35F INSTALLATION MANUAL Part Nr SCHEMA DI COLLEGAMENTO PER SUPER FRIGOMATIC W 50F SCHEMA DE CONNEXIONS POUR SUPER FRIGOMATIC W50 F ISTALLATION LAYOUT FOR SUPER FRIGOMATIC W50 F cod. E51920 1 M—3 ft E51940 2 M—6 ft E51945 3 M—10 ft E51950 4 M—13 ft...