AWILCO ENTIFFIC AIR 12V Diesel Service Manual

Parking heater

Advertisement

1.1.1 Service Manual
Doc. no.
: 01
Author
: MC
Improper installation of the Entiffic Heating System can cause fire, leakage of harmful carbon monoxide leading to
serious injury or death.
To install and maintain a Entiffic Heating System, professional expertise and technical documentation is necessary.
Special tools and equipment may also be necessary.
NEVER try to install or maintain a Entiffic Heating System, without prior training and experience with the Entiffic
heater series.
Carefully follow all instructions provided by Entiffic and this installation guide.
Entiffic rejects any liability for damage or problems caused by the product, if installed by untrained personnel or
against the instructions provided in the installation guide.
Revision
: Rev C
Approved by
:
Entiffic Air
Page
: 1 of 5
Rev. Date
: 28/6-2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ENTIFFIC AIR 12V Diesel and is the answer not in the manual?

Questions and answers

Summary of Contents for AWILCO ENTIFFIC AIR 12V Diesel

  • Page 1 1.1.1 Service Manual Doc. no. : 01 Revision : Rev C Page : 1 of 5 Author : MC Approved by Rev. Date : 28/6-2024 Entiffic Air Improper installation of the Entiffic Heating System can cause fire, leakage of harmful carbon monoxide leading to serious injury or death.
  • Page 2: Table Of Contents

    1.1.1 Service Manual Doc. no. : 01 Revision : Rev C Page : 2 of 5 Author : MC Approved by Rev. Date : 28/6-2024 1 Table of Contents Table of Contents ............................2 Software Service Mode ..........................3 Enter Service Mode ..........................3 Prime system with the pump while in service mode ................
  • Page 3: Software Service Mode

    1.1.1 Service Manual Doc. no. : 01 Revision : Rev C Page : 3 of 5 Author : MC Approved by Rev. Date : 28/6-2024 Valid for ENTIFFIC AIR, Software version 2.21 or higher 1 Software Service Mode In service mode the following points is available without extra components: ...
  • Page 4: Trim Fuel/Air Ratio While In Service Mode

    1.1.1 Service Manual Doc. no. : 01 Revision : Rev C Page : 4 of 5 Author : MC Approved by Rev. Date : 28/6-2024 2. Push “Heat” to stat pump. The pump state is not indicated by LED states. 3.
  • Page 5: Exit Service Mode

    1.1.1 Service Manual Doc. no. : 01 Revision : Rev C Page : 5 of 5 Author : MC Approved by Rev. Date : 28/6-2024 NB2: take care not to trim heater accidently during fuel priming. If accidental retrim occurs, use a CO-measuring instrument to trim heater to the following values.

This manual is also suitable for:

Entiffic air 12v methanolEair12dEair12m

Table of Contents